Microwave imaging for monitoring breast cancer treatment: A pilot study.

BACKGROUND Microwave imaging has been proposed for medical applications, creating maps related to water content of tissues. Breast imaging has emerged as a key application because the signals can be coupled directly into the breast and experience limited attenuation in fatty tissues. While the literature contains reports of tumor detection with microwave approaches, there is limited exploration of treatment monitoring. PURPOSE This study aims to detect treatment-related changes in breast tissue with a low-resolution microwave scanner. METHODS Microwave scans of 15 patients undergoing treatment for early-stage breast cancer are collected at up to 4 time points: after surgery (baseline), 6 weeks after accelerated partial breast radiation, as well as 1 and 2 years post-treatment. Both the treated and untreated breast are scanned at each time point. The microwave scanner consists of planar transmit and receive arrays and uses signals from 0.1 to 10 GHz. The average microwave frequency properties (permittivity) are calculated for each scan to enable quantitative comparison. Baseline and 6-week results are analyzed with a two-way ANOVA with blocking. RESULTS Consistent properties are observed for the untreated breast over time, similar to a previous study. Comparison of the scans of the treated and untreated breast suggests increased properties related to treatment, particularly at baseline and 6-weeks following radiotherapy. Analysis of the average properties of the scans with ANOVA indicates statistically significant differences ( p < 0.05 $p < 0.05$ ) in the treated and untreated breast at these time points. CONCLUSIONS Microwave imaging has the potential to track treatment-related changes in breast tissues.

[1]  Declan O’Loughlin,et al.  Pathway to Demonstrating Clinical Efficacy of Microwave Breast Imaging: Qualitative and Quantitative Performance Assessment , 2022, IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology.

[2]  I. Akduman,et al.  Microwave Breast Lesion Classification - Results from Clinical Investigation of the SAFE Microwave Breast Cancer System. , 2022, Academic radiology.

[3]  M. Roumeliotis,et al.  Accelerated Partial Breast Irradiation (APBI) Using Five Daily Fractions: A Prospective, Phase II, Multi-Center Trial of Cosmetic Outcomes and Toxicity: Final Results , 2022, International Journal of Radiation Oncology*Biology*Physics.

[4]  T. Kikkawa,et al.  Feasibility of Portable Microwave Imaging Device for Breast Cancer Detection , 2021, Diagnostics.

[5]  M. Kerin,et al.  Automated Breast Lesion Detection and Characterization with the Wavelia Microwave Breast Imaging System: Methodological Proof-of-Concept on First-in-Human Patient Data , 2021, Applied Sciences.

[6]  X. Xiao,et al.  Microwave breast tumor localization using wavelet feature extraction and genetic algorithm-neural network. , 2021, Medical physics.

[7]  M. Kerin,et al.  Microwave Imaging in Breast Cancer - Results from the First-In-Human Clinical Investigation of the Wavelia System. , 2021, Academic radiology.

[8]  N. Ghavami,et al.  Breast lesion detection through MammoWave device: Empirical detection capability assessment of microwave images’ parameters , 2021, PloS one.

[9]  I. Akduman,et al.  SAFE: A Novel Microwave Imaging System Design for Breast Cancer Screening and Early Detection—Clinical Evaluation , 2021, Diagnostics.

[10]  M. Roumeliotis,et al.  Results of the ACCEL trial: Dosimetry in accelerated partial breast irradiation. , 2020, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[11]  Do-Hoon Kim,et al.  External beam accelerated partial breast irradiation versus whole breast irradiation after breast conserving surgery in women with ductal carcinoma in situ and node-negative breast cancer (RAPID): a randomised controlled trial , 2019, The Lancet.

[12]  M. Roumeliotis,et al.  One-Year Cosmesis and Fibrosis From ACCEL: Accelerated Partial Breast Irradiation (APBI) Using 27 Gy in 5 Daily Fractions. , 2019, Practical radiation oncology.

[13]  Hester F. Lingsma,et al.  Implementing Patient-Reported Outcome Measures in Clinical Breast Cancer Care: A Systematic Review. , 2019, Value in health : the journal of the International Society for Pharmacoeconomics and Outcomes Research.

[14]  R. Sidebottom,et al.  MARIA® M5: A multicentre clinical study to evaluate the ability of the Micrima radio-wave radar breast imaging system (MARIA®) to detect lesions in the symptomatic breast. , 2019, European journal of radiology.

[15]  M. Roumeliotis,et al.  Five-field IMRT class solutions and dosimetric planning guidelines for implementing accelerated partial breast irradiation. , 2017, Practical radiation oncology.

[16]  K. Paulsen,et al.  Microwave imaging for neoadjuvant chemotherapy monitoring: initial clinical experience , 2013, Breast Cancer Research.

[17]  Jennifer J. Gibson,et al.  Electromagnetic breast imaging: results of a pilot study in women with abnormal mammograms. , 2007, Radiology.

[18]  K. Paulsen,et al.  Initial clinical experience with microwave breast imaging in women with normal mammography. , 2007, Academic radiology.