Fault direction estimation in radial distribution system using phase-change in sequencecurrent

Summary form only given. This paper presents a method for estimating the direction of fault in such radial distribution systems using phase-change in current. The difference in phase angle between the positive sequence component of current during fault and prefault conditions has been found to be a good indicator of the fault direction in a three phase system. A rule base formed for the purpose decides the location of fault with respect to the relay in a distribution system. Such a strategy reduces the cost of voltage sensor and/or connection for a protection scheme which is of relevance in emerging distributed generation (DG) systems. The algorithm has been tested through simulation for different radial distribution systems.

[1]  Daqing Hou,et al.  Out-of-step protection fundamentals and advancements , 2004, 57th Annual Conference for Protective Relay Engineers, 2004.

[2]  G. W. Swift,et al.  A new directional element for numerical distance relays , 1995 .

[3]  Gerard Ledwich,et al.  Impact of Distributed Generation on Protection of Single Wire Earth Return Lines , 2002 .

[4]  P. B. Eriksen,et al.  System operation with high wind penetration , 2005, IEEE Power and Energy Magazine.

[5]  Adly Girgis,et al.  Optimal Estimation Of Voltage Phasors And Frequency Deviation Using Linear And Non-Linear Kalman Filtering: Theory And Limitations , 1984, IEEE Transactions on Power Apparatus and Systems.

[6]  S. I. Jang,et al.  An adaptive relaying for the protection of a wind farm interconnected with distribution networks , 2003, 2003 IEEE PES Transmission and Distribution Conference and Exposition (IEEE Cat. No.03CH37495).

[7]  M.M. Eissa Evaluation of a new current Directional Protection technique using field data , 2005, IEEE Transactions on Power Delivery.

[8]  James S. Thorp,et al.  Computer Relaying for Power Systems , 2009 .

[9]  M. S. Sachdev,et al.  Design, implementation and testing of an artificial neural network based fault direction discriminator for protecting transmission lines , 1995 .

[10]  Zhiqian Bo,et al.  Transient based protection for power transmission systems , 2000, 2000 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.00CH37077).

[11]  J.C. Gomez,et al.  Coordination of voltage sag and overcurrent protection in DG systems , 2005, IEEE Transactions on Power Delivery.

[12]  E. O. Schweitzer,et al.  Negative-sequence overcurrent element application and coordination in distribution protection , 1993 .

[13]  Walter Elmore,et al.  Protective Relaying Theory And Applications , 1994 .

[14]  Om P. Malik,et al.  A new digital directional transverse differential current protection technique , 1996 .