Toward Biphasic Computed Tomography (CT) Enteric Contrast: Material Classification of Luminal Bismuth and Mural Iodine in a Small-Bowel Phantom Using Dual-Energy CT

Objective To develop dual-energy computed tomography methods for identification of hyperenhancing, hypoenhancing, and nonenhancing small-bowel pathologies. Methods Small-bowel phantoms simulating varying patient sizes and polyp types (hyperenhancing, hypoenhancing, and nonenhancing) contained bismuth suspension in the lumen. Dual-energy CT was performed at 80/140 kV and 100/140 kV. Computed tomographic number ratios (CT numbers at low/high kilovoltage) were calculated. Two radiologists evaluated polyp detection and conspicuity using bismuth-only, iodine-only, iodine-overlay, and mixed-kilovoltage displays. Results Computed tomographic ratios for bismuth and iodine did not overlap. For hyperenhancing and nonenhancing polyps at 80/140 kV, iodine-overlay display yielded higher detection rate (96%, 94%) and conspicuity score (3.5, 3.1) than mixed-kilovoltage images (88%, 68%; 1.5, 2.7). Mixed-kV images performed slightly better for hypoenhancing polyps (92%, 3.4 vs. <80%, <2.9). Similar results were observed at 100/140kV. Conclusions Dual-energy CT and a bismuth-containing enteric contrast permitted simultaneous identification of hyperenhancing, hypoenhancing, and nonenhancing polyps over a range of patient sizes.

[1]  A. Buge,et al.  Epileptic phenomena in bismuth toxic encephalopathy. , 1981, Journal of neurology, neurosurgery, and psychiatry.

[2]  Shuai Leng,et al.  Dual-energy dual-source CT with additional spectral filtration can improve the differentiation of non-uric acid renal stones: an ex vivo phantom study. , 2011, AJR. American journal of roentgenology.

[3]  Cynthia H McCollough,et al.  Optimal Spectral Filtration for Dual-Energy and Dual-Source CT , 2009 .

[4]  A. Macovski,et al.  Energy-selective reconstructions in X-ray computerised tomography , 1976, Physics in medicine and biology.

[5]  D. Thomas,et al.  Reversible Encephalopathy Possibly Associated with Bismuth Subgallate Ingestion , 1974, British medical journal.

[6]  L F Ward Why is water considered ghost-proof? , 1885, Science.

[7]  Christianne Leidecker,et al.  Dual-energy CT in patients suspected of having renal masses: can virtual nonenhanced images replace true nonenhanced images? , 2009, Radiology.

[8]  Konstantin Nikolaou,et al.  Dual-source CT cardiac imaging: initial experience , 2006, European Radiology.

[9]  James E. Huprich,et al.  CT-Enterography May Identify Small Bowel Tumors Not Detected by Capsule Endoscopy: Eight Years Experience at Mayo Clinic Rochester , 2011, Digestive Diseases and Sciences.

[10]  M. Reiser,et al.  Material differentiation by dual energy CT: initial experience , 2007, European Radiology.

[11]  W. Cannon,et al.  THE MOVEMENTS OF THE FOOD IN THE ŒSOPHAGUS , 1898 .

[12]  D. Bierer,et al.  Bismuth subsalicylate: history, chemistry, and safety. , 1990, Reviews of infectious diseases.

[13]  C. McCollough,et al.  Detectability of urinary stones on virtual nonenhanced images generated at pyelographic-phase dual-energy CT. , 2010, Radiology.

[14]  C. McCollough,et al.  Improved dual-energy material discrimination for dual-source CT by means of additional spectral filtration. , 2009, Medical physics.

[15]  James C. Williams,et al.  Noninvasive differentiation of uric acid versus non-uric acid kidney stones using dual-energy CT. , 2007, Academic radiology.

[16]  C. McCollough,et al.  Prospective blinded comparison of wireless capsule endoscopy and multiphase CT enterography in obscure gastrointestinal bleeding. , 2011, Radiology.

[17]  W. Cannon The Movements Of The Stomach Studied By Means Of The Röntgen Rays... , 1898 .

[18]  J. Fletcher,et al.  Computerized tomography enterography and its role in small-bowel imaging. , 2008, Clinical gastroenterology and hepatology : the official clinical practice journal of the American Gastroenterological Association.