Critical Clearing Time Sensitivity for Inequality Constrained Systems

From a stability perspective, a renewable generation (RG)-rich power system is a constrained system. As the quasi-stability boundary of a constrained system is structurally very different from that of an unconstrained system, finding the sensitivity of critical clearing time (CCT) to change in system parameters is very beneficial for a constrained power system, especially for planning/revising constraints arising from system protection settings. In this paper, we derive the first order sensitivity of a constrained power system using trajectory sensitivities of fault-on and post-fault trajectories. The results for the test system demonstrate the dependence between ability to meet angle and frequency constraints, and change in power system parameters such as operating conditions and inertia.

[1]  Bin Wang,et al.  Can nonlinear electromechanical oscillation be analyzed using an equivalent SMIB system? , 2017, 2017 IEEE Power & Energy Society General Meeting.

[2]  M. A. Pai,et al.  A new approach to dynamic security assessment using trajectory sensitivities , 1997 .

[3]  K. L. Praprost,et al.  A stability theory for constrained dynamic systems with applications to electric power systems , 1994, Proceedings of 1994 American Control Conference - ACC '94.

[4]  Vijay Vittal,et al.  Cluster Computing-Based Trajectory Sensitivity Analysis Application to the WECC System , 2012, IEEE Transactions on Power Systems.

[5]  James S. Thorp,et al.  Transient Stability Assessment of Cascade Tripping of Renewable Sources Using SOS , 2018, 2018 IEEE Power & Energy Society General Meeting (PESGM).

[6]  Ian A. Hiskens,et al.  Trajectory Sensitivity Analysis of Hybrid Systems , 2000 .

[7]  Heinz Schättler,et al.  Stability Regions for Differential-Algebraic Systems , 1992 .

[8]  R.J. Thomas,et al.  On voltage collapse in electric power systems , 1989, Conference Papers Power Industry Computer Application Conference.

[9]  James S. Thorp,et al.  Stability region estimation under low voltage ride through constraints using sum of squares , 2017, 2017 North American Power Symposium (NAPS).

[10]  H. Chiang Direct Methods for Stability Analysis of Electric Power Systems: Theoretical Foundation, BCU Methodologies, and Applications , 2010 .

[11]  S. Wiggins Introduction to Applied Nonlinear Dynamical Systems and Chaos , 1989 .

[12]  J. Thorp,et al.  Estimating Relevant Portion of Stability Region using Lyapunov Approach and Sum of Squares , 2017, 2018 IEEE Power & Energy Society General Meeting (PESGM).

[13]  Goran Andersson,et al.  Impact of Low Rotational Inertia on Power System Stability and Operation , 2013, 1312.6435.

[14]  I. Dobson,et al.  Sensitivity of Transient Stability Critical Clearing Time , 2018, IEEE Transactions on Power Systems.

[15]  Davide Lauria,et al.  Transient stability evaluation of multimachine power systems: a probabilistic approach based upon the extended equal area criterion , 1994 .

[16]  John M. Lee Introduction to Smooth Manifolds , 2002 .

[17]  Guanji Hou,et al.  Trajectory Sensitivity Based Power System Dynamic Security Assessment , 2012 .

[18]  Lamine Mili,et al.  Clarifications of the BCU method for transient stability analysis , 1995 .

[19]  Ian A. Hiskens,et al.  Sensitivity approaches for direct computation of critical parameters in a power system , 2002 .