A Commentary on Partial Discharge Measurement and Detection

A critical review is presented on the various electrical methods available for partial discharge detection and measurement in terms of their chronological development and application on cable, capacitor, transformer, and machine insulation specimens. A substantial portion of the effort is devoted to corona pulse detection techniques, because these constitute the most popular forms of corona measurement. It is pointed out, however, that under some conditions discharges may assume a pulseless or pseudo-glow type character and that in such circumstances pulse detection procedures become ineffective and must be replaced by appropriate bridge methods.

[1]  R. Bartnikas,et al.  Use of a Multichannel Analyzer for Corona Pulse-Height Distribution Measurements on Cables and Other Electrical Apparatus , 1973 .

[2]  G. S. Eager,et al.  Discharge Detection in Extruded Polyethylene Insulated Power Cables , 1967 .

[3]  R. Bartnikas Corona pulse probability density function measurements on primary distribution power cables , 1975, IEEE Transactions on Power Apparatus and Systems.

[4]  R. E. James,et al.  Interpretation of Partial Discharge Quantities as Measured at the Terminals of HV Power Transformers , 1986, IEEE Transactions on Electrical Insulation.

[5]  R. Bartnikas,et al.  A Study of Corona Discharge Rate and Energy Loss in Spark Gaps , 1965 .

[6]  R. Bartnikas,et al.  A Simple Pulse-Height Analyzer for Partial-Discharge-Rate Measurements , 1969 .

[7]  A.E.W. Austen,et al.  Internal discharges in dielectrics: their observation and analysis , 1944 .

[8]  G. E. Quinn,et al.  A method for detecting the ionization point on electrical apparatus , 1940, Electrical Engineering.

[9]  A. M. Sletten,et al.  Corona Location in Transformers by Radio Frequency Spectrum Analysis, Part I: Theory , 1970 .

[10]  Nelson K. Y. Leung,et al.  The application of the pulse discrimination system to the measurement of partial discharges in insulation under noisy conditions , 1980, 1980 IEEE International Conference on Electrical Insulation.

[11]  R. Bartnikas,et al.  Cable specimen length effects on the response of corona pulse detectors , 1976, 1976 IEEE International Conference on Electrical Insulation.

[12]  F. H. Gooding,et al.  Corona-Level Scanning or High-Voltage Power Cables , 1957, Transactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems.

[13]  A. T. Starr,et al.  The measurement of discharges in dielectrics , 1936 .

[14]  R. Bartnikas,et al.  Note on ac Discharges between Metallic‐Dielectric Electrodes in Helium , 1969 .

[15]  T. W. Dakin,et al.  A Capacitance Bridge Method for Measuring Integrated Corona-Charge Transfer and Power Loss per Cycle , 1960, Transactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems.

[16]  J. H. Mason The deterioration and breakdown of dielectrics resulting from internal discharges , 1951 .

[17]  R. J. Hopkins,et al.  Development of Corona Measurements and Their Relation to the Dielectric Strength of Capacitors , 1951, Transactions of the American Institute of Electrical Engineers.

[18]  R. T. Harrold Voltage Vector Analysis for Corona Location in Transformers , 1971 .

[19]  G. C. Stone,et al.  Partial discharge testing of generator insulation , 1978, 1978 IEEE International Conference on Electrical Insulation.

[20]  Paul Narbut Transformer Corona Measurement Using Condenser Bushing Tap and Resonant Measuring Circuits , 1965 .

[21]  Robert B. Blodgett,et al.  Cable Corona Signals - Their Origin and Detection , 1968 .

[22]  G. Stone,et al.  Fundamental Limitations in the Measurement of Corona and Partial Discharge , 1982, IEEE Transactions on Electrical Insulation.

[23]  F. H. Gooding,et al.  Corona-level scanning of high-voltage power cables , 1958, Electrical Engineering.

[24]  S. Reynolds Test Methods for Measuring Energy in a Gas Discharge , 1957 .

[25]  R. Bartnikas,et al.  Some Observations on the Character of Corona Discharges in Short Gap Spaces , 1971, IEEE Transactions on Electrical Insulation.

[26]  Ryszard Malewski,et al.  Comparison of Three Techniques of Partial Discharge Measurements in Power Transformers , 1985, IEEE Transactions on Power Apparatus and Systems.

[27]  G.G. MacFarlane On the Energy-Spectrum of an Almost Periodic Succession of Pulses , 1949, Proceedings of the IRE.

[28]  Vladimir Karapetoff Corona Ellipses , 1929, Transactions of the American Institute of Electrical Engineers.

