Constructing spherical panoramas of a bladder phantom from endoscopic video using bundle adjustment

The high recurrence rate of bladder cancer requires patients to undergo frequent surveillance screenings over their lifetime following initial diagnosis and resection. Our laboratory is developing panoramic stitching software that would compile several minutes of cystoscopic video into a single panoramic image, covering the entire bladder, for review by an urolgist at a later time or remote location. Global alignment of video frames is achieved by using a bundle adjuster that simultaneously recovers both the 3D structure of the bladder as well as the scope motion using only the video frames as input. The result of the algorithm is a complete 360° spherical panorama of the outer surface. The details of the software algorithms are presented here along with results from both a virtual cystoscopy as well from real endoscopic imaging of a bladder phantom. The software successfully stitched several hundred video frames into a single panoramic with subpixel accuracy and with no knowledge of the intrinsic camera properties, such as focal length and radial distortion. In the discussion, we outline future work in development of the software as well as identifying factors pertinent to clinical translation of this technology.

[1]  A. Jemal,et al.  Cancer Statistics, 2010 , 2010, CA: a cancer journal for clinicians.

[2]  Matthijs C. Dorst Distinctive Image Features from Scale-Invariant Keypoints , 2011 .

[3]  David Nister,et al.  Bundle Adjustment Rules , 2006 .

[4]  Sangtae Park,et al.  Development of an Automated Steering Mechanism for Bladder Urothelium Surveillance. , 2009, Journal of medical devices.

[5]  Timothy D. Soper,et al.  Scanning fiber endoscopy with highly flexible, 1 mm catheterscopes for wide‐field, full‐color imaging , 2010, Journal of biophotonics.

[6]  Steffen Leonhardt,et al.  A multi-threaded mosaicking algorithm for fast image composition of fluorescence bladder images , 2010, Medical Imaging.

[7]  Gregory D. Hager,et al.  Real-Time Endoscopic Mosaicking , 2006, MICCAI.

[8]  Richard S. Johnston,et al.  A full-color scanning fiber endoscope , 2006, SPIE BiOS.

[9]  Jie Liu,et al.  A Robust Mosaicing Method with Super-Resolution for Optical Medical Images , 2010, MIAR.

[10]  Andrew W. Fitzgibbon,et al.  Bundle Adjustment - A Modern Synthesis , 1999, Workshop on Vision Algorithms.

[11]  Long Quan,et al.  Linear N-Point Camera Pose Determination , 1999, IEEE Trans. Pattern Anal. Mach. Intell..

[12]  Christian Daul,et al.  Mosaicing of Bladder Endoscopic Image Sequences: Distortion Calibration and Registration Algorithm , 2008, IEEE Transactions on Biomedical Engineering.

[13]  Steven M. Seitz,et al.  Photo tourism: exploring photo collections in 3D , 2006, ACM Trans. Graph..

[14]  N. Dubrawsky Cancer statistics , 1989, CA: a cancer journal for clinicians.

[15]  Eric J. Seibel,et al.  Automated Cystoscopic Surveillance System with Endoscopic Image Mosaicing , 2010 .

[16]  Alexander Behrens Creating Panoramic Images for Bladder Fluorescence Endoscopy , 2008 .