Water-core waveguide for pollution measurements in the deep ultraviolet.

A fiber optic system for water analysis with high transparency in the deep-UV region (lambda >/= 190 nm) is presented. The system consists of special UV-improved silica fibers and a liquid-core waveguide (LCW) as an optical cell. The apertures of both light guides, the silica fiber and the LCW, are matched. The optical losses of the device are investigated experimentally and compared with theory, especially with a standard free-space geometry. The performance of the system with respect to UV absorption spectroscopy is demonstrated for nitrate and chlorine pollution in pure water. For a 203-mm-long LCW the detection limits have been determined to be as low as 22 mug/L for nitrate and 26 mug/L for chlorine.

[1]  Karl-Friedrich Klein,et al.  Stability and lifetime improvements of UV fibers for new applications , 1998, Photonics West - Biomedical Optics.

[2]  E. Palik Handbook of Optical Constants of Solids , 1997 .

[3]  H. Franke,et al.  Increasing the accuracy of liquid analysis and pH-value control using a liquid-core waveguide , 1997 .

[4]  H. Georg Schulze,et al.  Fiber-guided tunable UV-laserlight system around 215 nm , 1997, Photonics West - Biomedical Optics.

[5]  Kenneth T. V. Grattan,et al.  Smart-sensor approach for a fibre-optic-based residual chlorine monitor , 1997 .

[6]  Kenneth T. V. Grattan,et al.  Binary encoded 2nd-differential spectrometry using UV-Vis spectral data and neural networks in the estimation of species type and concentration , 1997 .

[7]  Kenneth T. V. Grattan,et al.  UV-stabilized silica-based fibre for applications around 200 nm wavelength , 1997 .

[8]  Kenneth T. V. Grattan,et al.  Water-quality measurement using fiber optics at wavelengths below 230 nm , 1996, Optics & Photonics.

[9]  H. Franke,et al.  A cylindrical liquid-core waveguide , 1996 .

[10]  Peter Karlitschek,et al.  Improved Optical Fibers for Excimer Laser Applications , 1996 .

[11]  Lloyd W. Burgess Absorption-based sensors☆ , 1995 .

[12]  Bo Karlberg,et al.  Determination of nitrate in municipal waste water by UV spectroscopy , 1995 .

[13]  Dermot Diamond,et al.  Comparison of the analytical capabilities of an amperometric and an optical sensor for the determination of nitrate in river and well water , 1994 .

[14]  Robert A. Weeks,et al.  The many varieties of E′ centers: a review , 1994 .

[15]  Kenneth T. V. Grattan,et al.  Design and implementation of a fibre-optic-based residual chlorine monitor , 1993 .

[16]  Jay H. Lowry,et al.  Optical characteristics of Teflon AF fluoroplastic materials , 1992 .

[17]  Wei Wang,et al.  Absorbance study of liquid-core optical fibers in spectrophotometry , 1992 .

[18]  Im Thomas,et al.  A Novel Perfluorinated AR and Protective Coating for KDP and other Optical Materials , 1991 .

[19]  J. B. Simeonsson,et al.  Waveguide capillary flow cell for fluorometry. , 1988, Analytical chemistry.

[20]  R. Kuroda,et al.  Direct simultaneous determination of nitrate and nitrite by ultraviolet second-derivative spectrophotometry , 1987 .

[21]  K. Fuwa,et al.  Source Light Pathways Inside a Long capillary Cell Used for Colorimetry , 1985 .

[22]  P. Dasgupta Multipath cells for extending dynamic range of optical absorbance measurements , 1984 .

[23]  J. Fleming,et al.  Refractive index dispersion and related properties in fluorine doped silica. , 1983, Applied optics.

[24]  K. Fuwa,et al.  Determination of phosphorus in natural waters by long-capillary-cell absorption spectrometry , 1983 .

[25]  M. Munemori,et al.  Continuous flow determination of free chlorine in water , 1983 .

[26]  J. Ingle,et al.  Determination of chlorine in water by luminol chemiluminescence , 1981 .

[27]  G. J. Moody,et al.  Determination of residual chlorine in water with computer automation and residual-chlorine electrode , 1978 .

[28]  J. Stone Optical Transmission in Liquid‐Core Quartz Fibers , 1972 .