A novel fluorescence lifetime imaging system that optimizes photon efficiency

Fluorescence lifetime imaging (FLIM) is a powerful microscopy technique for providing contrast of biological and other systems by differences in molecular species or their environments. However, the cost of equipment and the complexity of data analysis have limited the application of FLIM. We present a mathematical model and physical implementation for a low cost digital frequency domain FLIM (DFD‐FLIM) system, which can provide lifetime resolution with quality comparable to time‐correlated single photon counting methods. Our implementation provides data natively in the form of phasors. On the basis of the mathematical model, we present an error analysis that shows the precise parameters for maximizing the quality of lifetime acquisition, as well as data to support this conclusion. The hardware and software of the proposed DFD‐FLIM method simplifies the process of data acquisition for FLIM, presents a new interface for data display and interpretation, and optimizes the accuracy of lifetime determination. Microsc. Res. Tech., 2008. © 2007 Wiley‐Liss, Inc.

[1]  E Gratton,et al.  Resolution of mixtures of fluorophores using variable-frequency phase and modulation data. , 1984, Biophysical journal.

[2]  Hans C. Gerritsen,et al.  Fluorescence Lifetime Imaging in Scanning Microscopy , 2006 .

[3]  Axel Bergmann,et al.  Time‐correlated single photon counting FLIM: Some considerations for physiologists , 2007, Microscopy research and technique.

[4]  M A A Neil,et al.  Optically sectioned fluorescence lifetime imaging using a Nipkow disk microscope and a tunable ultrafast continuum excitation source. , 2005, Optics letters.

[5]  M. Tramier,et al.  Picosecond time‐resolved microspectrofluorometry in live cells exemplified by complex fluorescence dynamics of popular probes ethidium and cyan fluorescent protein , 2004, Journal of microscopy.

[6]  E. Gratton,et al.  A continuously variable frequency cross-correlation phase fluorometer with picosecond resolution. , 1983, Biophysical journal.

[7]  G. Weber,et al.  Resolution of the fluorescence lifetimes in a heterogeneous system by phase and modulation measurements , 1981 .

[8]  Enrico Gratton,et al.  Analysis of Heterogeneous Emissions by Multifrequency Phase and Modulation Fluorometry , 1983 .

[9]  S Pelet,et al.  A fast global fitting algorithm for fluorescence lifetime imaging microscopy based on image segmentation. , 2004, Biophysical journal.

[10]  R. D. Spencer,et al.  MEASUREMENTS OF SUBNANOSECOND FLUORESCENCE LIFETIMES WITH A CROSS‐CORRELATION PHASE FLUOROMETER * , 1969 .

[11]  J. Lakowicz,et al.  Analysis of fluorescence decay kinetics from variable-frequency phase shift and modulation data. , 1984, Biophysical journal.

[12]  John Safwat Eid Two-photon dual channel fluctuation correlation spectroscopy: Theory and application , 2002 .

[13]  Thomas M. Jovin,et al.  Time-resolved imaging fluorescence microscopy , 1992, Photonics West - Lasers and Applications in Science and Engineering.

[14]  R. Clegg,et al.  Polar Plot Representation for Frequency-Domain Analysis of Fluorescence Lifetimes , 2005, Journal of Fluorescence.

[15]  P. Verveer,et al.  Graphical representation and multicomponent analysis of single‐frequency fluorescence lifetime imaging microscopy data , 2004, Journal of microscopy.

[16]  J. Goedhart,et al.  Combination of a spinning disc confocal unit with frequency‐domain fluorescence lifetime imaging microscopy , 2007, Cytometry. Part A : the journal of the International Society for Analytical Cytology.

[17]  E. Gratton,et al.  The Measurement and Analysis of Heterogeneous Emissions by Multifrequency Phase and Modulation Fluorometry , 1984 .