Wireless Sensor Platform for Cultural Heritage Monitoring and Modeling System

Results from three years of continuous monitoring of environmental conditions using a wireless sensor platform installed at The Cloisters, the medieval branch of the New York Metropolitan Museum of Art, are presented. The platform comprises more than 200 sensors that were distributed in five galleries to assess temperature and air flow and to quantify microclimate changes using physics-based and statistical models. The wireless sensor network data shows a very stable environment within the galleries, while the dense monitoring enables localized monitoring of subtle changes in air quality trends and impact of visitors on the microclimate conditions. The high spatial and temporal resolution data serves as a baseline study to understand the impact of visitors and building operations on the long-term preservation of art objects.

[1]  H. Hamann,et al.  Data Center Metrology and Measurement-Based Modeling Methods , 2012 .

[2]  Lina M. Pestana Leão de Brito,et al.  Wireless Sensor Networks Applied to Museums' Environmental Monitoring , 2008, 2008 The Fourth International Conference on Wireless and Mobile Communications.

[3]  Eric May,et al.  Conservation science: heritage materials , 2006 .

[4]  Hendrik F. Hamann,et al.  Humidity Control and Dew Point Management , 2011 .

[5]  Paolo Dionisi-Vici,et al.  Long-term hygromechanical monitoring of Wooden Objects of Art (WOA): A tool for preventive conservation , 2013 .

[6]  Hiroshi Akima,et al.  A Method of Bivariate Interpolation and Smooth Surface Fitting for Irregularly Distributed Data Points , 1978, TOMS.

[7]  Wei Ye,et al.  Design and placement of light monitoring system in museums based on wireless sensor networks , 2011, 2011 International Symposium on Advanced Control of Industrial Processes (ADCONIP).

[8]  Lina M. P. L. Brito,et al.  The WISE -MUSE Project: Environmental Monitoring and Controlling of Museums based on Wireless Sensors Networks , 2009 .

[9]  Hl Henk Schellen,et al.  Application of an integrated indoor climate, HVAC and showcase model for the indoor climate performance of a museum , 2008 .

[10]  Massimo Andretta,et al.  Investigation on the interaction between the outdoor environment and the indoor microclimate of a historical library , 2016 .

[11]  F. Henriques,et al.  Microclimatic analysis of historic buildings: A new methodology for temperate climates , 2014 .

[12]  Angelo Chianese,et al.  SmaCH: A Framework for Smart Cultural Heritage Spaces , 2014, 2014 Tenth International Conference on Signal-Image Technology and Internet-Based Systems.

[13]  Refrigerating ASHRAE handbook. Heating, ventilating, and air-conditioning systems and equipment , 1992 .

[14]  R. Van Grieken,et al.  Environmental monitoring in four European museums , 2001 .

[15]  P. Rocca,et al.  A WSN-based architecture for the E-Museum - the experience at “Sala dei 500” in Palazzo Vecchio (Florence) , 2013, 2013 IEEE Antennas and Propagation Society International Symposium (APSURSI).

[16]  Jo Kirby Atkinson,et al.  Environmental conditions for the safeguarding of collections: A background to the current debate on the control of relative humidity and temperature , 2014 .

[17]  Denis Donlagic,et al.  Sensor for high-air-humidity measurement , 1996 .

[18]  Laura M. Rodríguez Peralta,et al.  Environmental Monitoring based on Wireless Sensor Network via Mobile Phone , 2013 .

[19]  Paolo Dionisi-Vici,et al.  An Analytical Method for the Determination of the Climatic Distance between Different Microclimates for the Conservation of Wooden Cultural Heritage Objects , 2011 .

[20]  Marion F. Mecklenburg,et al.  Micro cliMates and Moisture induced daMage to paintings , 2007 .

[21]  Rp Rick Kramer,et al.  A proposed method to assess the damage risk of future climate change to museum objects in historic buildings , 2012 .

[22]  Hossam S. Hassanein,et al.  Connectivity optimization with realistic lifetime constraints for node placement in environmental monitoring , 2009, 2009 IEEE 34th Conference on Local Computer Networks.

