Long-term implantable glucose biosensors

Summary Long-term implantable glucose sensors with a demonstrated lifetime of at least two weeks play a key role in continuous glucose monitoring (CGM) and the development of closed-loop artificial pancreas systems for the emerging number of diabetes patients. This short review summarises the current state of the art of CGM systems and points out specific limitations of amperometric glucose biosensors regarding their inherent sensor long-term and signal stability that are mainly caused by the inevitable foreign body response after sensor implantation.

[1]  Karl Cammann,et al.  Bio-sensors based on ion-selective electrodes , 1977 .

[2]  Yan Wang,et al.  Foreign Body Reaction to Implantable Biosensors , 2015, Journal of diabetes science and technology.

[3]  Adam Heller,et al.  Electrical Wiring of Redox Enzymes , 1990 .

[4]  J. Gooding,et al.  Approaches Toward Allowing Electroanalytical Devices to be Used in Biological Fluids , 2014 .

[5]  Joseph Wang,et al.  Glucose Biosensors : 40 Years of Advances and Challenges , 2001 .

[6]  L. Gorton,et al.  Cellobiose dehydrogenase: a versatile catalyst for electrochemical applications. , 2010, Chemphyschem : a European journal of chemical physics and physical chemistry.

[7]  BasuAnanda,et al.  Direct Evidence of Acetaminophen Interference with Subcutaneous Glucose Sensing in Humans: A Pilot Study , 2016 .

[8]  Joseph Wang Electrochemical glucose biosensors. , 2008, Chemical reviews.

[9]  T. Bailey,et al.  The Performance and Usability of a Factory-Calibrated Flash Glucose Monitoring System , 2015, Diabetes technology & therapeutics.

[10]  J. Hans DeVries,et al.  Accuracy and Longevity of an Implantable Continuous Glucose Sensor in the PRECISE Study: A 180-Day, Prospective, Multicenter, Pivotal Trial , 2016, Diabetes Care.

[11]  G. S. Wilson,et al.  Can continuous glucose monitoring be used for the treatment of diabetes. , 1992, Analytical chemistry.

[12]  L. Gorton,et al.  Recombinantly produced cellobiose dehydrogenase from Corynascus thermophilus for glucose biosensors and biofuel cells. , 2012, Biotechnology journal.

[13]  P. Bartlett,et al.  There is no evidence to support literature claims of direct electron transfer (DET) for native glucose oxidase (GOx) at carbon nanotubes or graphene , 2017, Journal of Electroanalytical Chemistry.

[14]  David Talens-Perales,et al.  Identification and Structural Analysis of Amino Acid Substitutions that Increase the Stability and Activity of Aspergillus niger Glucose Oxidase , 2015, PloS one.

[15]  G. S. Wilson,et al.  Calibration of a subcutaneous amperometric glucose sensor. Part 1. Effect of measurement uncertainties on the determination of sensor sensitivity and background current. , 2002, Biosensors & bioelectronics.

[16]  Sandro Carrara,et al.  Implantable enzyme amperometric biosensors. , 2012, Biosensors & bioelectronics.

[17]  T. Bailey,et al.  Clinical Accuracy of a Continuous Glucose Monitoring System With an Advanced Algorithm , 2014, Journal of diabetes science and technology.

[18]  L. C. Clark,et al.  ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY , 1962 .

[19]  N. Mano,et al.  Designing a highly active soluble PQQ-glucose dehydrogenase for efficient glucose biosensors and biofuel cells. , 2010, Biochemical and biophysical research communications.

[20]  F. Sturm,et al.  253 - Development of an Implantable Electrocatalytic Glucose Sensor , 1978 .

[21]  Plamen Atanasov,et al.  Enzyme‐catalyzed direct electron transfer: Fundamentals and analytical applications , 1997 .

[22]  Shoji Takeuchi,et al.  Towards Smart Tattoos: Implantable Biosensors for Continuous Glucose Monitoring , 2013, Advanced healthcare materials.

[23]  R. Bonnecaze,et al.  Measurement and modeling of the transient difference between blood and subcutaneous glucose concentrations in the rat after injection of insulin. , 1998, Proceedings of the National Academy of Sciences of the United States of America.

[24]  Thomas Peyser,et al.  A new-generation continuous glucose monitoring system: improved accuracy and reliability compared with a previous-generation system. , 2013, Diabetes technology & therapeutics.

[25]  M. Meyerhoff,et al.  Nitric Oxide Release for Improving Performance of Implantable Chemical Sensors - A Review. , 2017, Applied materials today.

[26]  J. A. Hubbell,et al.  Surface Treatments of Polymers for Biocompatibility , 1996 .

[27]  Y. Yamasaki,et al.  WEARABLE ARTIFICIAL ENDOCRINE PANCREAS WITH NEEDLE-TYPE GLUCOSE SENSOR , 1982, The Lancet.

[28]  Yingchun Fu,et al.  Recent advances in electrochemical glucose biosensors: a review , 2013 .

[29]  J. V. Bannister,et al.  Amperometric biosensors. , 1990, Journal of biotechnology.

