Characterization of an Adult Mock Circulation for Testing Cardiac Support Devices

A need exists for a mock circulation that behaves in a physiologic manner for testing cardiac devices in normal and pathologic states. To address this need, an integrated mock cardiovascular system consisting of an atrium, ventricle, and systemic and coronary vasculature was developed specifically for testing ventricular assist devices (VADs). This test configuration enables atrial or ventricular apex inflow and aortic outflow cannulation connections. The objective of this study was to assess the ability of the mock ventricle to mimic the Frank–Starling response of normal, heart failure, and cardiac recovery conditions. The pressure–volume relationship of the mock ventricle was evaluated by varying ventricular volume over a wide range via atrial (preload) and aortic (afterload) occlusions. The input impedance of the mock vasculature was calculated using aortic pressure and flow measurements and also was used to estimate resistance, compliance, and inertial mechanical properties of the circulatory system. Results demonstrated that the mock ventricle pressure–volume loops and the end diastolic and end systolic pressure–volume relationships are representative of the Starling characteristics of the natural heart for each of the test conditions. The mock vasculature can be configured to mimic the input impedance and mechanical properties of native vasculature in the normal state. Although mock circulation testing systems cannot replace in vivo models, this configuration should be well suited for developing experimental protocols, testing device feedback control algorithms, investigating flow profiles, and training surgical staff on the operational procedures of cardiovascular devices.

[1]  John E. Hall,et al.  Textbook of Medical Physiology 11th ed. , 2006 .

[2]  R. D. Latham,et al.  Isolated aorta setup for hemodynamic studies , 2006, Annals of Biomedical Engineering.

[3]  Daniel L. Ewert,et al.  HEART: an automated beat-to-beat cardiovascular analysis package using Matlab® , 2004, Comput. Biol. Medicine.

[4]  J. F. Antaki,et al.  Elastance-Based Control of a Mock Circulatory System , 2001, Annals of Biomedical Engineering.

[5]  S. Koenig,et al.  Fast Estimation of Arterial Vascular Parameters for Transient and Steady Beats with Application to Hemodynamic State under Variant Gravitational Conditions , 1999, Annals of Biomedical Engineering.

[6]  S. Koenig,et al.  Uncertainty analysis of measurement error in calculating vascular input impedance: how many harmonics can be resolved? , 2002, Proceedings of the Second Joint 24th Annual Conference and the Annual Fall Meeting of the Biomedical Engineering Society] [Engineering in Medicine and Biology.

[7]  Maciej Kozarski,et al.  A Hybrid Mock Circulatory System: Testing a Prototype Under Physiologic and Pathological Conditions , 2002, ASAIO journal.

[8]  C De Lazzari,et al.  A Hybrid (Numerical-physical) Model of the Left Ventricle , 2001, The International journal of artificial organs.

[9]  P Segers,et al.  Hydrodynamic Characterisation of Ventricular Assist Devices , 2001, The International journal of artificial organs.

[10]  D. Burkhoff,et al.  Time course of reverse remodeling of the left ventricle during support with a left ventricular assist device. , 2001, The Journal of thoracic and cardiovascular surgery.

[11]  F. Clemente,et al.  A Physical Model of the Human Systemic Arterial Tree , 2000, The International journal of artificial organs.

[12]  M C Oz,et al.  Left ventricular assist device-induced reverse ventricular remodeling. , 2000, Progress in cardiovascular diseases.

[13]  M K Sharp,et al.  Development of a hydraulic model of the human systemic circulation. , 1999, ASAIO journal.

[14]  J. D. Schaub,et al.  Development of a flow feedback pulse duplicator system with rhesus monkey arterial input impedance characteristics. , 1999 .

[15]  R. Dowling,et al.  Intraoperative Assessment of Acute Hemodynamic Changes After Partial Left Ventriculectomy , 1999, Journal of cardiac surgery.

[16]  N. Stergiopulos,et al.  Total arterial inertance as the fourth element of the windkessel model. , 1999, American journal of physiology. Heart and circulatory physiology.

[17]  J. Thibault,et al.  A continuous and pulsatile flow circulation system for evaluation of cardiovascular devices. , 1998, Artificial organs.

[18]  John G. Wood,et al.  MCDONALDʼS BLOOD FLOW IN ARTERIES: THEORETICAL, EXPERIMENTAL AND CLINICAL PRINCIPLES, 4TH EDITION , 1998 .

[19]  M. Sharp,et al.  Compact Compliance Chamber Design for the Study of Cardiac Performance in Microgravity , 1997, ASAIO journal.

[20]  Gill B. Bearnson,et al.  LEFT VENTRICULAR SIMULATOR FOR CARDIOVASCULAR DEVICE TESTING , 1996 .

[21]  M C Oz,et al.  Reversal of chronic ventricular dilation in patients with end-stage cardiomyopathy by prolonged mechanical unloading. , 1995, Circulation.

[22]  G Ferrari,et al.  Mock circulatory system for in vitro reproduction of the left ventricle, the arterial tree and their interaction with a left ventricular assist device. , 1994, Journal of medical engineering & technology.

[23]  D B Geselowitz,et al.  A new mock circulatory loop and its application to the study of chemical additive and aortic pressure effects on hemolysis in the Penn State electric ventricular assist device. , 1994, Artificial organs.

[24]  K. C. Watts,et al.  Hydrodynamic simulation of arterial networks which include compliant and rigid bypass grafts. , 1994, Journal of biomechanics.

[25]  Ventricular/vascular interaction in health and heart failure. , 1992 .

[26]  E Wolner,et al.  A Modular Mock Circulation for Hydromechanical Studies on Valves, Stenoses, Vascular Grafts and Cardiac Assist Devices , 1992, The International journal of artificial organs.

[27]  H Reul,et al.  Compact Mock Loops of the Systemic and Pulmonary Circulation for Blood Pump Testing , 1992, The International journal of artificial organs.

[28]  W. Nichols,et al.  Ventricular/vascular interaction in health and heart failure. , 1992, Comprehensive therapy.

[29]  R. Applegate,et al.  Cardiac Contraction and the Pressure-Volume Relationship , 1990 .

[30]  E Wolner,et al.  Mechanical simulation of shear stress on the walls of peripheral arteries. , 1990, Journal of biomechanics.

[31]  G. Pantalos,et al.  Characterization of natural and total artificial heart acceleration. , 1989, ASAIO transactions.

[32]  D. Wurzel,et al.  Development of Smaller Artificial Ventricles and Valves Made by Vacuum Forming , 1988, The International journal of artificial organs.

[33]  L N Scotten,et al.  In vitro assessment of mitral valve prostheses. , 1980, The Journal of thoracic and cardiovascular surgery.

[34]  E A Geiser,et al.  Vascular load defined by the aortic input impedance spectrum. , 1980, Federation proceedings.

[35]  L N Scotten,et al.  Construction and evaluation of a hydromechanical simulation facility for the assessment of mitral valve prostheses. , 1979, Journal of medical engineering & technology.

[36]  W. Nichols,et al.  Aortic Input Impedance in Heart Failure , 1978, Circulation.

[37]  W E Walker,et al.  Input Impedance of the Systemic Circulation in Man , 1977, Circulation research.

[38]  J F Cornhill,et al.  An aortic--left ventricular pulse duplicator used in testing prosthetic aortic heart valves. , 1977, The Journal of thoracic and cardiovascular surgery.