Lung perfusion imaging in small animals using 4D micro-CT at heartbeat temporal resolution.

PURPOSE Quantitative in vivo imaging of lung perfusion in rodents can provide critical information for preclinical studies. However, the combined challenges of high temporal and spatial resolution have made routine quantitative perfusion imaging difficult in small animals. The purpose of this work is to demonstrate 4D micro-CT for perfusion imaging in rodents at heartbeat temporal resolution and isotropic spatial resolution. METHODS We have recently developed a dual tube/detector micro-CT scanner that is well suited to capture first pass kinetics of a bolus of contrast agent used to compute perfusion information. Our approach is based on the paradigm that similar time density curves can be reproduced in a number of consecutive, small volume injections of iodinated contrast agent at a series of different angles. This reproducibility is ensured by the high-level integration of the imaging components of our system with a microinjector, a mechanical ventilator, and monitoring applications. Sampling is controlled through a biological pulse sequence implemented in LABVIEW. Image reconstruction is based on a simultaneous algebraic reconstruction technique implemented on a graphic processor unit. The capabilities of 4D micro-CT imaging are demonstrated in studies on lung perfusion in rats. RESULTS We report 4D micro-CT imaging in the rat lung with a heartbeat temporal resolution (approximately 150 ms) and isotropic 3D reconstruction with a voxel size of 88 microm based on sampling using 16 injections of 50 microL each. The total volume of contrast agent injected during the experiments (0.8 mL) was less than 10% of the total blood volume in a rat. This volume was not injected in a single bolus, but in multiple injections separated by at least 2 min interval to allow for clearance and adaptation. We assessed the reproducibility of the time density curves with multiple injections and found that these are very similar. The average time density curves for the first eight and last eight injections are slightly different, i.e., for the last eight injections, both the maximum of the average time density curves and its area under the curve are decreased by 3.8% and 7.2%, respectively, relative to the average time density curves based on the first eight injections. The radiation dose associated with our 4D micro-CT imaging is 0.16 Gy and is therefore in the range of a typical micro-CT dose. CONCLUSIONS 4D micro-CT-based perfusion imaging demonstrated here has immediate application in a wide range of preclinical studies such as tumor perfusion, angiogenesis, and renal function. Although our imaging system is in many ways unique, we believe that our approach based on the multiple injection paradigm can be used with the newly developed flat-panel slip-ring-based micro-CT to increase their temporal resolution in dynamic perfusion studies.

[1]  L. Feldkamp,et al.  Practical cone-beam algorithm , 1984 .

[2]  B. Rosen,et al.  High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part I: Mathematical approach and statistical analysis , 1996, Magnetic resonance in medicine.

[3]  Klaus Mueller,et al.  Rapid 3-D cone-beam reconstruction with the simultaneous algebraic reconstruction technique (SART) using 2-D texture mapping hardware , 2000, IEEE Transactions on Medical Imaging.

[4]  A. Haase,et al.  Can we use vertical bore magnetic resonance scanners for murine cardiovascular phenotype characterization? Influence of upright body position on left ventricular hemodynamics in mice. , 2001, Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance.

[5]  Avinash C. Kak,et al.  Principles of computerized tomographic imaging , 2001, Classics in applied mathematics.

[6]  B. Janssen,et al.  Autonomic control of blood pressure in mice: basic physiology and effects of genetic modification. , 2002, American journal of physiology. Regulatory, integrative and comparative physiology.

[7]  G Allan Johnson,et al.  Mechanical ventilation for imaging the small animal lung. , 2002, ILAR journal.

[8]  S. Morcos Review article: Effects of radiographic contrast media on the lung. , 2003, The British journal of radiology.

[9]  Kieran Clarke,et al.  Fast, high‐resolution in vivo cine magnetic resonance imaging in normal and failing mouse hearts on a vertical 11.7 T system , 2003, Journal of magnetic resonance imaging : JMRI.

