Detection of Phosphate in Human Blood Based on a Catalytic Hydrogen Wave at a Molybdenum Phosphide Modified Electrode.

Detection of inorganic phosphate is very important in environmental and health care applications. In this work, we found that phenomenon similar to "catalytic hydrogen wave" occurred on a molybdenum phosphide (MoP) modified electrode in the presence of phosphate, that is, a new wave of catalytic hydrogen evolution appeared before the normal hydrogen evolution reaction. The catalytic hydrogen wave arose from a structure similar to phosphomolybdic acid (noted as MoPO), which was formed by the interaction between phosphate and molybdenum oxides on the surface of the MoP modified electrode, resulting in the altered surface structure and adjusted interface catalytic activity. A novel phosphate electrochemical sensor was constructed based on this phenomenon with a linear range from 0.10 to 20.0 mmol·L-1, an actually determined minimum concentration of 0.030 mmol·L-1, and recoveries of 94%-107%, and this sensor was successfully applied to the detection of phosphate in human blood. Furthermore, this work proposes a new sensing method based on catalytic hydrogen waves on the modified electrodes.

[1]  H. D. Duong,et al.  Ratiometric fluorescence sensors for the detection of HPO42− and H2PO4− using different responses of the morin-hydrotalcite complex , 2018, Sensors and Actuators B: Chemical.

[2]  O. Shirai,et al.  Phosphate ion sensor using a cobalt phosphate coated cobalt electrode , 2018, Electrochimica Acta.

[3]  Yuhui Wang,et al.  Applying Carbon Dots-Metal Ions Ensembles as a Multichannel Fluorescent Sensor Array: Detection and Discrimination of Phosphate Anions. , 2017, Analytical chemistry.

[4]  A. Campiglia,et al.  Selective nano-sensing approach for the determination of inorganic phosphate in human urine samples. , 2017, Talanta.

[5]  Xiaodong Yu,et al.  Phosphate Sensor Using Molybdenum , 2016 .

[6]  G. Palleschi,et al.  Screen-printed electrode modified with carbon black nanoparticles for phosphate detection by measuring the electroactive phosphomolybdate complex. , 2015, Talanta.

[7]  Danila Moscone,et al.  Phosphate Detection through a Cost-Effective Carbon Black Nanoparticle-Modified Screen-Printed Electrode Embedded in a Continuous Flow System. , 2015, Environmental science & technology.

[8]  R. Kubinec,et al.  Gas chromatography with mass spectrometry analysis of phosphoserine, phosphoethanolamine, phosphoglycerol, and phosphate. , 2015, Journal of separation science.

[9]  N. Stradiotto,et al.  Potentiometric determination of phosphorus in biodiesel using chemically modified electrode with cobalt film , 2014 .

[10]  Fenglin Yang,et al.  pH-dependent structure and photochromic properties of phosphomolybdic acid/polyacrylamide composite films , 2013 .

[11]  S. Adeloju,et al.  Progress and recent advances in phosphate sensors: a review. , 2013, Talanta.

[12]  Sheela Berchmans,et al.  Determination of inorganic phosphate by electroanalytical methods: a review. , 2012, Analytica chimica acta.

[13]  Wuzong Zhou,et al.  Controllable selective exfoliation of high-quality graphene nanosheets and nanodots by ionic liquid assisted grinding. , 2012, Chemical communications.

[14]  Ildikó V. Tóth,et al.  Development of a flow method for the determination of phosphate in estuarine and freshwaters--comparison of flow cells in spectrophotometric sequential injection analysis. , 2011, Analytica chimica acta.

[15]  K. Pitchumani,et al.  Per-6-ammonium-β-cyclodextrin/p-nitrophenol complex as a colorimetric sensor for phosphate and pyrophosphate anions in water , 2011 .

[16]  Neda Masoudipour,et al.  Application of a new potentiometric method for determination of phosphate based on a surfactant-modified zeolite carbon-paste electrode (SMZ-CPE). , 2010, Analytica chimica acta.

