Is Post-Dialysis Urea Rebound Significant with Long Slow Hemodialysis?

Background: According to previous studies, postdialysis urea rebound (PDUR) is achieved within 30–90 min, leading to an overestimation of Kt/V of between 15 and 40% in 3- to 5-hour dialysis. The purpose of the study was to assess the impact of PDUR on the urea reduction ratio (URR), Kt/V and normal protein catabolic rate (nPCR) with long 8-hour slow hemodialysis. Methods: This study was performed in 18 patients (13 males/5 females), 62.5 ± 11.7 years of age, hemodialyzed for 3–265 months. Initial nephropathies were: 3 diabetes; 2 polycystic kidney disease; 3 interstitial nephritis; 2 nephrosclerosis; 3 chronic glomerulonephritis, and 5 undetermined. Residual renal function was negligible. The dialysis sessions were performed using 1- to 1.8-m2 cellulosic dialyzers during 8 h, 3 times a week. Blood flow was 220 ml/min, dialysate flow 500 ml/min, acetate or bicarbonate buffer was used. Serial measurements of the urea concentration were obtained before dialysis, immediately after dialysis (low flow at t = 0), and at 5, 10, 20, 30, 40, 60, 90 and 120 min, and before the next session. The low-flow method was used to evaluate the access recirculation, second-generation Daugirdas formulas for Kt/V, and Watson formulas for total body water volume estimation. The difference between the expected urea generation (UG) and urea measured after dialysis (global PDUR) defines net PDUR (n-PDUR). Results: The n-PDUR usually became stable after 58 ± 25 (30–90) min. Its mean value was 17 ± 10% of the 30-second low-flow postdialysis urea (3.9 ± 2 mmol/l). This small postdialysis urea value and the importance of UG in comparison with shorter dialysis justify the use of n-PDUR. Ignoring n-PDUR would lead to a significant 4% overestimation (p < 0.001) of the URR (79 ± 7 vs. 76 ± 8%), 12% of Kt/V (1.9 ± 0.4 to 1.7 ± 0.38) and 4% of the nPCR (1.1 ± 0.3 to 1.05 ± 0.3). n-PDUR correlated negatively with postdialysis urea (r = 0.45 p = 0.05), positively with URR (r = 0.31 p = 0.01) and Kt/V (r = 0.3 p = 0.03) but not with K, and negatively with the urea distribution volume (r = 0.33 p = 0.05). Mean total recirculation, ultrafiltration rate, predialysis urea levels and urea clearance did not correlate with n-PDUR. Conclusion: We found a significant PDUR in long-slow hemodialysis after a mean of 1 h after dialysis. This PDUR has a less important impact upon dialysis delivery estimation than short 3- to 5-hour hemodialysis, especially for the lower Kt/V or URR ranges. This is explained by the low-flux, high-efficiency, and long-term dialysis. Its inter-individual variability incites us to calculate PDUR on an individual basis.

[1]  Moncrief Jw,et al.  The consequences of physiological resistances on metabolite removal from the patient-artifical kidney system. , 1975 .

[2]  F. Gotch,et al.  Nitrogen balance during intermittent dialysis therapy of uremia. , 1978, Kidney international.

[3]  J T Daugirdas,et al.  Screening for extreme postdialysis urea rebound using the Smye method: patients with access recirculation identified when a slow flow method is not used to draw the postdialysis blood. , 1996, American journal of kidney diseases : the official journal of the National Kidney Foundation.

[4]  T. Depner Refining the Model of Urea Kinetics: Compartment Effects , 1992 .

[5]  Urea rebound and residual renal function in the calculation of Kt/V and protein catabolic rate. , 1993, Kidney international. Supplement.

[6]  P. Lönnroth,et al.  Urea kinetics during hemodialysis measured by microdialysis--a novel technique. , 1993, Kidney international.

[7]  T. Haas,et al.  Plasma kinetics of small molecules during and after hemofiltration: decrease in hemofiltration efficiency related to increase in ultrafiltration rate. , 1983, Clinical nephrology.

[8]  L. Pedrini,et al.  Causes, kinetics and clinical implications of post-hemodialysis urea rebound. , 1988, Kidney international.

[9]  T. Depner,et al.  Assessing adequacy of hemodialysis: urea modeling. , 1994, Kidney international.

[10]  R Charbonneau,et al.  Postdialysis urea rebound: determinants and influence on dialysis delivery in chronic hemodialysis patients. , 1996, American journal of kidney diseases : the official journal of the National Kidney Foundation.

[11]  F. Sigüenza,et al.  Analysis of urea distribution volume in hemodialysis. , 1994, Nephron.

[12]  R. Huisman,et al.  Determination of protein catabolic rate in patients on chronic intermittent hemodialysis: urea output measurements compared with dietary protein intake and with calculation of urea generation rate. , 1995, American journal of kidney diseases : the official journal of the National Kidney Foundation.

[13]  J T Daugirdas,et al.  A regional blood circulation alternative to in-series two compartment urea kinetic modeling. , 1993, ASAIO journal.

[14]  P. Kerr,et al.  Accuracy of Kt/V estimations in high-flux haemodiafiltration using per cent reduction of urea: incorporation of urea rebound. , 1993, Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association.

[15]  J T Daugirdas,et al.  Overestimation of hemodialysis dose depends on dialysis efficiency by regional blood flow but not by conventional two pool urea kinetic analysis. , 1995, ASAIO journal.

[16]  D. Spiegel,et al.  Hemodialysis urea rebound: the effect of increasing dialysis efficiency. , 1995, American journal of kidney diseases : the official journal of the National Kidney Foundation.

[17]  S W Smye,et al.  Estimation of treatment dose in high-efficiency haemodialysis. , 1994, Nephron.

[18]  A. Molino,et al.  Accuracy of an on-line urea monitor compared with urea kinetic model and direct dialysis quantification. , 1994, ASAIO journal.

[19]  J. Daugirdas,et al.  Estimating equilibrated Kt/V from an intradialytic sample: effects of access and cardiopulmonary recirculations. , 1995, Kidney international.

[20]  R. Toto,et al.  Accuracy of urea removal estimated by kinetic models. , 1995, Kidney international.