[10]  Eric C Frey,et al.  Development of a 4-D digital mouse phantom for molecular imaging research. , 2004, Molecular imaging and biology : MIB : the official publication of the Academy of Molecular Imaging.

[11]  E. Rofstad,et al.  Assessment of tumor blood perfusion by high‐resolution dynamic contrast‐enhanced MRI: A preclinical study of human melanoma xenografts , 2004, Magnetic resonance in medicine.

[12]  G. Allan Johnson,et al.  Optimized radiographic spectra for digital subtraction angiography in the mouse , 2004, 2004 2nd IEEE International Symposium on Biomedical Imaging: Nano to Macro (IEEE Cat No. 04EX821).

[13]  P. Fox,et al.  Non-invasive quantification of cerebral blood flow for rats by microPET imaging of 15O labelled water: the application of a cardiac time–activity curve for the tracer arterial input function , 2005, Nuclear medicine communications.

[14]  D Van Dyck,et al.  In vivo assessment of emphysema in mice by high resolution X‐ray microtomography , 2005, Journal of microscopy.

[15]  André Constantinesco,et al.  Assessment of left ventricular perfusion, volumes, and motion in mice using pinhole gated SPECT. , 2005, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[16]  Wolfhard Semmler,et al.  Potential applications of flat-panel volumetric CT in morphologic and functional small animal imaging. , 2005, Neoplasia.

[17]  David L. Thomas,et al.  Arterial spin labeling in small animals: Methods and applications to experimental cerebral ischemia , 2005, Journal of magnetic resonance imaging : JMRI.

[18]  Ehsan Samei,et al.  Optimized radiographic spectra for small animal digital subtraction angiography. , 2006, Medical physics.

[19]  Ting-Yim Lee,et al.  Image quality assessment of a pre-clinical flat-panel volumetric micro-CT scanner , 2006, SPIE Medical Imaging.

[20]  Kieran Clarke,et al.  CINE-MR imaging of the normal and infarcted rat heart using an 11.7 T vertical bore MR system. , 2006, Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance.

[21]  Jiayu Song,et al.  Sparseness prior based iterative image reconstruction for retrospectively gated cardiac micro-CT. , 2007, Medical physics.

[22]  James Eastwood,et al.  Multidetector Computed Tomography in Cerebrovascular Disease : CT Perfusion Imaging , 2007 .

[23]  Ehsan Samei,et al.  Tomographic digital subtraction angiography for lung perfusion estimation in rodents. , 2007, Medical physics.

[24]  James G. Fox,et al.  The Mouse in biomedical research , 2007 .

[25]  S. Russell,et al.  Small Animal Absorbed Radiation Dose from Serial Micro-Computed Tomography Imaging , 2007, Molecular Imaging and Biology.

[26]  Jens Ricke,et al.  Dynamic perfusion CT: optimizing the temporal resolution for the calculation of perfusion CT parameters in stroke patients. , 2007, European journal of radiology.

[27]  G Allan Johnson,et al.  A MICRO–COMPUTED TOMOGRAPHY–BASED METHOD FOR THE MEASUREMENT OF PULMONARY COMPLIANCE IN HEALTHY AND BLEOMYCIN–EXPOSED MICE , 2007, Experimental lung research.

[28]  G Allan Johnson,et al.  Geometric calibration for a dual tube/detector micro-CT system. , 2008, Medical physics.

[29]  G. Allan Johnson,et al.  A High-Precision Contrast Injector for Small Animal X-Ray Digital Subtraction Angiography , 2008, IEEE Transactions on Biomedical Engineering.

[30]  G. Allan Johnson,et al.  Application of MOSFET Detectors for Dosimetry in Small Animal Radiography Using Short Exposure Times , 2008, Radiation research.

[31]  G Allan Johnson,et al.  Pulmonary perfusion imaging in the rodent lung using dynamic contrast‐enhanced MRI , 2008, Magnetic resonance in medicine.

[32]  Cristian T. Badea,et al.  4D micro-CT-based perfusion imaging in small animals , 2009, Medical Imaging.