Chemiluminescence reaction kinetics-resolved multianalyte immunoassay strategy using a bispecific monoclonal antibody as the unique recognition reagent.

The multianalyte immunoassay (MIA) has attracted increasing attention due to its high sample throughput, short assay time, low sample consumption, and reduced overall cost. However, up to now, the reported MIA methods commonly require multiple antibodies since each antibody can recognize only one antigen. Herein, a novel bispecific monoclonal antibody (BsMcAb) that could bind methyl parathion and imidacloprid simultaneously was produced by a hybrid hybridomas strategy. A chemiluminescence (CL) reaction kinetics-resolved strategy was designed for MIA of methyl parathion and imidacloprid using the BsMcAb as the unique recognition reagent. Horseradish peroxidase (HRP) and alkaline phosphatase (ALP) were adopted as the signal probes to tag the haptens of the two pesticides due to their very different CL kinetic characteristics. After competitive immunoreactions, the HRP-tagged methyl parathion hapten and the ALP-tagged imidacloprid hapten were simultaneously bound to the BsMcAb since there were two different antigen-binding sites in it. Then, two CL reactions were simultaneously triggered by adding the CL coreactants, and the signals for methyl parathion and imidacloprid detections were collected at 0.6 and 1000 s, respectively. The linear ranges for methyl parathion and imidacloprid were both 1.0-500 ng/mL, with detection limits of 0.33 ng/mL (S/N = 3). The proposed method was successfully used to detect pesticides spiked in ginseng and American ginseng with acceptable recoveries of 80-118%. This proof-of-principle work demonstrated the feasibility of MIA using only one antibody.

[1]  M R Suresh,et al.  Novel bispecific immunoprobe for rapid and sensitive detection of prostate-specific antigen. , 1997, Clinical chemistry.

[2]  Dan Du,et al.  A bare-eye-based lateral flow immunoassay based on the use of gold nanoparticles for simultaneous detection of three pesticides , 2014, Microchimica Acta.

[3]  I. Kumagai,et al.  Zinc oxide-coated plasmonic chip modified with a bispecific antibody for sensitive detection of a fluorescent labeled-antigen. , 2011, Analytical chemistry.

[4]  Peter G Schultz,et al.  Targeting human C-type lectin-like molecule-1 (CLL1) with a bispecific antibody for immunotherapy of acute myeloid leukemia. , 2014, Angewandte Chemie.

[5]  Jun‐Jie Zhu,et al.  Ultrasensitive multianalyte electrochemical immunoassay based on metal ion functionalized titanium phosphate nanospheres. , 2012, Analytical chemistry.

[6]  A. Ebens,et al.  Antitumor efficacy of a bispecific antibody that targets HER2 and activates T cells. , 2014, Cancer research.

[7]  Dan Xu,et al.  Production and characterization of monoclonal antibody for class-specific determination of O,O-dimethyl organophosphorus pesticides and effect of heterologous coating antigens on immunoassay sensitivity. , 2009 .

[8]  J. Rusling,et al.  Fabrication of immunosensor microwell arrays from gold compact discs for detection of cancer biomarker proteins. , 2012, Lab on a chip.

[9]  M. Nielen,et al.  Multiplex screening of persistent organic pollutants in fish using spectrally encoded microspheres. , 2011, Analytical chemistry.

[10]  A. Berlina,et al.  'Traffic light' immunochromatographic test based on multicolor quantum dots for the simultaneous detection of several antibiotics in milk. , 2015, Biosensors & bioelectronics.

[11]  Fanggui Ye,et al.  Magnetic bead-sensing-platform-based chemiluminescence resonance energy transfer and its immunoassay application. , 2012, Analytical chemistry.

[12]  E. Wolf,et al.  Cloned transgenic farm animals produce a bispecific antibody for T cell-mediated tumor cell killing. , 2004, Proceedings of the National Academy of Sciences of the United States of America.

[13]  Reinhard Niessner,et al.  Detection of Escherichia coli O157:H7, Salmonella typhimurium, and Legionella pneumophila in water using a flow-through chemiluminescence microarray readout system. , 2008, Analytical chemistry.

[14]  David W Williams,et al.  Bispecific antibody-mediated detection of the Staphylococcus aureus thermonuclease. , 2012, Analytical chemistry.

[15]  Peter G Schultz,et al.  Synthesis of bispecific antibodies using genetically encoded unnatural amino acids. , 2012, Journal of the American Chemical Society.

[16]  Michael S Wilson,et al.  Electrochemical multianalyte immunoassays using an array-based sensor. , 2006, Analytical chemistry.

[17]  K. Matsumoto,et al.  Synthesis of a terbium fluorescent chelate and its application to time-resolved fluoroimmunoassay. , 2001, Analytical chemistry.

[18]  Jaw-Yuan Wang,et al.  One-step mixing with humanized anti-mPEG bispecific antibody enhances tumor accumulation and therapeutic efficacy of mPEGylated nanoparticles. , 2014, Biomaterials.

[19]  V. Balzani,et al.  Oscillating chemiluminescence from the reduction of bromate by malonic acid catalyzed by tris(2,2'-bipyridine)ruthenium(II) , 1982 .

[20]  S. Brack,et al.  A Bispecific HER2-Targeting FynomAb with Superior Antitumor Activity and Novel Mode of Action , 2014, Molecular Cancer Therapeutics.

[21]  H. Ju,et al.  Sampling-resolution strategy for one-way multiplexed immunoassay with sequential chemiluminescent detection. , 2008, Analytical chemistry.

[22]  Feng Yan,et al.  Chemiluminescence imaging immunoassay of multiple tumor markers for cancer screening. , 2012, Analytical chemistry.

[23]  J. Rusling,et al.  Carbon nanotube microwell array for sensitive electrochemiluminescent detection of cancer biomarker proteins. , 2011, Analytical chemistry.

[24]  Jie Wu,et al.  Multilayer hemin/G-quadruplex wrapped gold nanoparticles as tag for ultrasensitive multiplex immunoassay by chemiluminescence imaging. , 2013, Biosensors & bioelectronics.