Human brain: reliability and reproducibility of pulsed arterial spin-labeling perfusion MR imaging.

The Committee of Human Research of the University of California San Francisco approved this study, and all volunteers provided written informed consent. The goal of this study was to prospectively determine the global and regional reliability and reproducibility of noninvasive brain perfusion measurements obtained with different pulsed arterial spin-labeling (ASL) magnetic resonance (MR) imaging methods and to determine the extent to which within-subject variability and random noise limit reliability and reproducibility. Thirteen healthy volunteers were examined twice within 2 hours. The pulsed ASL methods compared in this study differ mainly with regard to magnetization transfer and eddy current effects. There were two main results: (a) Pulsed ASL MR imaging consistently had high measurement reliability (intraclass correlation coefficients greater than 0.75) and reproducibility (coefficients of variation less than 8.5%), and (b) random noise rather than within-subject variability limited reliability and reproducibility. It was concluded that low signal-to-noise ratios substantially limit the reliability and reproducibility of perfusion measurements.

[1]  E M Wilson,et al.  133Xenon Inhalation Method Analysis of Reproducibility: Some of Its Physiological Implications , 1977, Stroke.

[2]  J. Fleiss,et al.  Intraclass correlations: uses in assessing rater reliability. , 1979, Psychological bulletin.

[3]  R M Henkelman,et al.  Elimination of transverse coherences in FLASH MRI , 1988, Magnetic resonance in medicine.

[4]  J. Mugler,et al.  Rapid three‐dimensional T1‐weighted MR imaging with the MP‐RAGE sequence , 1991, Journal of magnetic resonance imaging : JMRI.

[5]  D. S. Williams,et al.  Magnetic resonance imaging of perfusion using spin inversion of arterial water. , 1992, Proceedings of the National Academy of Sciences of the United States of America.

[6]  A G Webb,et al.  Applications of reduced‐encoding MR imaging with generalized‐series reconstruction (RIGR) , 1993, Journal of magnetic resonance imaging : JMRI.

[7]  Donald S. Williams,et al.  NMR Measurement of Perfusion Using Arterial Spin Labeling Without Saturation of Macromolecular Spins , 1995, Magnetic resonance in medicine.

[8]  Seong-Gi Kim Quantification of relative cerebral blood flow change by flow‐sensitive alternating inversion recovery (FAIR) technique: Application to functional mapping , 1995, Magnetic resonance in medicine.

[9]  P. Jezzard,et al.  Correction for geometric distortion in echo planar images from B0 field variations , 1995, Magnetic resonance in medicine.

[10]  J A Frank,et al.  Perfusion imaging with compensation for asymmetric magnetization transfer effects , 1996, Magnetic resonance in medicine.

[11]  A Weindl,et al.  Deactivation of human visual cortex during involuntary ocular oscillations. A PET activation study. , 1996, Brain : a journal of neurology.

[12]  R. Buxton,et al.  Implementation of quantitative perfusion imaging techniques for functional brain mapping using pulsed arterial spin labeling , 1997, NMR in biomedicine.

[13]  R R Edelman,et al.  EPISTAR MRI: Multislice mapping of cerebral blood flow , 1998, Magnetic resonance in medicine.

[14]  P. Bandettini,et al.  QUIPSS II with thin‐slice TI1 periodic saturation: A method for improving accuracy of quantitative perfusion imaging using pulsed arterial spin labeling , 1999, Magnetic resonance in medicine.

[15]  Jeff Duyn,et al.  H215O PET validation of steady‐state arterial spin tagging cerebral blood flow measurements in humans , 2000, Magnetic resonance in medicine.

[16]  G. Andersson,et al.  Regional cerebral blood flow during tinnitus: a PET case study with lidocaine and auditory stimulation. , 2000, Acta oto-laryngologica.

[17]  W G Hopkins,et al.  Measures of Reliability in Sports Medicine and Science , 2000, Sports medicine.

[18]  G. Glover,et al.  Physiological noise in oxygenation‐sensitive magnetic resonance imaging , 2001, Magnetic resonance in medicine.

[19]  J D Pickard,et al.  Reproducibility of quantitative CT perfusion imaging. , 2001, The British journal of radiology.

[20]  Timothy J Carroll,et al.  Absolute Quantification of Cerebral Blood Flow with Magnetic Resonance, Reproducibility of the Method, and Comparison with H215O Positron Emission Tomography , 2002, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[21]  Narter Ari,et al.  Test‐retest reproducibility of quantitative CBF measurements using FAIR perfusion MRI and acetazolamide challenge , 2002, Magnetic resonance in medicine.

[22]  K. Zou,et al.  Quantitative analysis of MRI signal abnormalities of brain white matter with high reproducibility and accuracy , 2002, Journal of magnetic resonance imaging : JMRI.

[23]  N. Schuff,et al.  Improved perfusion‐weighted MRI by a novel double inversion with proximal labeling of both tagged and control acquisitions , 2003, Magnetic resonance in medicine.

[24]  S. Warach,et al.  Noninvasive perfusion imaging of human brain tumors with EPISTAR , 2004, European Radiology.