Real-time MR artifacts filtering during continuous EEG/fMRI acquisition.

The purpose of this study was the development of a real-time filtering procedure of MRI artifacts in order to monitor the EEG activity during continuous EEG/fMRI acquisition. The development of a combined EEG and fMRI technique has increased in the past few years. Preliminary "spike-triggered" applications have been possible because in this method, EEG knowledge was only necessary to identify a trigger signal to start a delayed fMRI acquisition. In this way, the two methods were used together but in an interleaved manner. In real simultaneous applications, like event-related fMRI study, artifacts induced by MRI events on EEG traces represent a substantial obstacle for a right analysis. Up until now, the methods proposed to solve this problem are mainly based on procedures to remove post-processing artifacts without the possibility to control electrophysiological behavior of the patient during fMRI scan. Moreover, these methods are not characterized by a strong "prior knowledge" of the artifact, which is an imperative condition to avoid any loss of information on the physiological signals recovered after filtering. In this work, we present a new method to perform simultaneous EEG/fMRI study with real-time artifacts filtering characterized by a procedure based on a preliminary analytical study of EPI sequence parameters-related EEG-artifact shapes. Standard EEG equipment was modified in order to work properly during ultra-fast MRI acquisitions. Changes included: high-performance acquisition device; electrodes/cap/wires/cables materials and geometric design; shielding box for EEG signal receiver; optical fiber link; and software. The effects of the RF pulse and time-varying magnetic fields were minimized by using a correct head cap wires-locked environment montage and then removed during EEG/fMRI acquisition with a subtraction algorithm that takes in account the most significant EPI sequence parameters. The on-line method also allows a further post-processing utilization.

[1]  M R Symms,et al.  EEG-triggered functional MRI of interictal epileptiform activity in patients with partial seizures. , 1999, Brain : a journal of neurology.

[2]  J R Ives,et al.  EEG-triggered echo-planar functional MRI in epilepsy , 1996, Neurology.

[3]  Mark S. Cohen,et al.  Acquiring simultaneous EEG and functional MRI , 2000, Clinical Neurophysiology.

[4]  Louis Lemieux,et al.  Identification of EEG Events in the MR Scanner: The Problem of Pulse Artifact and a Method for Its Subtraction , 1998, NeuroImage.

[5]  L. Lemieux,et al.  Recording of EEG during fMRI experiments: Patient safety , 1997, Magnetic resonance in medicine.

[6]  J. R. Baker,et al.  Simultaneous functional magnetic resonance imaging and electrophysiological recording , 1995 .

[7]  Robert Turner,et al.  A Method for Removing Imaging Artifact from Continuous EEG Recorded during Functional MRI , 2000, NeuroImage.

[8]  R. Edelman,et al.  Magnetic resonance imaging (2) , 1993, The New England journal of medicine.

[9]  J. Gotman,et al.  Quality of EEG in simultaneous EEG-fMRI for epilepsy , 2003, Clinical Neurophysiology.

[10]  Douglas C Noll,et al.  A modified electrode cap for EEG recordings in MRI scanners , 1999, Clinical Neurophysiology.

[11]  J. Hogg Magnetic resonance imaging. , 1994, Journal of the Royal Naval Medical Service.

[12]  P. Strobach,et al.  Event-synchronous cancellation of the heart interference in biomedical signals , 1994, IEEE Transactions on Biomedical Engineering.

[13]  Kenneth G. Jordan,et al.  An assessment of nonconvulsive seizures in the intensive care unit using continuous EEG monitoring , 1996, Neurology.

[14]  S Warach,et al.  Monitoring the patient's EEG during echo planar MRI. , 1993, Electroencephalography and clinical neurophysiology.

[15]  K J Werhahn,et al.  Electroencephalography during functional echo‐planar imaging: Detection of epileptic spikes using post‐processing methods , 2000, Magnetic resonance in medicine.