[17]  P. Weiss,et al.  The emergence of phosphate as a specific signaling molecule in bone and other cell types in mammals , 2010, Cellular and Molecular Life Sciences.

[18]  S. Pourbeyram,et al.  Zirconium immobilized on gold-mercaptopropionic acid self-assembled monolayer for trace determination of phosphate in blood serum by using CV, EIS, and OSWV. , 2009, Biosensors & bioelectronics.

[19]  H. Tian,et al.  A colorimetric and fluorescent turn-on sensor for pyrophosphate anion based on a dicyanomethylene-4H-chromene framework. , 2008, Chemical communications.

[20]  C. McKenna,et al.  Metal complexation chemistry used for phosphate and nucleotide determination: an investigation of the Yb3+–pyrocatechol violet sensor , 2008, JBIC Journal of Biological Inorganic Chemistry.

[21]  O. Reynes,et al.  Electrochemical sensing of dihydrogen phosphate and adenosine-5′-triphosphate anions by self-assembled monolayers of (ferrocenylmethyl)trialkylammonium cations on gold electrodes , 2008 .

[22]  Jae Sang Kim,et al.  Functional polyterthiophene-appended uranyl-salophen complex: electropolymerization and ion-selective response for monohydrogen phosphate. , 2008, Analytica chimica acta.

[23]  Manuel A. Palacios,et al.  Rational design of a fluorescence-turn-on sensor array for phosphates in blood serum. , 2007, Angewandte Chemie.

[24]  B. K. Mohapatra,et al.  Synthesis, characterization, and catalytic activity of phosphomolybdic acid supported on hydrous zirconia. , 2006, Journal of colloid and interface science.

[25]  Seung-Cheol Chang,et al.  The biosensor based on the pyruvate oxidase modified conducting polymer for phosphate ions determinations. , 2006, Biosensors & bioelectronics.

[26]  T. Reemtsma,et al.  Determination of phosphoric acid mono- and diesters in municipal wastewater by solid-phase extraction and ion-pair liquid chromatography-tandem mass spectrometry. , 2006, Analytical chemistry.

[27]  Maotian Xu,et al.  Polarographic Behavior of Gemfibrozil in the Presence of Dissolved Oxygen and Its Analytical Application , 2004 .

[28]  Wei Guo,et al.  Study and application of parallel catalytic hydrogen wave of lincomycin in the presence of persulfate , 2004 .

[29]  B. Wehrli,et al.  Nutrient transfer from soil to surface waters: Differences between nitrate and phosphate , 2004, Aquatic Sciences.

[30]  Maotian Xu,et al.  Rapid determination of telmisartan in pharmaceuticals and serum by the parallel catalytic hydrogen wave method , 2003, Analytical and bioanalytical chemistry.

[31]  E. Anslyn,et al.  Determination of inorganic phosphate in serum and saliva using a synthetic receptor. , 2003, Organic letters.

[32]  J. Chi,et al.  Automated analysis of nanomolar concentrations of phosphate in natural waters with liquid waveguide. , 2002, Environmental science & technology.

[33]  C. Stamm,et al.  Transport of phosphate from soil to surface waters by preferential flow , 1998 .

[34]  J. Cox,et al.  Determination of phosphate by cathodic stripping chronopotentiometry at a copper electrode , 1974 .

[35]  M. Fleischmann,et al.  Electrocrystallization of ruthenium and electrocatalysis of hydrogen evolution , 1972 .

[36]  H. Thirsk,et al.  Kinetics of electrodeposition and catalytic activity of thin films of ruthenium , 1967 .

[37]  W. Holman A new technique for the determination of phosphorus by the molybdenum blue method. , 1943, The Biochemical journal.

[38]  I. Berenblum,et al.  Studies on the colorimetric determination of phosphate. , 1938, The Biochemical journal.

[39]  C. H. Fiske,et al.  THE COLORIMETRIC DETERMINATION OF PHOSPHORUS , 1925 .