Online surge testing applied to an induction machine with emulated insulation breakdown

A breakdown of the electrical insulation system can cause catastrophic failure of the electrical machine and bring large process downtime losses. Preventive maintenance and online monitoring are some of the methods to improve reliability and reduce unscheduled downtime. One of the main reasons for the failure is the breakdown of the stator insulation. The offline surge test is the most commonly used offline test to assess the condition of the turn insulation. There is no online monitoring method that is applicable to low voltage machines and has the same capabilities as the surge test. This paper shows how to conduct a surge test online. The required hardware and the test procedures are described. A new test setup that emulates the arcing due to a weak turn insulation is used to validate the technique proposed.

[1]  G.C. Stone,et al.  Electrical insulation for rotating machines-design, evaluation, aging, testing, and repair - Book Review , 2004, IEEE Electrical Insulation Magazine.

[2]  R. G. Harley,et al.  Sensitivity analysis of the surge test applied to AC machines , 2011, 2011 IEEE International Electric Machines & Drives Conference (IEMDC).

[3]  R. G. Harley,et al.  Experimental emulation of stator turn insulation breakdown during a surge test , 2011, 2011 IEEE International Electric Machines & Drives Conference (IEMDC).

[4]  Xianghui Huang,et al.  Detection of Rotor Eccentricity Faults in a Closed-Loop Drive-Connected Induction Motor Using an Artificial Neural Network , 2007, IEEE Transactions on Power Electronics.

[5]  Bin Lu,et al.  Investigation on surge testing for winding insulation fault detection in an online environment , 2009, 2009 IEEE Energy Conversion Congress and Exposition.

[6]  A. Savitzky,et al.  Smoothing and Differentiation of Data by Simplified Least Squares Procedures. , 1964 .

[7]  Stefan Grubic Online monitoring of turn insulation deterioration in mains-fed induction machines using online surge testing , 2011 .

[8]  E. Wiedenbrug,et al.  Impulse testing as a predictive maintenance tool , 2003, 4th IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives, 2003. SDEMPED 2003..

[9]  Thomas G. Habetler,et al.  A Survey on Testing and Monitoring Methods for Stator Insulation Systems of Low-Voltage Induction Machines Focusing on Turn Insulation Problems , 2008, IEEE Transactions on Industrial Electronics.

[10]  Thomas G. Habetler,et al.  A new concept for online surge testing for the detection of winding insulation deterioration , 2010, 2010 IEEE Energy Conversion Congress and Exposition.