Source localization from axial image sets by iterative relaxation of the nearest neighbor criterion.
暂无分享,去创建一个
J J Prete | W S Bice | D F Dubois | B R Prestidge | B. Prestidge | J. J. Prete | W. Bice | D. Dubois
[1] R L Siddon,et al. Two-film brachytherapy reconstruction algorithm. , 1985, Medical physics.
[2] G T Chen,et al. A new source localization algorithm with no requirement of one-to-one source correspondence between biplane radiographs. , 1996, Medical physics.
[3] M A Moerland,et al. Evaluation of permanent I-125 prostate implants using radiography and magnetic resonance imaging. , 1997, International journal of radiation oncology, biology, physics.
[4] M D Altschuler,et al. Rapid, accurate, three-dimensional location of multiple sees in implant radiotherapy treatment planning. , 1983, Physics in medicine and biology.
[5] H. A. Hughes. Accuracy of foreign body localisation from tube-shift radiographs. , 1956, The British journal of radiology.
[6] H I Amols,et al. A three-film technique for reconstruction of radioactive seed implants. , 1981, Medical physics.
[7] J J Prete,et al. Comparison of MRI- and CT-based post-implant dosimetric analysis of transperineal interstitial permanent prostate brachytherapy. , 1998, Radiation oncology investigations.
[8] L. Fitzgerald,et al. Analysis of errors in three-dimensional reconstruction of radium implants from stereo radiographs. , 1975, Radiology.
[9] M S Rosenthal,et al. An automatic seed identification technique for interstitial implants using three isocentric radiographs. , 1983, Medical physics.
[10] C C Ling,et al. A CT-based evaluation method for permanent implants: application to prostate. , 1993, International journal of radiation oncology, biology, physics.
[11] B. Prestidge,et al. Clinical impact of implementing the recommendations of AAPM Task Group 43 on permanent prostate brachytherapy using 125I. American Association of Physicists in Medicine. , 1998, International journal of radiation oncology, biology, physics.
[12] M D Altschuler,et al. Semiautomated matching and seed position location for implanted ribbons. , 1994, Medical physics.
[13] C A Kelsey,et al. The effect of geometric errors in the reconstruction of iridium-192 seed implants. , 1982, Medical physics.
[14] D D Leavitt,et al. Computed tomography treatment planning in IR-192 brachytherapy in the head and neck. , 1992, International journal of radiation oncology, biology, physics.
[15] P J Biggs,et al. Geometric reconstruction of seed implants using a three-film technique. , 1983, Medical physics.
[16] L. Anderson,et al. Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No. 43 , 1995 .
[17] P. Schönemann,et al. A generalized solution of the orthogonal procrustes problem , 1966 .