Flexible, stretchable and implantable PDMS encapsulated cable for implantable medical device

PurposeDiverse commercial implantable medical devices were developed for the convenience and life-quality of patients, and tether-free diagnostics and therapeutics. Those devices need implantable cable, which connects each part of their devices for transcutaneous energy or signal transfer. For prolonged implantation into human body, it should be safe, robust, and be long-term operable without failure. In this paper, we introduce an implantable PDMS-coated cable.MethodsBy using PDMS as an encapsulation material, we developed a biocompatible, flexible and durable cable. Several tests were carried out for the evaluation of cable performance. Leakage test confirmed that coating using PDMS was sufficient to prevent the invasion of body fluid to conducting wire. Tensile test, torsion-durability test and bending-durability test demonstrated its mechanical durability and robustness to motion. The resistance variation recorded in the durability test was monitored to verify the electrical stability during movement of cable. Experiments of subcutaneous tissue implantation for 8 weeks were performed to observe the degree of biocompatibility as an implantable cable.Results & conclusionsOur cable was mechanically stable and biocompatible enough to be used for long term implantable medical devices.

[1]  Darryl Y Sasaki,et al.  Poly(dimethylsiloxane) thin films as biocompatible coatings for microfluidic devices: cell culture and flow studies with glial cells. , 2005, Journal of biomedical materials research. Part A.

[2]  P. E. K. Donaldson,et al.  The Cooper cable: an implantable multiconductor cable for neurological prostheses , 1983, Medical and Biological Engineering and Computing.

[3]  Bob Ward,et al.  In vivo biostability of polysiloxane polyether polyurethanes: resistance to metal ion oxidation. , 2006, Journal of biomedical materials research. Part A.

[4]  Victor Parsonnet,et al.  Long‐Term Structural Failure of Coaxial Polyurethane Implantable Cardioverter Defibrillator Leads , 2002, Pacing and clinical electrophysiology : PACE.

[5]  T. V. van Kooten,et al.  In vitro degradation of a biodegradable polyurethane foam, based on 1,4-butanediisocyanate: a three-year study at physiological and elevated temperature. , 2009, Journal of biomedical materials research. Part A.

[6]  James M. Anderson,et al.  In vivo biostability of polyether polyurethanes with fluoropolymer and polyethylene oxide surface modifying endgroups; resistance to metal ion oxidation. , 2007, Journal of biomedical materials research. Part A.

[7]  Tim Vaughn,et al.  Detection and management of an implantable cardioverter defibrillator lead failure: incidence and clinical implications. , 2003, Journal of the American College of Cardiology.

[8]  Joong Yull Park,et al.  Increased poly(dimethylsiloxane) stiffness improves viability and morphology of mouse fibroblast cells , 2010 .

[9]  M Szycher,et al.  In vivo Testing of a Biostable Polyurethane , 1991, Journal of biomaterials applications.

[10]  Sylwester Gogolewski,et al.  Preparation, degradation, and calcification of biodegradable polyurethane foams for bone graft substitutes. , 2003, Journal of biomedical materials research. Part A.

[11]  Thomas Kleemann,et al.  Annual Rate of Transvenous Defibrillation Lead Defects in Implantable Cardioverter-Defibrillators Over a Period of >10 Years , 2007, Circulation.

[12]  Michael Sacks,et al.  Prevention of oxidative degradation of polyurethane by covalent attachment of di-tert-butylphenol residues. , 2006, Journal of biomedical materials research. Part A.

[13]  Feng Xu,et al.  Degradation Behavior and Biocompatibility of PEG/PANI-Derived Polyurethane Co-polymers , 2010, Journal of biomaterials science. Polymer edition.

[14]  B Stegenga,et al.  A long-term in vitro biocompatibility study of a biodegradable polyurethane and its degradation products. , 2006, Journal of biomedical materials research. Part A.

[15]  M. Bélanger,et al.  Hemocompatibility, biocompatibility, inflammatory and in vivo studies of primary reference materials low-density polyethylene and polydimethylsiloxane: a review. , 2001, Journal of biomedical materials research.

[16]  Wataru Shimizu,et al.  Long-term follow-up of transvenous defibrillation leads: high incidence of fracture in coaxial polyurethane lead. , 2006, Circulation journal : official journal of the Japanese Circulation Society.

[17]  Robert J Levy,et al.  Prevention of polyurethane oxidative degradation with phenolic antioxidants covalently attached to the hard segments: structure-function relationships. , 2010, Journal of biomedical materials research. Part A.