[30]  J. Hans DeVries,et al.  Continuous Glucose Monitoring, Future Products, and Update on Worldwide Artificial Pancreas Projects. , 2016, Diabetes technology & therapeutics.

[31]  P. D'Orazio Biosensors in clinical chemistry. , 2003, Clinica chimica acta; international journal of clinical chemistry.

[32]  Shengfu Chen,et al.  Antifouling Zwitterionic Coating via Electrochemically Mediated Atom Transfer Radical Polymerization on Enzyme-Based Glucose Sensors for Long-Time Stability in 37 °C Serum. , 2016, Langmuir : the ACS journal of surfaces and colloids.

[33]  John J Mastrototaro,et al.  Subcutaneous glucose predicts plasma glucose independent of insulin: implications for continuous monitoring. , 1999, American journal of physiology. Endocrinology and metabolism.

[34]  W. Schuhmann,et al.  Controlling the charge of pH-responsive redox hydrogels by means of redox-silent biocatalytic processes. A biocatalytic off/on switch , 2015 .

[35]  Yuhua Zhao,et al.  Significant improvement of thermal stability of glucose 1-dehydrogenase by introducing disulfide bonds at the tetramer interface. , 2013, Enzyme and microbial technology.

[36]  Frances H Arnold,et al.  Modification of Galactose Oxidase to Introduce Glucose 6‐Oxidase Activity , 2002, Chembiochem : a European journal of chemical biology.

[37]  Giovanni Sparacino,et al.  “Smart” Continuous Glucose Monitoring Sensors: On-Line Signal Processing Issues , 2010, Sensors.

[38]  E M Lonsdale,et al.  A telemetering system for securing data on the motility of internal organs. , 1966, IEEE transactions on bio-medical engineering.

[39]  Adam Heller,et al.  Electrochemistry in diabetes management. , 2010, Accounts of chemical research.

[40]  K. Ward,et al.  Electrochemical properties of nanostructured porous gold electrodes in biofouling solutions. , 2013, Analytical chemistry.

[41]  D. Klonoff The Benefits of Implanted Glucose Sensors , 2007, Journal of diabetes science and technology.

[42]  Ronald Brazg,et al.  Accuracy of a Fourth-Generation Subcutaneous Continuous Glucose Sensor , 2017, Diabetes technology & therapeutics.

[43]  Wolfgang Schuhmann,et al.  Amperometric enzyme biosensors based on optimised electron-transfer pathways and non-manual immobilisation procedures. , 2002, Journal of biotechnology.

[44]  Angela Spanu,et al.  Enzyme Biosensors for Biomedical Applications: Strategies for Safeguarding Analytical Performances in Biological Fluids , 2016, Sensors.

[45]  R. Marcus,et al.  Electron transfers in chemistry and biology , 1985 .

[46]  N. Mano,et al.  Oxygen reduction on redox mediators may affect glucose biosensors based on “wired” enzymes , 2012 .

[47]  Allen J. Bard,et al.  Electrochemical Methods: Fundamentals and Applications , 1980 .

[48]  G. S. Wilson,et al.  Native glucose oxidase does not undergo direct electron transfer. , 2016, Biosensors & bioelectronics.

[49]  Ronald Brazg,et al.  FreeStyle Navigator Continuous Glucose Monitoring System with TRUstart Algorithm, a 1-Hour Warm-up Time , 2011, Journal of diabetes science and technology.

[50]  W. Schuhmann,et al.  Design of an Os Complex-Modified Hydrogel with Optimized Redox Potential for Biosensors and Biofuel Cells. , 2016, Chemistry.

[51]  A. Ruff,et al.  Redox polymers in bioelectrochemistry: Common playgrounds and novel concepts , 2017 .

[52]  Ronald Brazg,et al.  Accuracy and acceptability of the 6-day Enlite continuous subcutaneous glucose sensor. , 2014, Diabetes technology & therapeutics.

[53]  L. Gorton,et al.  Cellobiose dehydrogenase: Insights on the nanostructuration of electrodes for improved development of biosensors and biofuel cells , 2017 .

[54]  J. A. Hubbell,et al.  Design, characterization, and one-point in vivo calibration of a subcutaneously implanted glucose electrode. , 1994, Analytical chemistry.

[55]  Andrew DeHennis,et al.  Performance characterization of an abiotic and fluorescent-based continuous glucose monitoring system in patients with type 1 diabetes. , 2014, Biosensors & bioelectronics.

[56]  Irl B. Hirsch,et al.  Clinical review: Realistic expectations and practical use of continuous glucose monitoring for the endocrinologist. , 2009, The Journal of clinical endocrinology and metabolism.

[57]  Zhigang Zhu,et al.  Current and Emerging Technology for Continuous Glucose Monitoring , 2017, Sensors.

[58]  Giovanni Sparacino,et al.  Wearable Continuous Glucose Monitoring Sensors: A Revolution in Diabetes Treatment , 2017 .

[59]  Fotios Papadimitrakopoulos,et al.  Biomaterials/Tissue Interactions: Possible Solutions to Overcome Foreign Body Response , 2010, The AAPS Journal.