3-D numerical simulation of blood flow through models of the human aorta.

A Spiral Computerized Tomography (CT) scan of the aorta were obtained from a single subject and three model variations were examined. Computational fluid dynamics modeling of all three models showed variations in the velocity contours along the aortic arch with differences in the boundary layer growth and recirculation regions. Further down-stream, all three models showed very similar velocity profiles during maximum velocity with differences occurring in the decelerating part of the pulse. Flow patterns obtained from transient 3-D computational fluid dynamics are influenced by different reconstruction methods and the pulsatility of the flow. Caution is required when analyzing models based on CT scans.

[1]  L. Labrousse,et al.  Mobile Thrombus of the Thoracic Aorta: Diagnosis and Treatment in 9 Cases , 2002, Annals of vascular surgery.

[2]  L. Talbot,et al.  Experimental study of wall shear rates in the entry region of a curved tube , 1978, Journal of Fluid Mechanics.

[3]  Jennifer Anne Moore,et al.  Accuracy Assessment of Computational Blood Flow Modelling in Realistic Arterial Geometries , 1998, Advances in Bioengineering.

[4]  K B Chandran,et al.  Flow dynamics in the human aorta. , 1993, Journal of biomechanical engineering.

[5]  W. Nichols McDonald's Blood Flow in Arteries , 1996 .

[6]  Timothy J. Pedley,et al.  The fluid mechanics of large blood vessels , 1980 .

[7]  C. R. Ethier,et al.  Factors Influencing Blood Flow Patterns in the Human Right Coronary Artery , 2001, Annals of Biomedical Engineering.

[8]  M. Walsh,et al.  Injection-Moulded Models of Major and Minor Arteries: The Variability of Model Wall Thickness Owing to Casting Technique , 2005, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[9]  J. Moore,et al.  Dynamic curvature strongly affects wall shear rates in a coronary artery bifurcation model. , 2001, Journal of biomechanics.

[10]  R. Sacco,et al.  Atherosclerotic disease of the aortic arch as a risk factor for recurrent ischemic stroke. , 1996, The New England journal of medicine.

[11]  T. Pedley The Fluid Mechanics of Large Blood Vessels: Contents , 1980 .

[12]  N. Wood,et al.  Velocity patterns in the aorta. , 1971, Cardiovascular research.

[13]  P. Amarenco,et al.  Atherosclerosis of the thoracic aorta: from risk stratification to treatment. , 2002, The American journal of cardiology.

[14]  D A Steinman,et al.  Computational blood flow modelling: errors associated with reconstructing finite element models from magnetic resonance images. , 1997, Journal of biomechanics.

[15]  M Ojha,et al.  Compliance mismatch may promote graft-artery intimal hyperplasia by altering suture-line stresses. , 1997, Journal of biomechanics.

[16]  V Deplano,et al.  Experimental and numerical study of pulsatile flows through stenosis: wall shear stress analysis. , 1999, Journal of biomechanics.

[17]  C. R. Ethier,et al.  A numerical study of blood flow patterns in anatomically realistic and simplified end-to-side anastomoses. , 1999, Journal of biomechanical engineering.

[18]  H. Falsetti,et al.  Sequential Velocity Development in the Ascending and Descending Aorta of the Dog , 1972, Circulation research.

[19]  R. Sacco,et al.  Impact of Aortic Stiffness on Ischemic Stroke in Elderly Patients , 2002, Stroke.

[20]  K. Shung,et al.  Ultrasonic backscattering from porcine whole blood of varying hematocrit and shear rate under pulsatile flow. , 1999, Ultrasound in medicine & biology.

[21]  T Naruse,et al.  Large curvature effect on pulsatile entrance flow in a curved tube: model experiment simulating blood flow in an aortic arch. , 1996, Journal of biomechanical engineering.

[22]  K. Chandran,et al.  Experimental study of physiological pulsatile flow in a curved tube , 1981, Journal of Fluid Mechanics.

[23]  M. Elkind,et al.  Leukocyte Count Is Associated With Aortic Arch Plaque Thickness , 2002, Stroke.

[24]  Jeffrey D. Hart,et al.  Nonparametric Smoothing and Lack-Of-Fit Tests , 1997 .

[25]  J. Weinberger Noninvasive imaging of atherosclerotic plaque in the arch of the aorta with transcutaneous B-mode ultrasonography. , 2002, Neuroimaging clinics of North America.

[26]  R. Nerem,et al.  An experimental study of the velocity distribution and transition to turbulence in the aorta , 1972, Journal of Fluid Mechanics.

[27]  W. R. Wagner,et al.  Correspondence: Grain boundaries in thin-film bicrystals of surface-reactive metals prepared by vacuum welding , 1974 .

[28]  L. Talbot,et al.  Pulsatile entrance flow in a curved pipe , 1983, Journal of Fluid Mechanics.

[29]  D J Doorly,et al.  The influence of out-of-plane geometry on pulsatile flow within a distal end-to-side anastomosis. , 2002, Journal of biomechanics.

[30]  J. Farey,et al.  XXXVI. On blasting with gunpowder , 1804 .

[31]  C. R. Ethier,et al.  Requirements for mesh resolution in 3D computational hemodynamics. , 2001, Journal of biomechanical engineering.

[32]  D. L. Fry Certain Histological and Chemical Responses of the Vascular Interface to Acutely Induced Mechanical Stress in the Aorta of the Dog , 1969, Circulation research.

[33]  L. Fahrmeir,et al.  Multivariate statistical modelling based on generalized linear models , 1994 .

[34]  A. Barakat,et al.  Unsteady and three-dimensional simulation of blood flow in the human aortic arch. , 2002, Journal of biomechanical engineering.

[35]  W. R. Dean XVI. Note on the motion of fluid in a curved pipe , 1927 .

[36]  R. Bouzerar,et al.  Blood flow patterns in an anatomically realistic coronary vessel: influence of three different reconstruction methods. , 2002, Journal of biomechanics.

[37]  K B Chandran,et al.  Physiological pulsatile flow experiments in a model of the human aortic arch. , 1982, Journal of biomechanics.

[38]  I. Kronzon,et al.  Effect of treatment on the incidence of stroke and other emboli in 519 patients with severe thoracic aortic plaque. , 2002, The American journal of cardiology.

[39]  Piero Tortoli,et al.  Toward a better quantitative measurement of aortic flow. , 2002, Ultrasound in medicine & biology.