Calibrator Design for the COBE Far Infrared Absolute Spectrophotometer (FIRAS)

The photometric errors of the external calibrator for the Far Infrared Absolute Spectrophotometer (FIRAS) instrument on the COBE are smaller than the measurement errors on the cosmic microwave background radiation (CMBR) spectrum (typically 0.02 MJy sr-1, 1 σ) and smaller than 0.01% of the peak brightness of the CMB. The calibrator is a reentrant cone, shaped like a trumpet mute, made of Eccosorb iron-loaded epoxy. It fills the entire beam of the instrument and is the source of its accuracy. Its known errors are caused by reflections, temperature gradients, and leakage through the material and around the edge. Estimates and limits are given for all known error sources. Improvements in understanding the temperature measurements of the calibrator allow an improved CMB temperature determination of 2.725±0.002 K.

[1]  C. Bennett,et al.  The Spectrum of the Extragalactic Far-Infrared Background from the COBE FIRAS Observations , 1998, astro-ph/9803021.

[2]  D. Fixsen The Spectrum of the Cosmic Microwave Background Anisotropy from the Combined COBE FIRAS and WMAP Observations , 1997, astro-ph/9704176.

[3]  E. L. Wright,et al.  The Cosmic Microwave Background Spectrum from the Full COBE FIRAS Data Set , 1996, astro-ph/9605054.

[4]  K. Gorski,et al.  Cosmic temperature fluctuations from two years of COBE differential microwave radiometers observations , 1994 .

[5]  Dale J. Fixsen,et al.  Calibration of the COBE FIRAS instrument , 1994 .

[6]  C. Bennett,et al.  INTERPRETATION OF THE COBE FIRAS CMBR SPECTRUM , 1994 .

[7]  C. Bennett,et al.  Measurement of the Cosmic Microwave Background spectrum by the COBE FIRAS instrument , 1994 .

[8]  Dale J. Fixsen,et al.  Design for the COBE far-infrared absolute spectrophotometer , 1993, Optics & Photonics.

[9]  C. Bennett,et al.  The COBE Mission: Its Design and Performance Two Years after Launch , 1992 .

[10]  G. Hinshaw,et al.  COBE differential microwave radiometers - Calibration techniques , 1992 .

[11]  M. Halpern,et al.  Far infrared transmission of dielectrics at cryogenic and room temperatures: glass, Fluorogold, Eccosorb, Stycast, and various plastics. , 1986, Applied optics.

[12]  P. Richards,et al.  A cryogenic blackbody for millimeter wavelengths , 1984 .

[13]  J. Mather,et al.  Sky input horn for a far-infrared interferometer. , 1982, Optics letters.

[14]  J. Mather Broad-band flared horn with low sidelobes , 1981 .

[15]  John C. Mather The Cosmic Background Explorer (COBE) , 1981, Other Conferences.

[16]  G. Cuming Thmuis Revisited: Another Look at the Prayers of Bishop Sarapion , 1980 .

[17]  D. H. Martin,et al.  Polarised interferometric spectrometry for the millimetre and submillimetre spectrum , 1970 .

[18]  Y. Zeldovich,et al.  The interaction of matter and radiation in a hot-model universe , 1969 .