System for intraoperative evaluation of soft-tissue-generated forces during total hip arthroplasty by measurement of the pressure distribution in artificial joints
暂无分享,去创建一个
Naoki Suzuki | Mitsuyoshi Yamamura | Nobuhiko Sugano | Hidenobu Miki | Asaki Hattori | Kazuo Yonenobu | Takahiro Ochi | Yoshito Otake | N. Suzuki | A. Hattori | K. Yonenobu | Y. Otake | N. Sugano | T. Ochi | H. Miki | M. Yamamura
[1] W. A. Hodge,et al. Contact pressures in the human hip joint measured in vivo. , 1986, Proceedings of the National Academy of Sciences of the United States of America.
[2] A Rohlmann,et al. Multichannel strain gauge telemetry for orthopaedic implants. , 1988, Journal of biomechanics.
[3] G. Bergmann,et al. Hip joint loading during walking and running, measured in two patients. , 1993, Journal of biomechanics.
[4] S. Delp,et al. Superior displacement of the hip in total joint replacement: Effects of prosthetic neck length, neck‐stem angle, and anteversion angle on the moment‐generating capacity of the muscles , 1994, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.
[5] A. Duquennoy,et al. CAUSES OF DISLOCATION OF TOTAL HIP ARTHROPLASTY , 1994 .
[6] A. Cotten,et al. Causes of dislocation of total hip arthroplasty. CT study of component alignment. , 1994, The Journal of bone and joint surgery. British volume.
[7] T Nishii,et al. Computed-tomography-based computer preoperative planning for total hip arthroplasty. , 1998, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.
[8] A Rohlmann,et al. Hip endoprosthesis for in vivo measurement of joint force and temperature. , 1999, Journal of biomechanics.
[9] D. D’Lima,et al. The Effect of the Orientation of the Acetabular and Femoral Components on the Range of Motion of the Hip at Different Head-Neck Ratios* , 2000, The Journal of bone and joint surgery. American volume.
[10] Philip C. Noble,et al. The Effect of Femoral Component Head Size on Posterior Dislocation of the Artificial Hip Joint* , 2000, The Journal of bone and joint surgery. American volume.
[11] J. S. Kim,et al. Strain distribution in the proximal human femur. An in vitro comparison in the intact femur and after insertion of reference and experimental femoral stems. , 2001, The Journal of bone and joint surgery. British volume.
[12] D. Vandevelde,et al. Reduction in Variability of Acetabular Cup Abduction Using Computer Assisted Surgery: A Prospective and Randomized Study , 2002, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.
[13] S. Hanusek,et al. Movement Mapping as dynamic preoperative surgical planning in total hip replacement , 2002, Archives of Orthopaedic and Trauma Surgery.
[14] A. Leali. Strain distribution in the proximal human femur. , 2002, The Journal of bone and joint surgery. British volume.
[15] G Bergmann,et al. Direct comparison of calculated hip joint contact forces with those measured using instrumented implants. An evaluation of a three-dimensional mathematical model of the lower limb. , 2003, Journal of biomechanics.
[16] Wolfgang J Parak,et al. Three-dimensional measurements of the pressure distribution in artificial joints with a capacitive sensor array. , 2004, Journal of biomechanics.
[17] Naoki Suzuki,et al. Four-dimensional model of the lower extremity after total hip arthroplasty. , 2005, Journal of biomechanics.
[18] N. Suzuki,et al. Estimation of dislocation after total hip arthroplasty by 4-dimensional. , 2005, Studies in health technology and informatics.