Computer-assisted navigation in total knee arthroplasty: a review of literature

Abstract Computer-assisted navigation surgery (CAS) has been performed in total knee arthroplasty (TKA) for approximately 10 years. This technique offers experienced and inexperienced surgeons improved control and reproducible results. Currently, 30% of primary total knee replacements are performed using the CAS technique in Germany. The main problems after total knee replacement are generally aseptic loosening, instability and infection. According to various authors, the main reason for aseptic loosening is an inadequate alignment of the mechanical limb axis. Several level I and II studies have demonstrated that CAS leads to significantly less axial deviation. Nevertheless, there are critical arguments against CAS for routine use, such as longer operation times and higher costs. Additionally, there are still no long-term results available that post a definitive statement about lower revision rates, declining numbers of aseptic loosening, cost-effectiveness and clinical outcomes following CAS.

[1]  Chih-Wei Chang,et al.  Blood Loss After Minimally Invasive Total Knee Arthroplasty: Effects of Imageless Navigation , 2010, The Kaohsiung journal of medical sciences.

[2]  H. Chong,et al.  Computer-assisted gap balancing technique improves outcome in total knee arthroplasty, compared with conventional measured resection technique , 2011, Knee Surgery, Sports Traumatology, Arthroscopy.

[3]  D. Dennis,et al.  Mini-incision Total Knee Arthroplasty Can Increase Risk of Component Malalignment , 2005, Clinical orthopaedics and related research.

[4]  P. Sharkey,et al.  Insall Award paper. Why are total knee arthroplasties failing today? , 2002, Clinical orthopaedics and related research.

[5]  S. M. Ong,et al.  Can knee position save blood following total knee replacement? , 2003, The Knee.

[6]  L. Lidgren,et al.  Past incidence and future demand for knee arthroplasty in Sweden: A report from the Swedish Knee Arthroplasty Register regarding the effect of past and future population changes on the number of arthroplasties performed , 2000, Acta orthopaedica Scandinavica.

[7]  J Lützner,et al.  [Cost analysis for navigation in knee endoprosthetics]. , 2009, Der Orthopade.

[8]  C. Cook,et al.  Postoperative morbidity and mortality following total knee arthroplasty with computer navigation. , 2010, The Knee.

[9]  M. Tingart,et al.  [Advances in soft tissue management in total knee arthroplasty. The use of imageless navigation systems]. , 2006, Der Orthopade.

[10]  J P Cobb,et al.  Computer navigation versus conventional total knee replacement. , 2007, The Journal of bone and joint surgery. British volume.

[11]  J. J. Jacobs,et al.  Malrotation Causing Patellofemoral Complications After Total Knee Arthroplasty , 1998, Clinical orthopaedics and related research.

[12]  M. Ritter,et al.  Postoperative alignment of total knee replacement. Its effect on survival. , 1994, Clinical orthopaedics and related research.

[13]  K. Saleh,et al.  Soft‐tissue Balancing During Total Knee Arthroplasty in the Varus Knee , 2009, The Journal of the American Academy of Orthopaedic Surgeons.

[14]  M. Ritter,et al.  Tibial Component Failure Mechanisms in Total Knee Arthroplasty , 2004, Clinical orthopaedics and related research.

[15]  Aree Tanavalee,et al.  A comparison of blood loss in minimally invasive surgery with and without electromagnetic computer navigation in total knee arthroplasty. , 2009, Journal of the Medical Association of Thailand = Chotmaihet thangphaet.

[16]  H. Chong,et al.  Computer-assisted minimally invasive total knee arthroplasty compared with standard total knee arthroplasty. A prospective, randomized study. , 2008, The Journal of bone and joint surgery. American volume.

[17]  Chun‐Hsiung Huang,et al.  Long-term results of total condylar knee arthroplasty. , 2005, The Journal of arthroplasty.

[18]  J Emmerich,et al.  [Navigator concept. Optimizing the procedure for navigated total knee arthroplasty]. , 2005, Der Orthopade.

[19]  M. Kester,et al.  Minimally invasive total knee arthroplasty. , 2004, The Journal of bone and joint surgery. American volume.

[20]  A. Ferretti,et al.  Tibial stress fracture after computer-navigated total knee arthroplasty , 2010, Journal of Orthopaedics and Traumatology.

[21]  T. Fehring,et al.  Knee instability after total knee arthroplasty. , 1994, Clinical orthopaedics and related research.