[29]  R. D. Brown Corona Measurement on High-Voltage Apparatus Using the Bushing Capacitance Tap , 1965 .

[30]  J. S. Johnson,et al.  A Maintenance Inspection Program for Large Rotating Machines , 1951, Transactions of the American Institute of Electrical Engineers.

[31]  D. A. Findlay,et al.  Evaluation of the Internal Insulation of Generator Coils Based on Power-Factor Measurements , 1959, Transactions of the American Institute of Electrical Engineers Part III Power Apparatus and Systems.

[32]  G. S. Eager,et al.  Corona Detection Experience in Commercial Production of Power Cables with Extruded Insulation , 1969 .

[33]  F. J. Vogel,et al.  Corona Measurements and Their Interpretation Applied to Oil Insulated Transformers , 1972 .

[34]  G. Stone,et al.  In-Service Partial Discharge Testing of Generator Insulation , 1979, IEEE Transactions on Electrical Insulation.

[35]  K. Feser,et al.  A New Method for Detection and Location of Distributed Partial Discharges (Cable Faults) in High Voltage Cables Under External Interference , 1982, IEEE Transactions on Power Apparatus and Systems.

[36]  E. B. Paine,et al.  Corona discharge on rubber-insulated cables , 1940, Electrical Engineering.

[37]  John Austin,et al.  On-Line Digital Computer System for Measurementof Partial Discharges in Insulation Structures , 1976, IEEE Transactions on Electrical Insulation.

[38]  M. Kurtz,et al.  Generator Insulation Diagnostic Testing , 1979, IEEE Transactions on Power Apparatus and Systems.

[39]  R. Bartnikas Effect of Pulse Rise Time on the Response of Corona Detectors , 1972, IEEE Transactions on Electrical Insulation.

[40]  Thomas W. Dakin,et al.  The Relationship Between the Picocoolomb and Microvolt for Corona Measurements on HV Transformers and Other Apparatus , 1973 .

[41]  R. Bartnikas,et al.  Discharge rate and energy loss in helium at low frequencies , 1969 .

[42]  J. S. Johnson,et al.  An Electromagnetic Probe for Detecting and Locating Discharges in Large Rotating-Machine Stators , 1969 .

[43]  J. P. Vora,et al.  Power Transformers and Corona Testing , 1965 .

[44]  R. C. Madge,et al.  Coupling Devices for the Detection of Partial Discharges in Gas-Insulated Switchgear , 1981 .

[45]  Graham Williams,et al.  Conference on Electrical Insulation and Dielectric Phenomena , 1982, IEEE Transactions on Electrical Insulation.

[46]  Toshikatsu Tanaka,et al.  A minicomputer-based partial discharge measurement system , 1978, 1978 IEEE International Conference on Electrical Insulation.

[47]  T. C. Manley The Electric Characteristics of the Ozonator Discharge , 1943 .

[48]  R. Bartnikas,et al.  Corona Pulse Charge Transfer at Elevated Frequencies , 1983, IEEE Transactions on Electrical Insulation.

[49]  R. Bartnikas,et al.  Improved Pulsed Discharge Rate Measuring Apparatus for Ionization Discharge Studies at Low Frequencies , 1966 .

[50]  W. L. Lloyd,et al.  Methods Used in Investigating Corona Loss By Means of the Cathode Ray Oscillograph , 1927, Transactions of the American Institute of Electrical Engineers.

[51]  H. A. Cole A differential pulse-height discriminator with full channel logic using two integrated circuits , 1976 .

[52]  R Bartnikas,et al.  Note on discharges in helium under a.c. conditions , 1968 .

[53]  C. L. Dawes,et al.  Ionization studies in paper-insulated cables — I , 1926, Journal of the A.I.E.E..

[54]  J. S. Johnson,et al.  Detection of Slot Discharges in High-Voltage Stator Windings During Operation , 1951, Transactions of the American Institute of Electrical Engineers.

[55]  Frederick E. Wherry,et al.  The Significance of Corona Measurements on Transformers , 1968 .

[56]  J. Nye Corona Detection and Measurement at Sixty Cycles , 1957 .

[57]  W. Weeks,et al.  Instrumentation for the Detection and Locatiion of Incipient Faults on Power Cables , 1982, IEEE Transactions on Power Apparatus and Systems.

[58]  A. Wilson,et al.  Discharge detection under noisy conditions , 1974 .

[59]  R. T. Harrold Corona Location in Transformers by Radio Frequency Spectrum Analysis II. Application of Technique and Results of Measurements , 1970 .

[60]  S. Whitehead,et al.  Discharges in insulation under alternating-current stresses , 1941 .