CPR quality improvement during in-hospital cardiac arrest using a real-time audiovisual feedback system.

BACKGROUND Cardiopulmonary resuscitation (CPR) quality during actual cardiac arrest has been found to be deficient in several recent investigations. We hypothesized that real-time feedback during CPR would improve the performance of chest compressions and ventilations during in-hospital cardiac arrest. METHODS An investigational monitor/defibrillator with CPR-sensing and feedback capabilities was used during in-hospital cardiac arrests from December 2004 to December 2005. Chest compression and ventilation characteristics were recorded and quantified for the first 5 min of resuscitation and compared to a baseline cohort of arrest episodes without feedback, from December 2002 to April 2004. RESULTS Data from 55 resuscitation episodes in the baseline pre-intervention group were compared to 101 resuscitations in the feedback intervention group. There was a trend toward improvement in the mean values of CPR variables in the feedback group with a statistically significant narrowing of CPR variable distributions including chest compression rate (104+/-18 to 100+/-13 min(-1); test of means, p=0.16; test of variance, p=0.003) and ventilation rate (20+/-10 to 18+/-8 min(-1); test of means, p=0.12; test of variance, p=0.04). There were no statistically significant differences between the groups in either return of spontaneous circulation or survival to hospital discharge. CONCLUSIONS Real-time CPR-sensing and feedback technology modestly improved the quality of CPR during in-hospital cardiac arrest, and may serve as a useful adjunct for rescuers during resuscitation efforts. However, feedback specifics should be optimized for maximal benefit and additional studies will be required to assess whether gains in CPR quality translate to improvements in survival.

[1]  H. Halperin,et al.  Improved hemodynamic performance with a novel chest compression device during treatment of in-hospital cardiac arrest. , 2004, Resuscitation.

[2]  Stig Steen,et al.  Treatment of out-of-hospital cardiac arrest with LUCAS, a new device for automatic mechanical compression and active decompression resuscitation. , 2005, Resuscitation.

[3]  M. Copass,et al.  Influence of cardiopulmonary resuscitation prior to defibrillation in patients with out-of-hospital ventricular fibrillation , 1999, JAMA.

[4]  P. Steen,et al.  Quality of cardiopulmonary resuscitation during out-of-hospital cardiac arrest. , 2005, JAMA.

[5]  P. Steen,et al.  An automated voice advisory manikin system for training in basic life support without an instructor. A novel approach to CPR training. , 2001, Resuscitation.

[6]  T. Hodgetts,et al.  Incidence, location and reasons for avoidable in-hospital cardiac arrest in a district general hospital. , 2002, Resuscitation.

[7]  M. Eisenberg,et al.  Primary care : Cardiac resuscitation , 2001 .

[8]  Jo Kramer-Johansen,et al.  Quality of out-of-hospital cardiopulmonary resuscitation with real time automated feedback: a prospective interventional study. , 2006, Resuscitation.

[9]  J. Ornato,et al.  Cardiopulmonary resuscitation of adults in the hospital: a report of 14720 cardiac arrests from the National Registry of Cardiopulmonary Resuscitation. , 2003, Resuscitation.

[10]  Subcommittees 2005 American Heart Association Guidelines for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care. , 2005 .

[11]  J. Ornato,et al.  Use of an automated, load-distributing band chest compression device for out-of-hospital cardiac arrest resuscitation. , 2006, JAMA.

[12]  B. Abella,et al.  Chest Compression Rates During Cardiopulmonary Resuscitation Are Suboptimal: A Prospective Study During In-Hospital Cardiac Arrest , 2005, Circulation.

[13]  Kim Connelly,et al.  Improvement in timing and effectiveness of external cardiac compressions with a new non-invasive device: the CPR-Ezy. , 2002, Resuscitation.

[14]  P. Steen,et al.  Delaying defibrillation to give basic cardiopulmonary resuscitation to patients with out-of-hospital ventricular fibrillation: a randomized trial. , 2003, JAMA.

[15]  Abraham Noordergraaf,et al.  The quality of chest compressions by trained personnel: the effect of feedback, via the CPREzy, in a randomized controlled trial using a manikin model. , 2006, Resuscitation.

[16]  Jo Kramer-Johansen,et al.  Effects of compression depth and pre-shock pauses predict defibrillation failure during cardiac arrest. , 2006, Resuscitation.

[17]  T. Rea,et al.  Manual chest compression vs use of an automated chest compression device during resuscitation following out-of-hospital cardiac arrest: a randomized trial. , 2006, JAMA.

[18]  Matthew Huei-Ming Ma,et al.  Better adherence to the guidelines during cardiopulmonary resuscitation through the provision of audio-prompts. , 2005, Resuscitation.

[19]  Jo Kramer-Johansen,et al.  Quality of cardiopulmonary resuscitation during out-of-hospital cardiac arrest , 2005 .

[20]  Sven Ole Aase,et al.  Compression depth estimation for CPR quality assessment using DSP on accelerometer signals , 2002, IEEE Transactions on Biomedical Engineering.

[21]  Robert A. Berg,et al.  Interruptions of Chest Compressions During Emergency Medical Systems Resuscitation , 2005, Circulation.

[22]  E. John Gallagher,et al.  Effectiveness of Bystander Cardiopulmonary Resuscitation and Survival Following Out-of-Hospital Cardiac Arrest , 1995 .

[23]  P. Steen,et al.  Effects of Interrupting Precordial Compressions on the Calculated Probability of Defibrillation Success During Out-of-Hospital Cardiac Arrest , 2002 .

[24]  Tom P. Aufderheide,et al.  Hyperventilation-Induced Hypotension During Cardiopulmonary Resuscitation , 2004, Circulation.

[25]  S. Handley,et al.  Improving CPR performance using an audible feedback system suitable for incorporation into an automated external defibrillator. , 2003, Resuscitation.

[26]  P. Larsen,et al.  Effect of automatic external defibrillator audio prompts on cardiopulmonary resuscitation performance , 2005, Emergency Medicine Journal.