[22]  Gerard A Engh,et al.  The difficult knee: severe varus and valgus. , 2003, Clinical orthopaedics and related research.

[23]  Steven M. Kurtz,et al.  The Epidemiology of Revision Total Knee Arthroplasty in the United States , 2009 .

[25]  A. J. Floyd,et al.  Robotic systems in orthopaedic surgery. , 2011, The Journal of bone and joint surgery. British volume.

[26]  J. Rand,et al.  Ten-year evaluation of geometric total knee arthroplasty. , 1988, Clinical orthopaedics and related research.

[27]  M. Pfeiffer,et al.  Navigation of total knee arthroplasty: rotation of components and clinical results in a prospectively randomized study , 2011, BMC musculoskeletal disorders.

[28]  B. Morrey Navigated Total Knee Replacement: A Meta-Analysis , 2008 .

[29]  Frederick W Werner,et al.  The effect of valgus/varus malalignment on load distribution in total knee replacements. , 2005, Journal of biomechanics.

[30]  W. Mihalko,et al.  Comparison of Ligament-Balancing Techniques During Total Knee Arthroplasty , 2003, The Journal of bone and joint surgery. American volume.

[31]  K. Bozic,et al.  The cost-effectiveness of computer-assisted navigation in total knee arthroplasty. , 2007, The Journal of bone and joint surgery. American volume.

[32]  Y Kalairajah,et al.  Are systemic emboli reduced in computer-assisted knee surgery?: A prospective, randomised, clinical trial. , 2006, The Journal of bone and joint surgery. British volume.

[33]  J D Reuben,et al.  The effect of femoral component position on patellar tracking after total knee arthroplasty. , 1990, Clinical orthopaedics and related research.

[34]  A. Edidin,et al.  Transesophageal Echocardiographic Monitored Events During Total Knee Arthroplasty , 1996, Clinical orthopaedics and related research.

[35]  M. Kuster,et al.  Clinical outcome using a ligament referencing technique in CAS versus conventional technique , 2010, Knee Surgery, Sports Traumatology, Arthroscopy.

[36]  Yogeesh D. Kamat,et al.  Does computer navigation in total knee arthroplasty improve patient outcome at midterm follow-up? , 2009, International Orthopaedics.

[37]  M. Tingart,et al.  A five to seven year follow-up comparing computer-assisted vs freehand TKR with regard to clinical parameters , 2012, International Orthopaedics.

[38]  Nicola Biasca,et al.  Mechanical accuracy of navigated minimally invasive total knee arthroplasty (MIS TKA). , 2009, The Knee.

[39]  Markus Tingart,et al.  Computer-assisted total knee arthroplasty versus the conventional technique: how precise is navigation in clinical routine? , 2007, Knee Surgery, Sports Traumatology, Arthroscopy.

[40]  Steven Kurtz,et al.  Prevalence of primary and revision total hip and knee arthroplasty in the United States from 1990 through 2002. , 2005, The Journal of bone and joint surgery. American volume.

[41]  Martin Buxton,et al.  Early assessment of the likely cost-effectiveness of a new technology: A Markov model with probabilistic sensitivity analysis of computer-assisted total knee replacement , 2006, International Journal of Technology Assessment in Health Care.

[42]  O. Mahoney,et al.  The effect of total knee arthroplasty design on extensor mechanism function. , 2002, The Journal of arthroplasty.

[43]  R Nizard,et al.  Computer assisted surgery for total knee arthroplasty. , 2002, Acta orthopaedica Belgica.

[44]  C. Valle,et al.  Instability in primary total knee arthroplasty. , 2011 .

[45]  M. Tingart,et al.  The effect of femoral component rotation on patellar tracking in total knee arthroplasty. , 2007, Orthopedics.

[46]  C. Leelasestaporn Comparative mechanical axis deviation after TKA between conventional and CAS procedure. , 2010, Journal of the Medical Association of Thailand = Chotmaihet thangphaet.

[47]  I. Pinder,et al.  Quality of life after knee revision arthroplasty , 2006, Acta orthopaedica.

[48]  M. Tingart,et al.  Minimal invasive and computer assisted total knee replacement compared with the conventional technique: a prospective, randomised trial , 2008, Knee Surgery, Sports Traumatology, Arthroscopy.

[49]  M Tingart,et al.  [Navigated implantation of total knee endoprostheses in secondary knee osteoarthritis of rheumatoid arthritis patients as compared to conventional technique]. , 2004, Zeitschrift fur Rheumatologie.

