Continuous Event-Based Harmonic Impedance Assessment Using Online Measurements

The quantification of harmonic emission requires an accurate model of the network harmonic impedances. A number of techniques have been proposed for the assessment of the network harmonic impedances to be practical and noninvasive. This paper presents an innovative application of the known assessment techniques based on pre and posttriggered waveform capturing of a rapid voltage change event. The harmonic impedance values are derived for each rapid voltage change event, analyzed, and the statistical median of the results is used to represent the network harmonic impedances. It enables an online and noninvasive tracking of network configuration and validation of simulated results.

[1]  B. Blazic,et al.  Harmonic Contributions Evaluation With the Harmonic Current Vector Method , 2008, IEEE Transactions on Power Delivery.

[2]  Hossein Mokhtari,et al.  Technique for online tracking of a utility harmonic impedance using by synchronising the measured samples , 2016 .

[3]  A. Ferrero,et al.  High accuracy Fourier analysis based on synchronous sampling techniques , 1992, [1992] Conference Record IEEE Instrumentation and Measurement Technology Conference.

[4]  Wilsun Xu,et al.  Online tracking of power system impedance parameters and field experiences , 2010, IEEE PES General Meeting.

[5]  Alessandro Ferrero,et al.  Harmonic power flow analysis for the measurement of the electric power quality , 1995 .

[6]  P. Schegner,et al.  Influence of instrument transformers on harmonic distortion assessment , 2012, 2012 IEEE Power and Energy Society General Meeting.

[7]  W. Xu,et al.  Harmonic impedance measurement using three-phase transients , 1998 .

[8]  Paulo F. Ribeiro,et al.  Guide for assessing the network harmonic impedance , 1997 .

[9]  Mulukutla S. Sarma,et al.  Power System Analysis and Design , 1993 .

[10]  Herwig Renner,et al.  Review of disturbance emissions assessment techniques , 2011 .

[11]  D.W.P. Thomas,et al.  Impedance measurement for improved power quality-Part 1: the measurement technique , 2004, IEEE Transactions on Power Delivery.

[12]  Johan Rens,et al.  Continuous harmonic impedance assessment using online measurements , 2015, 2015 IEEE International Workshop on Applied Measurements for Power Systems (AMPS).

[13]  Yilu Liu,et al.  A method for determining customer and utility harmonic contributions at the point of common coupling , 2000 .

[14]  Carlo Muscas Power quality monitoring in modern electric distribution systems , 2010, IEEE Instrumentation & Measurement Magazine.

[15]  W. Xu,et al.  Measurement of Network Harmonic Impedences: Practical Implementation Issues and Their Solutions , 2001, IEEE Power Engineering Review.

[16]  P. Schegner,et al.  Frequency Responses of MV voltage transformers in the range of 50 Hz to 10 kHz , 2010, Proceedings of 14th International Conference on Harmonics and Quality of Power - ICHQP 2010.

[17]  Wilsun Xu,et al.  Determination of network harmonic impedances using steady-state measurements , 1999, 1999 IEEE Power Engineering Society Summer Meeting. Conference Proceedings (Cat. No.99CH36364).

[18]  Seyed Hossein Hosseinian,et al.  A Novel Method for Noninvasive Estimation of Utility Harmonic Impedance Based on Complex Independent Component Analysis , 2015, IEEE Transactions on Power Delivery.

[19]  T. Ohnstad,et al.  Voltage transformer frequency response. Measuring harmonics in Norwegian 300 kV and 132 kV power systems , 1998, 8th International Conference on Harmonics and Quality of Power. Proceedings (Cat. No.98EX227).

[20]  Edith Clarke,et al.  Circuit analysis of A-C power systems , 1950 .

[21]  Johan Rens,et al.  The effect of real network phase disturbances on the calculation of IEC 61000-4-30 parameters , 2014, 2014 16th International Conference on Harmonics and Quality of Power (ICHQP).