Small Coronary Vessel Pressure and Diameter in an Intact Beating Rabbit Heart Using Fixed‐Position and Free‐Motion Techniques

We evaluated a technique to measure small vessel pressures and diameters in the right ventricle of a beating rabbit heart. The method allowed free motion of the heart while these measurements were performed. This was accomplished with a strobed light source synchronized with the heart. Thus the observer “sees” the vessels only at the same point in the cardiac cycle. By slowly advancing the Btrobe pulse, we were able to visualize an entire cardiac cycle. We performed pressure measurements with an electromechanical micromanipulator that was programmed to synchronize the motion of a micropipette to the motion of a small vessel. For comparison, another technique was also used which fixed a portion of the right ventricle and allowed motion to be centered around this fixed point. Pressures in veins by our use of the free-motion and fixed techniques were compared and found to be statistically different (6.8 ± 0.7 compared to 13.5 ± 4.7 mm Hg, P< 0.01) with the free-motion technique recording the lower values. The phasic relationship between venous diameter variation and left ventricular pressure also was determined. This relationship was variable between venous networks but quite consistent within a network. The relationship between vessel pressure and vessel diameter revealed significant declines in pressure in relatively large vessels (< 140 μn). This free-motion technique can be used to provide information concerning not only the normal physiology of the coronary circulation, in terms of pressure distributions and the effects of extravascular pressure, but also the changes in vascular pressure which occur in ischemic myocardium and other tissues with inherent motion.

[1]  W. R. Tompkins,et al.  Pressure measurements in the mammalian microvasculature. , 1970, Microvascular research.

[2]  R. Bing,et al.  Total and Nutritional Coronary Flow , 1971, Circulation research.

[3]  R. F. Rushmer,et al.  PULSATILE PRESSURES IN THE MICROCIRCULATION OF FROG'S MESENTERY. , 1964, The American journal of physiology.

[4]  R. Bing,et al.  Studies on the coronary microcirculation by direct visualization. , 1972, The American journal of cardiology.

[5]  Dennis,et al.  Dynamic pressures in the pial arterial microcirculation. , 1971, The American journal of physiology.

[6]  D. Stromberg,et al.  Pressures in the Pial Arterial Microcirculation of the Cat during Changes in Systemic Arterial Blood Pressure , 1972, Circulation research.

[7]  K. Kato,et al.  Phasic coronary blood flow patterns as related to the balance between oxygen demand and supply in the myocardium. , 1976, Japanese heart journal.

[8]  E. Proctor An oxygenator for cardiopulmonary bypass in the rat. , 1977, Journal of Surgical Research.

[9]  R. Patterson,et al.  Phasic Right Coronary Artery Blood Flow in Conscious Dogs with Normal and Elevated Right Ventricular Pressures , 1976, Circulation research.

[10]  C. Wiggers,et al.  THE ALLEGED VALIDITY OF CORONARY SINUS OUTFLOW AS A CRITERION OF CORONARY REACTIONS , 1936 .

[11]  R. Bing,et al.  Studies of the coronary microcirculation of the cat. , 1971, The American journal of cardiology.

[12]  J M Fauvel,et al.  Microcirculation in the Ventricle of the Dog and Turtle , 1974, Circulation research.

[13]  J. Gross,et al.  Network model of pulsatile hemodynamics in the microcirculation of the rabbit omentum. , 1974, The American journal of physiology.