In vitro biocompatibility of a polyurethane catheter after deposition of fluorinated film.

The in vitro biocompatibility of an experimental surface-treated polyurethane was compared with an untreated polyurethane already used for intravascular catheters. The experimental surface was coated with a fluorinated film using a glow discharge treatment. Neither of the catheters was cytotoxic for L929 murine fibroblasts, caused platelet adhesion or release reaction, or changed the mean platelet volume. The surface-treated polyurethane, however, caused a higher adhesion of Staphylococcus aureus than did the untreated one. Therefore, using in vitro testing, it has been ascertained that the examined material, though not being cytotoxic and not modifying platelet behaviour, could favour bacterial adherence.

[1]  C. N. Reilley,et al.  ESCA study of polymer surfaces treated by plasma , 1977 .

[2]  D. W. Rice,et al.  Preparation and Characterization of Glow Discharge Fluorocarbon-Type Polymers , 1976 .

[3]  M. Rosdy,et al.  Cytotoxicity testing of wound dressings using normal human keratinocytes in culture. , 1990, Journal of biomedical materials research.

[4]  A Pizzoferrato,et al.  Cell culture methods for testing biocompatibility. , 1994, Clinical materials.

[5]  H. Yasuda,et al.  Lindholm blood coagulation test values of some glow-discharge polymer surfaces. , 1976, Biomaterials, medical devices, and artificial organs.

[6]  G. Ciapetti,et al.  Comparative study of the thromboresistance of Dacron combined with various polyurethanes. , 1989, Biomaterials.

[7]  Alexis T. Bell,et al.  Plasma polymerization of tetrafluoroethylene , 1979 .

[8]  A. Hoffman Ionizing Radiation and Gas Plasma (or Glow) Discharge Treatments for Preparation of Novel Polymeric Biomaterials , 1984 .

[9]  L. Fleisher,et al.  Effect of heparin bonding on catheter-induced fibrin formation and platelet activation. , 1984, Circulation.

[10]  J. Feijen,et al.  An in vitro study of the adhesion of blood platelets onto vascular catheters. Part I. , 1987, Journal of biomedical materials research.

[11]  D. Pepper,et al.  The release of a human platelet specific protein measured by a radioimmunoassay. , 1975, Thrombosis research.

[12]  G. Peters,et al.  Adherence and growth of coagulase-negative staphylococci on surfaces of intravenous catheters. , 1982, The Journal of infectious diseases.

[13]  A. Hoffman,et al.  The Small Diameter Vascular Graft - A Challenging Biomaterials Problem , 1985 .

[14]  J. Feijen,et al.  Covalently bound conjugates of albumin and heparin: synthesis, fractionation and characterization. , 1983, Thrombosis research.

[15]  E. Pişkin,et al.  Proteins and Cells on Polyurethane Surfaces , 1992 .

[16]  A. Hoffman,et al.  Effects of a tetrafluoroethylene glow discharge on patency of small diameter dacron vascular grafts. , 1984, Transactions - American Society for Artificial Internal Organs.

[17]  C. N. Reilley,et al.  Some aspects of plasma polymerization of fluorine‐containing organic compounds. II. Comparison of ethylene and tetrafluoroethylene , 1978 .

[18]  H. Isenberg,et al.  Microbiology of indwelling central intravascular catheters , 1988, Journal of clinical microbiology.

[19]  L. Rubin,et al.  Intravenous catheter-related infections. , 1995, Advances in pediatric infectious diseases.

[20]  J. Barbenel,et al.  Interaction of Blood, Blood Components and Surfaces , 1986 .