[50]  Alexander Giurea,et al.  Learning curve in navigated total knee replacement. A multi-centre study comparing experienced and beginner centres. , 2008, The Knee.

[51]  J. Grifka,et al.  CT-basierte und CT-freie Navigation in der Knieendoprothetik , 2003, Der Unfallchirurg.

[52]  S. J. Park,et al.  Comparison of functional results with navigation-assisted minimally invasive and conventional techniques in bilateral total knee arthroplasty , 2007, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[53]  J Grifka,et al.  [Are computer assisted total knee replacements more accurately placed? A meta-analysis of comparative studies]. , 2006, Der Orthopade.

[54]  T. Cheng,et al.  Imageless navigation system does not improve component rotational alignment in total knee arthroplasty. , 2011, The Journal of surgical research.

[55]  D. Hernández-Vaquero,et al.  Navigation in total knee arthroplasty. A multicenter study , 2006, International Orthopaedics.

[56]  D. König,et al.  The effect of computer navigation on blood loss and transfusion rate in TKA. , 2010, Orthopedics.

[57]  W. Breidahl,et al.  Computer-assisted knee arthroplasty versus a conventional jig-based technique. A randomised, prospective trial. , 2004, The Journal of bone and joint surgery. British volume.

[58]  K A Krackow,et al.  A new technique for determining proper mechanical axis alignment during total knee arthroplasty: progress toward computer-assisted TKA. , 1999, Orthopedics.

[59]  G. Engh,et al.  Radiographic assessment of knee alignment after total knee arthroplasty. , 1988, The Journal of arthroplasty.

[60]  F. Picard,et al.  Blood loss following total knee replacement in the morbidly obese: Effects of computer navigation. , 2011, The Knee.

[61]  P. Nicolai,et al.  The effect of surgeon experience on component positioning in 673 Press Fit Condylar posterior cruciate-sacrificing total knee arthroplasties. , 2001, The Journal of arthroplasty.

[62]  J. Aström,et al.  Alignment and long-term clinical results of a semiconstrained knee prosthesis. , 1988, Clinical orthopaedics and related research.

[63]  Tao Cheng,et al.  Does computer-assisted surgery improve postoperative leg alignment and implant positioning following total knee arthroplasty? A meta-analysis of randomized controlled trials? , 2012, Knee Surgery, Sports Traumatology, Arthroscopy.

[64]  Lawrence Joseph,et al.  Imageless computer assisted versus conventional total knee replacement. A Bayesian meta-analysis of 23 comparative studies , 2011, International Orthopaedics.

[65]  M. Tingart,et al.  Two year follow-up comparing computer assisted versus freehand TKR on joint stability, muscular function and patients satisfaction , 2009, Knee Surgery, Sports Traumatology, Arthroscopy.

[66]  Q. Fu,et al.  Alignment outcomes in navigated total knee arthroplasty: a meta-analysis , 2012, Knee Surgery, Sports Traumatology, Arthroscopy.

[67]  Mark H. Gonzalez,et al.  The Failed Total Knee Arthroplasty: Evaluation and Etiology , 2004, The Journal of the American Academy of Orthopaedic Surgeons.

[68]  C. Bombardier,et al.  Health-related quality of life after knee replacement. , 1998, The Journal of bone and joint surgery. American volume.

[69]  M. Kurosaka,et al.  Mid-term outcomes of computer-assisted total knee arthroplasty , 2011, Knee Surgery, Sports Traumatology, Arthroscopy.

[70]  P. Boisrenoult,et al.  Pin track induced fractures around computer-assisted TKA. , 2010, Orthopaedics & traumatology, surgery & research : OTSR.

[71]  G. Scuderi**,et al.  Survivorship of cemented total knee arthroplasty. , 1997, Clinical orthopaedics and related research.

[72]  J. Argenson,et al.  [Minimally invasive total knee arthroplasty]. , 2005, Revue de chirurgie orthopedique et reparatrice de l'appareil moteur.

[73]  Michael Nogler,et al.  Navigation Improves Accuracy of Rotational Alignment in Total Knee Arthroplasty , 2004, Clinical orthopaedics and related research.

[74]  James G Wright,et al.  A Population-Based Nested Case-Control Study of the Costs of Hip and Knee Replacement Surgery , 2009, Medical care.