Novel Fire Testing Methodology: Why, how and what now?

In response to a need for rational, quantified, and repeatable assessment of building materials subject to heating during fire, a novel fire testing methodology, named the Heat-Transfer Rate Inducing System (H-TRIS), has been developed using an innovative thermal loading technique. H-TRIS is based on the use of a mobile array of propane-fired high performance radiant heating elements, along with a computer-controlled mechanical linear motion system. The thermal loading is actively controlled by incident heat flux measurements at the test element’s exposed surface using a high precision loop feedback system. This paper presents the motivation behind the development of this unique testing methodology, the theoretical and practical procedures behind its conception and operation, and the potential value that H-TRIS may bring to the fire engineering design, research and certification communities.

[1]  G.M.E. Cooke,et al.  Can Harmonisation Of Fire Resistance Furnaces Be Achieved By Plate Thermometer Control , 1994 .

[2]  Peter Schaumann,et al.  MUNICH FIRE TESTS ON MEMBRANE ACTION of Composite Slabs in Fire – Test Results and Recent Findings , 2011 .

[3]  Ulf Wickström,et al.  Calibration of fire resistance test furnaces. , 1989 .

[4]  Vytenis Babrauskas,et al.  Temperature measurement in fire test furnaces , 1978 .

[5]  Ulf Wickström,et al.  The plate thermometer - a simple instrument for reaching harmonized fire resistance tests , 1994 .

[6]  A. Abdel-azim Fundamentals of Heat and Mass Transfer , 2011 .

[7]  Luke Bisby,et al.  Large-scale Structural Fire Testing - How did we get here, Where are we, and Where are we going? , 2012 .

[8]  Mohamed A. Sultan The Effect of Furnace Parameters on Fire Severity in Standard Fire Resistance Tests , 1996 .

[9]  W. A. Hull,et al.  Fire resistance of concrete columns , 2013 .

[10]  Jesse J. Beitel,et al.  Analysis of Needs and Existing Capabilities for Full-Scale Fire Resistance Testing , 2008 .

[11]  P. A. Rubini,et al.  Three-dimensional simulation of a fire-resistance furnace , 1997 .

[12]  U. Wickström A proposal regarding temperature measurements in fire tests furnaces , 1986 .

[13]  Luke Bisby,et al.  Fire Behavior of Thin CFRP Pretensioned High-Strength Concrete Slabs , 2012 .

[14]  T. Z. Harmathy,et al.  The fire resistance test and its relation to real-world fires , 1981 .

[15]  Guillermo Rein,et al.  Structural Engineering and Fire Dynamics: Advances at the Interface and Buchanan's Challenge , 2011 .

[16]  T. Z. Harmathy,et al.  Heat Transmission in Fire Test Furnaces , 1986 .

[17]  Dat Duthinh,et al.  Adiabatic Surface Temperature for Calculating Heat Transfer to Fire Exposed Structures. | NIST , 2007 .

[18]  Cecilia Abecassis Empis Analysis of the compartment fire parameters influencing the heat flux incident on the structural façade , 2010 .

[19]  T Harmathy,et al.  Fire Test Standard in the Light of Fire Research , 1970 .

[20]  Mohamed A. Sultan,et al.  Incident heat flux measurements in floor and wall furnaces of different sizes , 2006 .

[21]  Margaret Law,et al.  Magic numbers and golden rules , 1995 .