Impedance Modeling and Stability Analysis of DFIG-Based Wind Energy Conversion System Considering Frequency Coupling

Impedance-based stability analysis is an effective method for addressing a new type of SSO accidents that have occurred in recent years, especially those caused by the control interaction between a DFIG and the power grid. However, the existing impedance modeling of DFIGs is mostly focused on a single converter, such as the GSC or RSC, and the influence between the RSC and GSC, as well as the frequency coupling effect inside the converter are usually overlooked, reducing the accuracy of DFIG stability analysis. Hence, the entire impedance is proposed in this paper for the DFIG-based WECS, taking coupling factors into account (e.g., DC bus voltage dynamics, asymmetric current regulation in the dq frame, and PLL). Numerical calculations and HIL simulations on RT-Lab were used to validate the proposed model. The results indicate that the entire impedance model with frequency coupling is more accurate, and it is capable of accurately predicting the system’s possible resonance points.

[2]  Guangfu Tang,et al.  Harmonic Stability Analysis of MMC-Based DC System Using DC Impedance Model , 2020, IEEE Journal of Emerging and Selected Topics in Power Electronics.

[3]  Hans-Peter Nee,et al.  A Comparison of Different Frequency Scanning Methods for Study of Subsynchronous Resonance , 2011, IEEE Transactions on Power Systems.

[4]  Mohamed Abdeen,et al.  Output impedance modeling and grid-connected stability study of virtual synchronous control-based doubly-fed induction generator wind turbines in weak grids , 2021 .

[5]  Xiaorong Xie,et al.  Overview of emerging subsynchronous oscillations in practical wind power systems , 2019, Renewable and Sustainable Energy Reviews.

[6]  Zhixin Miao,et al.  Impedance-Model-Based SSR Analysis for Type 3 Wind Generator and Series-Compensated Network , 2012, IEEE Transactions on Energy Conversion.

[7]  Xiaorong Xie,et al.  Hardware-in-the-Loop and Field Validation of a Rotor-Side Subsynchronous Damping Controller for a Series Compensated DFIG System , 2021, IEEE Transactions on Power Delivery.

[8]  Bo Wen,et al.  Analysis of D-Q Small-Signal Impedance of Grid-Tied Inverters , 2016, IEEE Transactions on Power Electronics.

[9]  Heng Nian,et al.  Frequency Coupling Characteristic Modeling and Stability Analysis of Doubly Fed Induction Generator , 2018, IEEE Transactions on Energy Conversion.

[10]  Peter W. Lehn,et al.  Using Frequency Coupling Matrix Techniques for the Analysis of Harmonic Interactions , 2016, IEEE Transactions on Power Delivery.

[11]  A. Phadke,et al.  Stability Assessment of DFIG Subsynchronous Oscillation Based on Energy Dissipation Intensity Analysis , 2020, IEEE Transactions on Power Electronics.

[12]  Bo Wen,et al.  Impedance-Based Analysis of Grid-Synchronization Stability for Three-Phase Paralleled Converters , 2014, IEEE Transactions on Power Electronics.

[13]  Liang Wang,et al.  Investigation of SSR in Practical DFIG-Based Wind Farms Connected to a Series-Compensated Power System , 2015, IEEE Transactions on Power Systems.

[14]  Kai Sun,et al.  Understanding Subsynchronous Oscillations in DFIG-Based Wind Farms Without Series Compensation , 2019, IEEE Access.

[15]  H. Nian,et al.  High-Frequency Resonance Analysis and Reshaping Control Strategy of DFIG System Based on DPC , 2021, IEEE Transactions on Power Electronics.

[16]  Leila Parsa,et al.  Impedance Modeling of Three-Phase Voltage Source Converters in DQ, Sequence, and Phasor Domains , 2017, IEEE Transactions on Energy Conversion.

[17]  Liang Chen,et al.  Sequences Domain Impedance Modeling of Three-Phase Grid-Connected Converter Using Harmonic Transfer Matrices , 2018, IEEE Transactions on Energy Conversion.

[18]  Dianguo Xu,et al.  Impedance Modeling and SSR Analysis of DFIG Using Complex Vector Theory , 2019, IEEE Access.

[19]  Jian Sun,et al.  Development and Application of Type-III Turbine Impedance Models Including DC Bus Dynamics , 2020, IEEE Open Journal of Power Electronics.

[20]  Xiaorong Xie,et al.  Wide-area monitoring and early-warning of subsynchronous oscillation in power systems with high-penetration of renewables , 2019, International Journal of Electrical Power & Energy Systems.

[21]  Xiqiang Chang,et al.  Identifying the Source of Subsynchronous Control Interaction via Wide-Area Monitoring of Sub/Super-Synchronous Power Flows , 2020, IEEE Transactions on Power Delivery.

[22]  Jinyu Wen,et al.  Impedance Modeling and Stability Analysis of Grid-Connected DFIG-Based Wind Farm With a VSC-HVDC , 2020, IEEE Journal of Emerging and Selected Topics in Power Electronics.

[23]  Jian Sun,et al.  Sequence Impedance Modeling and Analysis of MMC in Single-Star Configuration , 2020, IEEE Transactions on Power Electronics.

[24]  Yang Wang,et al.  Impedance Network Model Based Modal Observability and Controllability Analysis for Renewable Integrated Power Systems , 2021, IEEE Transactions on Power Delivery.

[25]  Malsha S. Annakkage,et al.  Frequency Scan-Based Screening Method for Device Dependent Sub-Synchronous Oscillations , 2016, IEEE Transactions on Power Systems.

[26]  Sung-Yul Kim,et al.  Subsynchronous Oscillation and Advanced Analysis: A Review , 2020, IEEE Access.

[27]  Xiaorong Xie,et al.  Comparative Studies on the Impedance Models of VSC-Based Renewable Generators for SSI Stability Analysis , 2019, IEEE Transactions on Energy Conversion.

[28]  Aurelio Medina-Rios,et al.  A Time-Domain Companion-Circuit Newton-Based Methodology Applied to the Harmonic Analysis of Electrical Networks With PV Systems , 2020, IEEE Access.