Automatic optimal input command for linearization of cMUT output by a temporal target

Capacitive micromachined ultrasonic transducers (cMUTs) are a promising alternative to the piezoelectric transducer. However, their native nonlinear behavior is a limitation for their use in medical ultrasound applications. Several methods based on the pre-compensation of a preselected input voltage have been proposed to cancel out the harmonic components generated. Unfortunately, these existing pre-compensation methods have two major flaws. The first is that the pre-compensation procedure is not generally automatic, and the second is that they can only reduce the second harmonic component. This can, therefore, limit their use for some imaging methods, which require a broader bandwidth, e.g., to receive the third harmonic component. In this study, we generalized the presetting methods to reduce all nonlinearities in the cMUT output. Our automatic pre-compensation method can work whatever the excitation waveform. The precompensation method is based on the nonlinear modeling of harmonic components from a Volterra decomposition in which the parameters are evaluated by using a Nelder-Mead algorithm. To validate the feasibility of this approach, the method was applied to an element of a linear array with several types of excitation often encountered in encoded ultrasound imaging. The results showed that the nonlinear components were reduced by up to 21.2 dB.

[1]  A. Bouakaz,et al.  Harmonic chirp imaging method for ultrasound contrast agent , 2005, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[2]  J. Seeger,et al.  Stabilization of electrostatically actuated mechanical devices , 1997, Proceedings of International Solid State Sensors and Actuators Conference (Transducers '97).

[3]  Russell R. Barton,et al.  On convergence of the nelder-mead simplex algorithm for unconstrained stochastic optimization , 1995 .

[4]  Jeffrey C. Lagarias,et al.  Convergence Properties of the Nelder-Mead Simplex Method in Low Dimensions , 1998, SIAM J. Optim..

[5]  Robert R. Bitmead,et al.  Adaptive Control Algorithms , 1991 .

[6]  S. Zhou,et al.  Precompensated excitation waveforms to suppress harmonic generation in MEMS electrostatic transducers , 2003, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[7]  S. Senturia Microsystem Design , 2000 .

[8]  P. Burns,et al.  Instrumentation for Contrast Echocardiography , 2002, Echocardiography.

[9]  H. Koymen,et al.  Nonlinear modeling of an immersed transmitting capacitive micromachined ultrasonic transducer for harmonic balance analysis , 2010, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[10]  V. J. Mathews,et al.  Polynomial Signal Processing , 2000 .

[11]  F. T. ten Cate,et al.  Super harmonic imaging: a new imaging technique for improved contrast detection. , 2002, Ultrasound in medicine & biology.

[12]  Rogelio Lozano,et al.  Adaptive Control: Algorithms, Analysis and Applications , 2011 .

[13]  B.T. Khuri-Yakub,et al.  Calculation and measurement of electromechanical coupling coefficient of capacitive micromachined ultrasonic transducers , 2003, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[14]  Daniel J. Woods,et al.  Optimization on Microcomputers: The Nelder-Mead Simplex Algorithm , 1985 .

[15]  A. E. Miller,et al.  A NEW METHOD FOR THE GENERATION AND USE OF FOCUSED ULTRASOUND IN EXPERIMENTAL BIOLOGY , 1942, The Journal of general physiology.

[16]  Characterization of transducer arrays by laser interferometry: influence of acousto-optic interactions on displacement measurements in water , 2001, 2001 IEEE Ultrasonics Symposium. Proceedings. An International Symposium (Cat. No.01CH37263).

[17]  Ayache Bouakaz,et al.  Second harmonic and subharmonic for non-linear wideband contrast imaging using a capacitive micromachined ultrasonic transducer array. , 2013, Ultrasound in medicine & biology.

[18]  Walter A. Frank An efficient approximation to the quadratic Volterra filter and its application in real-time loudspeaker linearization , 1995, Signal Process..

[19]  F. Teston,et al.  Fast time-domain modeling of fluid-coupled cMUT cells: from the single cell to the 1-D linear array element , 2013, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[20]  P.-C. Eccardt,et al.  Linear and nonlinear equivalent circuit modeling of CMUTs , 2005, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[21]  D. Royer,et al.  Quantitative imaging of transient acoustic fields by optical heterodyne interferometry , 1994, 1994 Proceedings of IEEE Ultrasonics Symposium.

[22]  B. Khuri-Yakub,et al.  A surface micromachined electrostatic ultrasonic air transducer , 1996, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[23]  O. Oralkan,et al.  Capacitive micromachined ultrasonic transducers: fabrication technology , 2005, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[24]  Sébastien Ménigot,et al.  Optimization of Contrast-to-Tissue Ratio by Adaptation of Transmitted Ternary Signal in Ultrasound Pulse Inversion Imaging , 2013, Comput. Math. Methods Medicine.

[25]  Mario Kupnik,et al.  Capacitive Micromachined Ultrasonic Transducers for Therapeutic Ultrasound Applications , 2010, IEEE Transactions on Biomedical Engineering.

[26]  Antonio Iula,et al.  Design, fabrication and characterization of a capacitive micromachined ultrasonic probe for medical imaging , 2005, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[27]  Omer Oralkan,et al.  Capacitive micromachined ultrasonic transducers for medical imaging and therapy , 2011, Journal of micromechanics and microengineering : structures, devices, and systems.

[28]  P. Burns,et al.  Pulse inversion Doppler: a new method for detecting nonlinear echoes from microbubble contrast agents , 1997, 1997 IEEE Ultrasonics Symposium Proceedings. An International Symposium (Cat. No.97CH36118).

[29]  John A. Nelder,et al.  A Simplex Method for Function Minimization , 1965, Comput. J..

[30]  F. L. Degertekin,et al.  Harmonic reduction in capacitive micromachined ultrasonic transducers by gap feedback linearization , 2012, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[31]  Shiwei Zhou,et al.  Reducing inter-element acoustic crosstalk in capacitive micromachined ultrasound transducers , 2007, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[32]  A. Bouakaz,et al.  Exploitation of capacitive micromachined transducers for nonlinear ultrasound imaging , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[33]  J. Wilhjelm Bandwidth expressions of Gaussian weighted chirp , 1993 .