Computed tomography perfusion imaging denoising using Gaussian process regression

Brain perfusion weighted images acquired using dynamic contrast studies have an important clinical role in acute stroke diagnosis and treatment decisions. However, computed tomography (CT) images suffer from low contrast-to-noise ratios (CNR) as a consequence of the limitation of the exposure to radiation of the patient. As a consequence, the developments of methods for improving the CNR are valuable. The majority of existing approaches for denoising CT images are optimized for 3D (spatial) information, including spatial decimation (spatially weighted mean filters) and techniques based on wavelet and curvelet transforms. However, perfusion imaging data is 4D as it also contains temporal information. Our approach using gaussian process regression (GPR), which takes advantage of the temporal information, to reduce the noise level. Over the entire image, GPR gains a 99% CNR improvement over the raw images and also improves the quality of haemodynamic maps allowing a better identification of edges and detailed information. At the level of individual voxel, GPR provides a stable baseline, helps us to identify key parameters from tissue time-concentration curves and reduces the oscillations in the curve. GPR is superior to the comparable techniques used in this study.

[1]  T. A. Bronikowski,et al.  Model-free deconvolution techniques for estimating vascular transport functions. , 1983, International journal of bio-medical computing.

[2]  Andrew P. Witkin,et al.  Scale-Space Filtering , 1983, IJCAI.

[3]  B. Rosen,et al.  High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part I: Mathematical approach and statistical analysis , 1996, Magnetic resonance in medicine.

[4]  B. Rosen,et al.  High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part II: Experimental comparison and preliminary results , 1996, Magnetic resonance in medicine.

[5]  A. Gjedde,et al.  Absolute Cerebral Blood Flow and Blood Volume Measured by Magnetic Resonance Imaging Bolus Tracking: Comparison with Positron Emission Tomography Values , 1998, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[6]  F. Ståhlberg,et al.  Assessment of regional cerebral blood flow by dynamic susceptibility contrast MRI using different deconvolution techniques , 2000, Magnetic resonance in medicine.

[7]  M. Wiesmann,et al.  Dynamic CT perfusion imaging of acute stroke. , 2000, AJNR. American journal of neuroradiology.

[8]  J. Thiran,et al.  Simultaneous measurement of regional cerebral blood flow by perfusion CT and stable xenon CT: a validation study. , 2001, AJNR. American journal of neuroradiology.

[9]  Emmanuel J. Candès,et al.  The curvelet transform for image denoising , 2001, Proceedings 2001 International Conference on Image Processing (Cat. No.01CH37205).

[10]  W. Yuh,et al.  Guidelines and recommendations for perfusion imaging in cerebral ischemia: A scientific statement for healthcare professionals by the writing group on perfusion imaging, from the Council on Cardiovascular Radiology of the American Heart Association. , 2003, Stroke.

[11]  J. Strzelczyk The Essential Physics of Medical Imaging , 2003 .

[12]  Amy Berrington de González,et al.  Risk of cancer from diagnostic X-rays: estimates for the UK and 14 other countries , 2004, The Lancet.

[13]  Gonzalo Pajares Martinsanz,et al.  A wavelet-based image fusion tutorial , 2004 .

[14]  M. Wintermark,et al.  Accuracy of dynamic perfusion CT with deconvolution in detecting acute hemispheric stroke. , 2005, AJNR. American journal of neuroradiology.

[15]  Emmanuel L Barbier,et al.  Comparative Overview of Brain Perfusion Imaging Techniques , 2005, Journal of neuroradiology. Journal de neuroradiologie.

[16]  M. Wintermark,et al.  Comparative overview of brain perfusion imaging techniques. , 2005, Stroke.

[17]  Rainer Raupach,et al.  Wavelet Based Noise Reduction by Identification of Correlations , 2006, DAGM-Symposium.

[18]  M. Bastin,et al.  Persistent Infarct Hyperintensity on Diffusion-Weighted Imaging Late After Stroke Indicates Heterogeneous, Delayed, Infarct Evolution , 2006, Stroke.

[19]  J. O’Sullivan,et al.  Properties of preprocessed sinogram data in x-ray computed tomography. , 2006, Medical physics.

[20]  Rainer Raupach,et al.  Separate CT-Reconstruction for Orientation and Position Adaptive Wavelet Denoising , 2007, Bildverarbeitung für die Medizin.

[21]  R. Sivakumar DENOISING OF COMPUTER TOMOGRAPHY IMAGES USING CURVELET TRANSFORM , 2007 .

[22]  M. Bastin,et al.  Acute ischemic stroke lesion measurement on diffusion-weighted imaging--important considerations in designing acute stroke trials with magnetic resonance imaging. , 2007, Journal of stroke and cerebrovascular diseases : the official journal of National Stroke Association.

[23]  A. Einstein,et al.  Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography. , 2007, JAMA.

[24]  Z. Sajjad Perfusion imaging in ischaemic stroke. , 2008, JPMA. The Journal of the Pakistan Medical Association.

[25]  Afra M. Wohlschläger,et al.  CT-perfusion imaging of the human brain: Advanced deconvolution analysis using circulant singular value decomposition , 2008, Comput. Medical Imaging Graph..

[26]  Carl E. Rasmussen,et al.  Gaussian processes for machine learning , 2005, Adaptive computation and machine learning.

[27]  B. van Ginneken,et al.  TIPS bilateral noise reduction in 4D CT perfusion scans produces high-quality cerebral blood flow maps , 2011, Physics in medicine and biology.

[28]  S Ali Hyder,et al.  An efficient algorithm for denoising MR and CT images using digital curvelet transform. , 2011, Advances in experimental medicine and biology.

[29]  Paola Coan,et al.  X-ray phase-contrast imaging: from pre-clinical applications towards clinics , 2013, Physics in medicine and biology.