Simultaneous preconcentration and determination of copper, nickel, cobalt and lead ions content by flame atomic absorption spectrometry.

A sensitive and simple method for the simultaneous preconcentration of nutritionally important minerals in real samples has been reported. The method is based on the formation of metal complexes by 4,6-dihydroxy-2-mercaptopyrimidine (DHMP) loaded on activated carbon. The metals content on the complexes are then eluted using 5 mL 2M HNO(3) in acetone, which are detected by AAS at resonance line. In this procedure, minerals such as Cu, Ni, Pb and Co could be analyzed in one run by caring out the simultaneous separation and quantification of them. At optimum condition the response are linear over concentration range of 0.04-1.1 microg mL(-1) for Ni(2+) and 0.04-1.0 microg mL(-1) for Cu(2+), Pb(2+) and Co(2+). The detection limits of each element are expressed as the amount of analytes in ng mL(-1) giving a signal to noise ratio of 3 are equal to 3.5, 3.4, 2.9 and 8.4 for Ni(2+), Co(2+), Cu(2+) and Pb(2+). The sorption capacity was determined by saturating 0.5 g solid phase. The loading capacity are 0.54, 0.53, 0.63 and 0.45 mg g(-1) for Ni(2+), Co(2+), Cu(2+) and Pb(2+). The ability of method for repeatable recovery of trace ion are 99.0, 98.9, 99.2 and 98.8 with R.S.D. of 1.4, 1.3, 1.2 and 1.4 for Ni(2+), Co(2+), Cu(2+) and Pb(2+). The low detection limits of these elements in this technique make it a superior alternative to UV-vis and in several applications, also an alternative to ICP-MS techniques. The method has been successfully applied for these metals content evaluation in some real samples including natural water, leaves of spinach and cow liver.

[1]  E. Piperaki,et al.  Investigations on the sorption of metal chelates on activated carbon , 1978 .

[2]  M. Valcárcel,et al.  Preconcentration and atomic absorption determination of copper traces in waters by on-line adsorption-elution on an activated carbon minicolumn. , 1994, Talanta.

[3]  S. Ferreira,et al.  Nickel determination in saline matrices by ICP-AES after sorption on Amberlite XAD-2 loaded with PAN. , 1999, Talanta: The International Journal of Pure and Applied Analytical Chemistry.

[4]  Krzysztof Jankowski,et al.  Multielement determination of heavy metals in water samples by continuous powder introduction microwave-induced plasma atomic emission spectrometry after preconcentration on activated carbon ☆ , 2005 .

[5]  M. Soylak,et al.  Determination of trace metal ions by AAS in natural water samples after preconcentration of pyrocatechol violet complexes on an activated carbon column. , 2000, Talanta.

[6]  V. Dressler,et al.  Determination of copper, cadmium, lead, bismuth and selenium(iv) in sea-water by electrothermal vaporization inductively coupled plasma mass spectrometry after on-line separation , 1998 .

[7]  A. Safavi,et al.  Spectrophotometric Study of the Stabilities of Copper, Zinc, Nickel and Cobalt Complexes with 1,2-Bis-methyl(2-aminocyclopentene carbodithioate)ethane in Binary N,N-Dimethyl Formamide Dichloromethane Mixtures , 1999 .

[8]  M. Ghaedi,et al.  Simultaneous Preconcentration and Determination of Copper, Nickel, Cobalt, Lead, and Iron Content Using a Surfactant-Coated Alumina , 2006 .

[9]  M. Soylak,et al.  Atomic absorption spectrometric determination of copper, cobalt, cadmium, lead, nickel and chromium in table salt samples after preconcentration on activated carbon , 2001 .

[10]  M. Ghaedi,et al.  Preconcentration and Extraction of Copper on Activated Carbon Using 4-Amino-2, 3-dimethyl-1-phenyl-3-pyrazoline or 4-(4-methoxybenzylidenimin) thiophenole , 2006 .

[11]  Luis D. Martinez,et al.  On-line preconcentration/determination of cadmium in drinking water on activated carbon using 8-hydroxyquinoline in a flow injection system coupled to an inductively coupled plasma optical emission spectrometer , 2003 .

[12]  R. Rangaswamy,et al.  Sorption of PAR–metal complexes on activated carbon as a rapid preconcentration method for the determination of Cu, Co, Cd, Cr, Ni, Pb and V in ground water , 1998 .

[13]  H. Onishi,et al.  Adsorption of metal ions on activated carbon from aqueous solutions at pH 1-13. , 1986, Talanta.

[14]  M. Soylak,et al.  Column Preconcentration of Trace Amounts of Copper on Activated Carbon from Natural Water Samples , 1996 .

[15]  L. Martínez,et al.  On-line preconcentration/determination of copper in parenteral solutions using activated carbon by inductively coupled plasma optical emission spectrometry. , 2005, Journal of pharmaceutical and biomedical analysis.

[16]  A. Imyim,et al.  Multi-element preconcentration of heavy metal ions from aqueous solution by APDC impregnated activated carbon. , 2005, Talanta.

[17]  L. Martínez,et al.  On-line preconcentration of cobalt in drinking water using a minicolumn packed with activated carbon coupled to electrothermal atomic absorption spectrometric determination , 2003 .

[18]  M. Soylak,et al.  Trace Enrichment and Atomic Absorption Spectrometric Determination of Lead, Copper, Cadmium and Nickel in Drinking Water Samples by Use of an Activated Carbon Column , 1997 .

[19]  A. Siripinyanond,et al.  Determination of Cd, Co, Hg, and Ni in seawater after enrichment on activated carbon by slurry sampling electrothermal AAS , 2000 .

[20]  J. Chen,et al.  Surface charge and metal ion adsorption on an H-type activated carbon: experimental observation and modeling simulation by the surface complex formation approach , 2001 .

[21]  M. Ghaedi,et al.  Highly Selective and Sensitive Preconcentration of Mercury Ion and Determination by Cold Vapor Atomic Absorption Spectroscopy , 2006 .