[23]  Slawomir Jakiela,et al.  Allowable thresholds in dynamic changes of microclimate for wooden cultural objects: monitoring in situ and modelling , 2005 .

[24]  Mark Gilberg,et al.  Analyzing the Impact of Protective Glazing on Stained Glass Windows , 2002 .

[25]  Anthony Tzes,et al.  Power Conservation through Energy Efficient Routing in Wireless Sensor Networks , 2009, Sensors.

[26]  Michel Dubus,et al.  Monitoring Copper and Silver Corrosion in Different Museum Environments by Electrical Resistance Measurement , 2010 .

[27]  Haley Fu,et al.  INVESTIGATION OF FACTORS THAT INFLUENCE CREEP CORROSION ON PRINTED CIRCUIT BOARDS , 2012 .

[28]  P. Gamba,et al.  Monitoring heritage buildings and artworks with Wireless Sensor Networks , 2012, 2012 IEEE Workshop on Environmental Energy and Structural Monitoring Systems (EESMS).

[29]  Natalie Williams Portal,et al.  Evaluation of heat and moisture induced stress and strain of historic building materials and artefacts , 2011 .

[30]  Matija Strlič,et al.  Pollution monitoring at heritage sites in developing and emerging economies , 2013 .

[31]  Amelia Peck,et al.  Period Rooms in The Metropolitan Museum of Art , 1996 .

[32]  F Raffaelli,et al.  The case study of The daughters of the Emperor Ferdinand I by Jakob Seisenegger, in Trento (Italy): analytical hygro-mechanical results as a support in risk assessment for technical interventions , 2016 .

[33]  M. F. Mecklenburg,et al.  Temperature and relative humidity effects on the mechanical and chemical stability of collections : Practical guide to HVAC for museums and historic renovation , 1999 .

[34]  Marion F. Mecklenburg,et al.  Determining the Acceptable Ranges of Relative Humidity And Temperature in Museums and Galleries: Part 1, Structural Response to Relative Humidity , 2007 .

[35]  Natalie Williams Portal,et al.  The multiphysics modeling of heat and moisture induced stress and strain of historic building materials and artefacts , 2014 .

[36]  John E. Mitchell,et al.  Remote Assessment of Cultural Heritage Environments with Wireless Sensor Array Networks , 2014, Sensors.

[37]  S. V. Kasmir Raja,et al.  QoS routing in wireless sensor networks—a survey , 2012, CSUR.

[38]  D. Coley,et al.  The implications of a changing climate for buildings , 2012 .

[39]  S. Landi,et al.  The maintenance in situ of architecturally related textiles , 1980 .

[40]  Madhusudan K. Iyengar,et al.  Uncovering energy-efficiency opportunities in data centers , 2009, IBM J. Res. Dev..

[41]  Łukasz Bratasz,et al.  Allowable microclimatic variations for painted wood , 2013 .

[42]  V. Matko,et al.  Temperature-compensated capacitance–frequency converter with high resolution , 2014 .

[43]  Joseph Sloan,et al.  Concealable strain sensing method for art preservation , 2014 .

[44]  H. F. Hamann,et al.  Corrosion risk management in IT facilities , 2012, 13th InterSociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems.

[45]  R. G. Newton A study of conditions in five ventilated double windows in cathedrals , 1980 .

[46]  Paul M. Whitmore,et al.  An Open-Source, Internet-of-Things Approach for Remote Sensing in Museums , 2016 .

[47]  Anamika Yadav,et al.  Fuzzy based adaptive congestion control in wireless sensor networks , 2013, 2013 Sixth International Conference on Contemporary Computing (IC3).

[48]  Vanessa Lopez Simulating Heat and Mass Transfer with Limited Amount of Sensor Data , 2016 .

[49]  P. Rocca,et al.  A multi-sensor WSN backbone for museum monitoring and surveillance , 2012, 2012 6th European Conference on Antennas and Propagation (EUCAP).