Magnetometry of injury currents from human nerve and muscle specimens using Superconducting Quantum Interferences Devices

Acute lesions of polarized membranes lead to slowly decaying ('near-DC') injury currents driven by the transmembrane resting potential gradient. Here we report the first recordings of injury-related near-DC magnetic fields from human nerve and muscle specimens in vitro using Superconducting Quantum Interference Devices (SQUIDs) operated in a conventional magnetically shielded room in a clinical environment. The specimen position was modulated sinusoidally beneath the sensor array by a non-magnetically fabricated scissors lift to improve the signal-to-noise ratio for near-DC fields. Depending on the specimen geometry the field patterns showed dipolar or quadrupolar aspects. The slow decay of human nerve and muscle injury currents was monitored for several hours from a distance of a few centimeters. Thus DC-magnetometry provides a sensitivity which might allow the remote detection of injury currents also in vivo.

[1]  K D Wolff,et al.  Non-invasive neuromagnetic monitoring of nerve and muscle injury currents. , 1993, Electroencephalography and clinical neurophysiology.

[2]  R B Borgens,et al.  Large and persistent electrical currents enter the transected lamprey spinal cord. , 1980, Proceedings of the National Academy of Sciences of the United States of America.

[3]  K. R. Robinson,et al.  The distribution of free calcium in transected spinal axons and its modulation by applied electrical fields , 1990, The Journal of neuroscience : the official journal of the Society for Neuroscience.

[4]  Richard Nuccitelli,et al.  AN ULTRASENSITIVE VIBRATING PROBE FOR MEASURING STEADY EXTRACELLULAR CURRENTS , 1974, The Journal of cell biology.

[5]  K. Hossmann,et al.  Cortical Negative DC Deflections following Middle Cerebral Artery Occlusion and KCl-Induced Spreading Depression: Effect on Blood Flow, Tissue Oxygenation, and Electroencephalogram , 1994, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[6]  Peter K. Stys,et al.  Compound action potential of nerve recorded by suction electrode: a theoretical and experimental analysis , 1991, Brain Research.

[7]  Gabriel Curio,et al.  Entwicklung einer mechanischen Bewegungseinrichtung zur Modulation DC-naher biomagnetischer Felder , 1996 .

[8]  G. Mies,et al.  Repeated Negative DC Deflections in Rat Cortex following Middle Cerebral Artery Occlusion are Abolished by MK-801: Effect on Volume of Ischemic Injury , 1992, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[9]  P Black,et al.  Spontaneous spinal cord "injury potential" in the rat. , 1985, Neurosurgery.

[10]  D. Drung The PTB 83-SQUID system for biomagnetic applications in a clinic , 1995, IEEE Transactions on Applied Superconductivity.

[11]  N Tepley,et al.  Magnetoencephalography of Focal Cerebral Ischemia in Rats , 1992, Stroke.

[12]  Richard Nuccitelli,et al.  A computerized 2-dimensional vibrating probe for mapping extracellular current patterns , 1992, Journal of Neuroscience Methods.