Accuracy of real-time MR temperature mapping in the brain: a comparison of fast sequences.

PURPOSE To compare magnetic resonance (MR) thermometry based on the proton resonance frequency (PRF) method using a single shot echoplanar imaging (ss EPI) sequence to both of the standard sequences, gradient echo (GRE) and segmented echoplanar imaging (seg EPI) in the in vivo human brain, at 1.5T and 3T. MATERIAL AND METHODS Repetitive MR thermometry was performed on the brain of six volunteers using GRE, seg EPI, and ss EPI sequences on whole-body 1.5T and 3T clinical systems using comparable acquisition parameters. Phase stability and temperature data precision in the human head were determined over 12 min for the three sequences at both field strengths. An ex-vivo swine skeletal muscle model was used to evaluate temperature accuracy of the ss EPI sequence during heating by high intensity focused ultrasound (HIFU). RESULTS In-vivo examinations of brain revealed an average temperature precision of 0.37 °C/0.39 °C/0.16 °C at 3T for the GRE/seg EPI/ss EPI sequences. At 1.5T, a precision of 0.58 °C/0.63 °C/0.21 °C was achieved. In the ex-vivo swine model, a strong correlation of temperature data derived using ss EPI and GRE sequences was found with a temperature deviation <1 °C. CONCLUSION The ss EPI sequence was the fastest and the most precise sequence for MR thermometry, with significantly higher accuracy compared to GRE.

[1]  N. J. Shah,et al.  Magnetic field dependence of the distribution of NMR relaxation times in the living human brain , 2008, Magnetic Resonance Materials in Physics, Biology and Medicine.

[2]  J. Sahuquillo,et al.  Cooling the injured brain: how does moderate hypothermia influence the pathophysiology of traumatic brain injury. , 2007, Current pharmaceutical design.

[3]  Fritz Schick,et al.  Magnetic susceptibility effects on the accuracy of MR temperature monitoring by the proton resonance frequency method , 2005, Journal of magnetic resonance imaging : JMRI.

[4]  René M. Botnar,et al.  Temperature quantification using the proton frequency shift technique: In vitro and in vivo validation in an open 0.5 tesla interventional MR scanner during RF ablation , 2001, Journal of magnetic resonance imaging : JMRI.

[5]  P. Safar,et al.  Therapeutic hypothermia in traumatology. , 1999, The Surgical clinics of North America.

[6]  Alexandru Cernicanu,et al.  Validation of fast MR thermometry at 1.5 T with gradient‐echo echo planar imaging sequences: phantom and clinical feasibility studies , 2008, NMR in biomedicine.

[7]  K. Vigen,et al.  In vivo porcine liver radiofrequency ablation with simultaneous MR temperature imaging , 2006, Journal of magnetic resonance imaging : JMRI.

[8]  P van Gelderen,et al.  Fast magnetic-resonance temperature imaging. , 1996, Journal of magnetic resonance. Series B.

[9]  M. Mack,et al.  [MR thermometry for laser-induced thermotherapy at 1.5 Tesla]. , 2007, RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin.

[10]  K Butts,et al.  Catheter-based ultrasound applicators for selective thermal ablation: progress towards MRI-guided applications in prostate , 2004, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[11]  Natalia Vykhodtseva,et al.  500‐element ultrasound phased array system for noninvasive focal surgery of the brain: A preliminary rabbit study with ex vivo human skulls , 2004, Magnetic resonance in medicine.

[12]  H. Ishikura,et al.  Successful use of prolonged mild hypothermia in a patient with severe head injury and diffuse brain swelling. Case report. , 2007, Neurologia medico-chirurgica.

[13]  Marko Kangasniemi,et al.  Interleaved echo‐planar imaging for fast multiplanar magnetic resonance temperature imaging of ultrasound thermal ablation therapy , 2004, Journal of magnetic resonance imaging : JMRI.

