Implementation of Space Vector Based Hysteresis Current Control for a Three-Phase High Power Factor Converter
暂无分享,去创建一个
In this paper, an implementation of a space vector modulation (SVM) based hysteresis current controller (HCC) for the control of a three-phase high power factor rectifier is proposed. The SVM-based HCC scheme is designed, simulated and implemented. The technique combines the best features of the SVM and HCC techniques. The controller determines a set of state space vectors from a region detector and then applies a space vector selected according to HCC. A set of space vectors in a region, including the zero space vector for a reduced number of switchings, is determined from the output signals of three comparators with a hysteresis band a little larger than that of the main HCC. A simple experimental implementation is proposed and the simulation and experimental results of the SVM-based HCC are discussed in the paper.
[1] Boon Teck Ooi,et al. A Three-Phase Controlled-Current PWM Converter with Leading Power Factor , 1987, IEEE Transactions on Industry Applications.
[2] Jang-Hyoun Youm,et al. SVM-based hysteresis current controller for three-phase PWM rectifier , 1999 .
[3] R. Wu,et al. A PWM AC to DC converter with fixed switching frequency , 1988, Conference Record of the 1988 IEEE Industry Applications Society Annual Meeting.