Eccentrically braced frames (EBFs) are desirable seismic load resisting systems as they combine the high elastic stiffness of concentrically braced frames with the ductility and stable energy dissipation of moment resisting frames. EBFs with links attached to the columns are particularly appealing for architectural flexibility as they provide multiple locations for placement of doors and hallways. However, previous research has shown that link-to-column connections are prone to failure at low drift levels, due to their susceptibility to fracture at the link flange-to-column welds. This paper investigates the application of the reduced beam section concept for links in eccentrically braced frames to enhance the ductility of link-to-column connections. A design procedure for link section reduction is proposed and preliminary finite-element analyses are conducted on a shear link with various reduced section geometries. A parametric study performed on an array of links having various cross sections and lengths suggests that the reduced link section may substantially reduce the plastic flange strains at the link ends, which can improve the fracture life. The reduction in plastic flange strains is found to be significant for all links, with larger reductions for intermediate and flexural links. Furthermore, the detrimental kinking deformation of the flanges, caused by the large rotation demands in shear links, is moved away from the column face when reduced sections were used. While the analysis results show promise, experimental verification is recommended before the proposed design procedure can be implemented in practice.
[1]
Taichiro Okazaki.
Seismic performanc of link-to-column connections in steel eccentrically braced frames
,
2004
.
[2]
Andrew J. Zekany,et al.
Experimental Investigation of Dogbone Moment Connections
,
1998
.
[3]
Michel Bruneau,et al.
Tubular Links for Eccentrically Braced Frames. I: Finite Element Parametric Study
,
2008
.
[4]
Ronald O. Hamburger,et al.
Prequalified Connections for Special and Intermediate Steel Moment Frames for Seismic Applications, ANSI/AISC 358-05
,
2006
.
[5]
Michael D. Engelhardt,et al.
Experimental Evaluation of Cyclically Loaded Reduced Beam Section Moment Connections
,
2002
.
[6]
Keiichiro Suita,et al.
Experimental Performance of Link-to-Column Connections in Eccentrically Braced Frames
,
2006
.
[7]
Chia-Ming Uang,et al.
Effect of Flange Width-Thickness Ratio on Eccentrically Braced Frames Link Cyclic Rotation Capacity
,
2005
.
[8]
Gregory G. Deierlein,et al.
Void Growth Model and Stress Modified Critical Strain Model to Predict Ductile Fracture in Structural Steels
,
2006
.
[9]
Sashi K. Kunnath,et al.
Effect of Local Details and Yield Ratio on Behavior of FR Steel Connections
,
2000
.
[10]
Egor P. Popov,et al.
General Behavior of WF Steel Shear Link Beams
,
1986
.