Challenges Associated with Effective Implementation of CT Dose Check Standards and Radiation Monitoring Index in Computed Tomography: Healthcare Sector Experience
暂无分享,去创建一个
E. Dalah | Yousuf Mohammad Al Al Musfari | Badriya Mohd Hassan Ali | Anwaar Abdulrahim Al Al Hammadi | Hashim Abdul Azeez Beevi | Manal Ibrahim Jaber | Alyazya Akeel Al-Ali | Ayesha Khalid Alkharoossi | Fairooz Hussain Al Hashemi | Fatma Mahmood Alkhatib | Sabaa Anam Aqil Khan
[1] Entesar Zawam Dalah,et al. Challenges Experienced in Establishing Clinical Indication Based Diagnostic Reference Levels: Pilot Study , 2021, European Journal of Radiology.
[2] M. McNitt-Gray,et al. AAPM Medical Physics Practice Guideline 1.b: CT protocol management and review practice guideline , 2021, Journal of applied clinical medical physics.
[3] S. Schindera,et al. Radiation dose management systems—requirements and recommendations for users from the ESR EuroSafe Imaging initiative , 2020, European Radiology.
[4] M. McEntee,et al. Radiation dose tracking in computed tomography: Red alerts and feedback. Implementing a radiation dose alert system in CT. , 2020, Radiography.
[5] N. D. Osman,et al. Radiation dose management in CT imaging: Initial experience with commercial dose watch software , 2020, Journal of Physics: Conference Series.
[6] M. Arreola,et al. Impact of patient centering in CT on organ dose and the effect of using a positioning compensation system: Evidence from OSLD measurements in postmortem subjects , 2019, Journal of applied clinical medical physics.
[7] Robert K. Bour,et al. The Current State of CT Dose Management Across Radiology: Well Intentioned but Not Universally Well Executed. , 2018, AJR. American journal of roentgenology.
[8] C J Martin,et al. ICRP Publication 135: Diagnostic Reference Levels in Medical Imaging , 2017, Annals of the ICRP.
[9] S. Schindera,et al. Transatlantic Comparison of CT Radiation Doses in the Era of Radiation Dose-Tracking Software. , 2017, AJR. American journal of roentgenology.
[10] William D. Erwin,et al. AAPM medical physics practice guideline 6.a.: Performance characteristics of radiation dose index monitoring systems , 2017, Journal of applied clinical medical physics.
[11] R. Marsh,et al. The effects of patient positioning when interpreting CT dose metrics: A phantom study , 2017, Medical physics.
[12] M. Mahesh. What Is the CT Dose Check Standard, and Why Do CT Scanners Need to Be in Compliance? , 2016, Journal of the American College of Radiology.
[13] María del Rosario,et al. The World Health Organization Global Initiative on Radiation Safety in Healthcare Settings , 2015 .
[14] Donald L. Miller,et al. Clinical implementation of the National Electrical Manufacturers Association CT Dose Check standard at ACR Dose Index Registry sites. , 2014, Journal of the American College of Radiology : JACR.
[15] C. McCollough,et al. Use of CT dose notification and alert values in routine clinical practice. , 2014, Journal of the American College of Radiology : JACR.
[16] Alice R. Goldman,et al. Reducing radiation dose in body CT: a primer on dose metrics and key CT technical parameters. , 2013, AJR. American journal of roentgenology.
[17] J. Boone,et al. Size-Specific Dose Estimates (SSDE) in Pediatric and Adult Body CT Examinations , 2011 .