Catheter Kinematics for Intracardiac Navigation

Steerable catheters are utilized frequently in minimally invasive cardiac interventions. Despite their extensive applications, the properties of the steerable section of such devices have not been thoroughly investigated. In this paper, the kinematics of the distal shaft of the catheters is modeled, and the catheter's reachable workspace and its singular configurations are studied. The modeling is empirically validated through experiments with actual catheters mounted on a specialized robot. The statistical analysis of the experiments verify the effectiveness of the proposed model in estimating the catheter's tip position. In the experiments, the modeling error does not exceed 2.66 plusmn 1.96 mm, and the mean absolute error in position coordinates is less than 1.55 mm. In addition, the linear relationship between the model and the measured position vectors is demonstrated, and the significance of the modeling goodness of fit is established. Based on the precision and computational effectiveness of the method, the applicability of the modeling to control and simulation purposes is postulated.

[1]  Stephane Cotin,et al.  Interactive physically-based simulation of catheter and guidewire , 2006, Comput. Graph..

[2]  Ian D. Walker,et al.  Kinematics for multisection continuum robots , 2006, IEEE Transactions on Robotics.

[3]  Andrew Galbraith,et al.  A complete mock circulation loop for the evaluation of left, right, and biventricular assist devices. , 2005, Artificial organs.

[4]  Koji Ikuta,et al.  Multi-degree of freedom hydraulic pressure driven safety active catheter , 2006, Proceedings 2006 IEEE International Conference on Robotics and Automation, 2006. ICRA 2006..

[5]  Yusof Ganji,et al.  Catheter kinematics and control to enhance cardiac ablation , 2006, SPIE Optics East.

[6]  Ian D. Walker,et al.  Kinematics and the Implementation of an Elephant's Trunk Manipulator and Other Continuum Style Robots , 2003, J. Field Robotics.

[7]  Farrokh Janabi-Sharifi,et al.  Kinematic characterization of a cardiac ablation catheter , 2007, 2007 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[8]  Rajnikant V. Patel,et al.  Master-slave control of an active catheter instrumented with shape memory alloy actuators , 2007, 2007 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[9]  Koji Ikuta,et al.  Mobile virtual endoscope system with haptic and visual information for non-invasive inspection training , 2001, Proceedings 2001 ICRA. IEEE International Conference on Robotics and Automation (Cat. No.01CH37164).

[10]  Yacine Amirat,et al.  Modeling and Control of a Hybrid Continuum Active Catheter for Aortic Aneurysm Treatment , 2005, Proceedings of the 2005 IEEE International Conference on Robotics and Automation.

[11]  Masayoshi Esashi,et al.  Active catheter, active guide wire and related sensor systems , 2002, Proceedings of the 5th Biannual World Automation Congress.

[12]  Samuel Zoneraich Cardiology: An Illustrated Text/Reference, vol 1: Physiology, Pharmacology, Diagnosis, vol 2: Cardiovascular Disease , 1992 .

[13]  M. Rubin Cosserat Theories: Shells, Rods and Points , 2000 .

[14]  W. Niessen,et al.  Analytical guide wire motion algorithm for simulation of endovascular interventions , 2003, Medical and Biological Engineering and Computing.

[15]  W. Saliba,et al.  Novel Robotic Catheter Remote Control System: Feasibility and Safety of Transseptal Puncture and Endocardial Catheter Navigation , 2006, Journal of cardiovascular electrophysiology.

[16]  James H. Anderson,et al.  Simulation-based Virtual Prototyping of Customized Catheterization Devices , 2004, J. Comput. Inf. Sci. Eng..

[17]  J. Bruce C. Davies,et al.  Continuum robots - a state of the art , 1999, Proceedings 1999 IEEE International Conference on Robotics and Automation (Cat. No.99CH36288C).

[18]  S. Cotin,et al.  Designing a computer‐based simulator for interventional cardiology training , 2000, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[19]  Y. Haga,et al.  Small diameter hydraulic active bending catheter using laser processed super elastic alloy and silicone rubber tube , 2005, 2005 3rd IEEE/EMBS Special Topic Conference on Microtechnology in Medicine and Biology.

[20]  Bernhard Geiger,et al.  A Real-Time Deformable Model for Flexible Instruments Inserted into Tubular Structures , 2002, MICCAI.

[21]  Jean-François Brethé,et al.  Determination of the Repeatability of a Kuka Robot Using the Stochastic Ellipsoid Approach , 2005, Proceedings of the 2005 IEEE International Conference on Robotics and Automation.

[22]  Stephane Cotin,et al.  New Approaches to Catheter Navigation for Interventional Radiology Simulation , 2005, MICCAI.

[23]  Laurent Grisoni,et al.  Surgical thread simulation , 2002 .

[24]  V. Santinelli,et al.  Robotic magnetic navigation for atrial fibrillation ablation. , 2006, Journal of the American College of Cardiology.