Radiation dose reduction in pediatric CT-guided musculoskeletal procedures

BackgroundComputed-tomography-guided interventions are attractive for tissue sampling of pediatric bone lesions; however, it comes with exposure to ionizing radiation, inherent to CT and magnified by multiple passes during needle localization.ObjectiveWe evaluate a method of CT-guided bone biopsy that minimizes ionizing radiation exposure by lowering CT scanner tube current (mAs) and voltage (kVp) during each localization scan.Materials and methodsWe retrospectively reviewed all CT-guided bone biopsies (n = 13) over a 1-year period in 12 children. Three blinded readers identified the needle tip on the reduced-dose CT images (mAs = 50, kVp = 80) during the final localization scan at biopsy and rated the image quality as high, moderate or low.ResultsThe image quality of the reduced-dose scans during biopsy was rated as either high or moderate, with needle tip visualized in 12 out of 13 biopsies. Twelve of 13 biopsies also returned sufficient sample for a pathological diagnosis. The average savings in exposure using the dose-reduction technique was 87%.ConclusionOur results suggest that a low mAs and kVp strategy for needle localization during CT-guided bone biopsy yields a large dose reduction and produces acceptable image quality without sacrificing yield for biopsy diagnosis.

[1]  W. Ward,et al.  Fine Needle Aspiration Biopsy of Primary Bone Tumors , 2000, Clinical orthopaedics and related research.

[2]  R. Bell,et al.  [Radiofrequency treatment]. , 1997, Tidsskrift for den Norske laegeforening : tidsskrift for praktisk medicin, ny raekke.

[3]  Donald P. Frush,et al.  The ‘Image Gently’ campaign: increasing CT radiation dose awareness through a national education and awareness program , 2008, Pediatric Radiology.

[4]  L. Fayad,et al.  Multidetector CT of musculoskeletal disease in the pediatric patient: principles, techniques, and clinical applications. , 2005, Radiographics : a review publication of the Radiological Society of North America, Inc.

[5]  Charles Smith,et al.  Image-guided percutaneous biopsy of musculoskeletal lesions in children , 2007, Pediatric Radiology.

[6]  Apoorva Gogna,et al.  Image-guided musculoskeletal biopsy. , 2008, Radiologic clinics of North America.

[7]  J. S. Biermann,et al.  Accuracy of CT-guided percutaneous core needle biopsy for assessment of pediatric musculoskeletal lesions , 2011, Pediatric Radiology.

[8]  A. Huang,et al.  Musculoskeletal neoplasms: biopsy and intervention. , 2011, Radiologic clinics of North America.

[9]  D. Jaramillo,et al.  Multidetector row CT in pediatric musculoskeletal imaging , 2005, Pediatric Radiology.

[10]  U. Oyoyo,et al.  Ultra-low-dose protocol for CT-guided lung biopsies. , 2011, Journal of vascular and interventional radiology : JVIR.

[11]  C. Heyer,et al.  Evaluation of chronic infectious interstitial pulmonary disease in children by low-dose CT-guided transthoracic lung biopsy , 2005, European Radiology.

[12]  Keith J. Strauss,et al.  Image Gently, Step Lightly: increasing radiation dose awareness in pediatric interventional radiology , 2009, Pediatric Radiology.

[13]  E. Paulson,et al.  CT fluoroscopy--guided interventional procedures: techniques and radiation dose to radiologists. , 2001, Radiology.

[14]  H. Mankin,et al.  Accuracy of CT-guided needle biopsy of musculoskeletal neoplasms. , 1998, AJR. American journal of roentgenology.

[15]  P. Sundgren,et al.  Radiological and clinical outcome of screw placement in adolescent idiopathic scoliosis: evaluation with low-dose computed tomography , 2009, European Spine Journal.

[16]  Shuai Leng,et al.  Radiation dose levels for interventional CT procedures. , 2011, AJR. American journal of roentgenology.