[14]  S. Schoenberg,et al.  Measurement of signal‐to‐noise ratios in MR images: Influence of multichannel coils, parallel imaging, and reconstruction filters , 2007, Journal of magnetic resonance imaging : JMRI.

[15]  S. Okuda,et al.  Temperature mapping using the water proton chemical shift: Self‐referenced method with echo‐planar spectroscopic imaging , 2000, Magnetic resonance in medicine.

[16]  R M Harrison,et al.  A comparison of two methods for measuring the signal to noise ratio on MR images , 1999, Physics in medicine and biology.

[17]  M. Holzer,et al.  Mild resuscitative hypothermia to improve neurological outcome after cardiac arrest. A clinical feasibility trial. Hypothermia After Cardiac Arrest (HACA) Study Group. , 2000, Stroke.

[18]  Hans Stødkilde-Jørgensen,et al.  MRI-guided focused ultrasound: methodology and applications , 2006, IEEE Transactions on Medical Imaging.

[19]  J. Poorter,et al.  Noninvasive MRI Thermometry with the Proton Resonance Frequency (PRF) Method: In Vivo Results in Human Muscle , 1995, Magnetic resonance in medicine.

[20]  S. Renowden,et al.  Mild Hypothermia and the Distribution of Cerebral Lesions in Neonates With Hypoxic-Ischemic Encephalopathy , 2005, Pediatrics.

[21]  Joanne Markham,et al.  Precision, signal‐to‐noise ratio, and dose optimization of magnitude and phase arterial input functions in dynamic susceptibility contrast MRI , 2007, Journal of magnetic resonance imaging : JMRI.

[22]  Bruno Quesson,et al.  Magnetic resonance temperature imaging for guidance of thermotherapy , 2000, Journal of magnetic resonance imaging : JMRI.

[23]  F. Ye,et al.  Correction for geometric distortion and N/2 ghosting in EPI by phase labeling for additional coordinate encoding (PLACE) , 2007, Magnetic resonance in medicine.

[24]  A. Roggan,et al.  Percutaneous MR imaging-guided laser-induced thermotherapy of hepatic metastases , 2001 .

[25]  J H Kim,et al.  Clinical and biological studies of localized hyperthermia. , 1979, Cancer research.

[26]  Kagayaki Kuroda,et al.  Non-invasive MR thermography using the water proton chemical shift , 2005, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[27]  Bruno Quesson,et al.  Stability of real‐time MR temperature mapping in healthy and diseased human liver , 2004, Journal of magnetic resonance imaging : JMRI.

[28]  J S Lewin,et al.  A method for simultaneous RF ablation and MRI , 1998, Journal of magnetic resonance imaging : JMRI.

[29]  Bruno Quesson,et al.  Three‐dimensional spatial and temporal temperature control with MR thermometry‐guided focused ultrasound (MRgHIFU) , 2009, Magnetic resonance in medicine.

[30]  J. Hindman,et al.  Proton Resonance Shift of Water in the Gas and Liquid States , 1966 .

[31]  H. Quick,et al.  Temperature mapping of magnetic resonance‐guided laser interstitial thermal therapy (LITT) in lymphangiomas of the head and neck , 2000, Lasers in surgery and medicine.

[32]  K. Eichler,et al.  Interventional MR: interstitial therapy , 1999, European Radiology.

[33]  N. McDannold Quantitative MRI-based temperature mapping based on the proton resonant frequency shift: Review of validation studies , 2005, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[34]  Bruno Quesson,et al.  Real‐time MR temperature mapping of rabbit liver in vivo during thermal ablation , 2003, Magnetic resonance in medicine.

[35]  S. Bernard,et al.  Treatment of comatose survivors of out-of-hospital cardiac arrest with induced hypothermia. , 2002, The New England journal of medicine.

[36]  Martin G Mack,et al.  MR-guided ablation of head and neck tumors. , 2002, Neuroimaging clinics of North America.

[37]  K. Kuroda,et al.  A precise and fast temperature mapping using water proton chemical shift , 1995, Magnetic resonance in medicine.