A basic study of some normoxic polymer gel dosimeters.

Polymer gel dosimeters offer a wide range of potential applications in the three-dimensional verification of complex dose distribution such as in intensity-modulated radiotherapy (IMRT). Until now, however, polymer gel dosimeters have not been widely used in the clinic. One of the reasons is that they are difficult to manufacture. As the polymerization in polymer gels is inhibited by oxygen, all free oxygen has to be removed from the gels. For several years this was achieved by bubbling nitrogen through the gel solutions and by filling the phantoms in a glove box that is perfused with nitrogen. Recently another gel formulation was proposed in which oxygen is bound in a metallo-organic complex thus removing the problem of oxygen inhibition. The proposed gel consists of methacrylic acid, gelatin, ascorbic acid, hydroquinone and copper(II)sulphate and is given the acronym MAGIC gel dosimeter. These gels are fabricated under normal atmospheric conditions and are therefore called 'normoxic' gel dosimeters. In this study, a chemical analysis on the MAGIC gel was performed. The composition of the gel was varied and its radiation response was evaluated. The role of different chemicals and the reaction kinetics are discussed. It was found that ascorbic acid alone was able to bind the oxygen and can thus be used as an anti-oxidant in a polymer gel dosimeter. It was also found that the anti-oxidants N-acetyl-cysteine and tetrakis(hydroxymethyl)phosphonium were effective in scavenging the oxygen. However, the rate of oxygen scavenging is dependent on the anti-oxidant and its concentration with tetrakis(hydroxymethyl)phosphonium being the most reactive anti-oxidants. Potentiometric oxygen measurements in solution provide an easy way to get a first impression on the rate of oxygen scavenging. It is shown that cupper(II)sulphate operates as a catalyst in the oxidation of ascorbic acid. We, therefore, propose some new normoxic gel formulations that have a less complicated chemical formulation than the MAGIC gel.

[1]  C. D. Wagter,et al.  Artefacts in multi-echo T2 imaging for high-precision gel dosimetry: III. Effects of temperature drift during scanning. , 2001 .

[2]  A. Sarac,et al.  Electrochemically induced redox polymerization of acrylamide , 1999 .

[3]  Oxygen‐ascorbic acid‐Copper(II) initiating system. A kinetic study of the polymerisation of methyl acrylate in aqueous medium , 1982 .

[4]  W. Brittin,et al.  Nuclear Magnetic Resonance Studies in Multiple Phase Systems: Lifetime of a Water Molecule in an Adsorbing Phase on Silica Gel , 1957 .

[5]  C. Baldock,et al.  The relationship between radiation-induced chemical processes and transverse relaxation times in polymer gel dosimeters. , 2001, Physics in medicine and biology.

[6]  Rik Van de Walle,et al.  Mathematical analysis and experimental investigation of noise in quantitative magnetic resonance imaging applied in polymer gel dosimetry , 1998, Signal Process..

[7]  J. Gore,et al.  Polymer gels for magnetic resonance imaging of radiation dose distributions at normal room atmosphere. , 2001, Physics in medicine and biology.

[8]  C. Gopinathan,et al.  Radiation Induced Polymerization of N,N'-Methylenebisacrylamide in Aqueous Solution , 1997 .

[9]  C. De Wagter,et al.  On the accuracy of monomer/polymer gel dosimetry in the proximity of a high-dose-rate 192Ir source. , 2001, Physics in medicine and biology.

[10]  A. Martell,et al.  Metal ion and metal chelate catalyzed oxidation of ascorbic acid by molecular oxygen. II. Cupric and ferric chelate catalyzed oxidation. , 1967, Journal of the American Chemical Society.

[11]  C De Wagter,et al.  An investigation of the chemical stability of a monomer/polymer gel dosimeter. , 2000, Physics in medicine and biology.

[12]  C. Baldock,et al.  Dose resolution optimization of polymer gel dosimeters using different monomers. , 2001, Physics in medicine and biology.

[13]  Reactions of Hydrated Electron with N,N′-Methylenebisacrylamide in Aqueous Solution: A Pulse Radiolysis Study , 1995 .

[14]  E. Meyer,et al.  Photofragmentation of Epoxides. IV. Precursors for Phenylcyanocarbene , 1967 .

[15]  J. Gore,et al.  NMR relaxation enhancement in gels polymerized and cross-linked by ionizing radiation: a new approach to 3D dosimetry by MRI. , 1993, Magnetic resonance imaging.

[16]  K. V. Rao,et al.  Polymerization of methyl methacrylate in the presence of molecular oxygen — a kinetic study , 1981 .

[17]  L J Schreiner,et al.  Multiple-site fast exchange model for spin-lattice relaxation in the Fricke-gelatin dosimeter. , 1997, Medical physics.

[18]  Y. Shimazu,et al.  A comparison of scavenging abilities of antioxidants against hydroxyl radicals. , 1996, Archives of biochemistry and biophysics.