Developmental validation of a point-of-care, salivary α-amylase biosensor

The translation of salivary alpha-amylase (sAA) to the ambulatory assessment of stress hinges on the development of technologies capable of speedy and accurate reporting of sAA levels. Here, we describe the developmental validation and usability testing of a point-of-care, colorimetric, sAA biosensor. A disposable test strip allows for streamlined sample collection and a corresponding hand-held reader with integrated analytic capabilities permits rapid analysis and reporting of sAA levels. Bioanalytical validation utilizing saliva samples from 20 normal subjects indicates that, within the biosensor's linear range (10-230 U/ml), its accuracy (R(2)=0.989), precision (CV<9%), and measurement repeatability (range -3.1% to +3.1%) approach more elaborate laboratory-based, clinical analyzers. The truncated sampling-reporting cycle (<1 min) and the excellent performance characteristics of the biosensor has the potential to take sAA analysis out of the realm of dedicated, centralized laboratories and facilitate future sAA biomarker qualification studies.

[1]  Gerald A. Hudgens,et al.  Salivary α‐amylase as a measure of endogenous adrenergic activity , 1996 .

[2]  E. Gordis,et al.  Salivary alpha-amylase in biobehavioral research: recent developments and applications. , 2007, Annals of the New York Academy of Sciences.

[3]  M. Yamaguchi,et al.  Performance evaluation of salivary amylase activity monitor. , 2004, Biosensors & bioelectronics.

[4]  David Elashoff,et al.  The feasibility of ambulatory biosensor measurement of salivary alpha amylase: Relationships with self-reported and naturalistic psychological stress , 2011, Biological Psychology.

[5]  M. Navazesh,et al.  Methods for Collecting Saliva , 1993, Annals of the New York Academy of Sciences.

[6]  Nicolas Rohleder,et al.  Human salivary alpha-amylase reactivity in a psychosocial stress paradigm. , 2005, International journal of psychophysiology : official journal of the International Organization of Psychophysiology.

[7]  Jason A DeCaro Methodological considerations in the use of salivary α‐amylase as a stress marker in field research , 2008, American journal of human biology : the official journal of the Human Biology Council.

[8]  S. Haynes,et al.  Clinical assessment applications of ambulatory biosensors. , 2007, Psychological assessment.

[9]  C. Kirschbaum,et al.  Psychosocial Stress‐Induced Activation of Salivary Alpha‐Amylase: An Indicator of Sympathetic Activity? , 2004, Annals of the New York Academy of Sciences.

[10]  Yasufumi Mizuno,et al.  Hand-held monitor of sympathetic nervous system using salivary amylase activity and its validation by driver fatigue assessment. , 2006, Biosensors & bioelectronics.

[11]  U. Nater,et al.  Salivary alpha-amylase as a non-invasive biomarker for the sympathetic nervous system: Current state of research , 2009, Psychoneuroendocrinology.