Lithium Ion-selective Electrodes Employing Tetrahydrofuran-based 16-Crown-4 Derivatives as Neutral Carriers
暂无分享,去创建一个
Y. Kang | Kyoung Moon Lee | H. Nam | G. Cha | S. Jung | Jae Sang Kim
[1] George F. Wright,et al. THE CONDENSATION OF METHYL KETONES WITH FURAN , 1955 .
[2] M. Asada,et al. Macrocyclic ligands composed of tetrahydrofuran for selective transport of monovalent cations through liquid membranes , 1976 .
[3] D. Tosteson. Lithium and mania. , 1981, Scientific American.
[4] A. F. Zhukov,et al. Lipophilic Diamides as Ionophores for Alkali and Alkaline Earth Metal Cations , 1982 .
[5] G. Christian,et al. Determination of selectivity coefficients of ion-selective electrodes by a matched-potential method , 1984 .
[6] B. Kräutler,et al. A Lipophilic Derivative of Vitamin B12 as Selective Carrier for Anions , 1984 .
[7] R. Ng,et al. The Technicon RA-1000 evaluated for measuring sodium, potassium, chloride, and carbon dioxide. , 1985, Clinical chemistry.
[8] M. Egli,et al. 3,7-Dioxaazelaamides as Ionophores for Lithium Ion Selective Liquid Membrane Electrodes , 1986 .
[9] W. Simon,et al. Ion-selective membrane electrodes for clinical use. , 1986, Clinical chemistry.
[10] W. Simon,et al. Ion selective liquid membrane electrode for the assay of lithium in blood serum. , 1986, Analytical chemistry.
[11] W. Simon,et al. Lithium/sodium ion concentration ratio measurements in blood serum with lithium and sodium ion selective liquid membrane electrodes. , 1987, Analytical chemistry.
[12] K. Kimura,et al. Lithium ion selective electrodes based on crown ethers for serum lithium assay. , 1987, Analytical chemistry.
[13] G. Christian,et al. Comparative evaluation of neutral, and proton-ionizable crown ether compounds as lithium ionophores in ion-selective electrodes and in solvent extraction , 1988 .
[14] W. Simon,et al. Elimination of the asymmetry in neutral-carrier-based solvent polymeric membranes induced by proteins. , 1988, Analytical chemistry.
[15] M. Meyerhoff. New in vitro analytical approaches for clinical chemistry measurements in critical care. , 1990, Clinical chemistry.
[16] K. Tohda,et al. Design and synthesis of lithium ionophores for an ion-selective electrode by chemical modification of natural carboxylic polyether antibiotic monensin , 1990 .
[17] W. E. Morf,et al. Selectivity-modifying influence of anionic sites in neutral-carrier-based membrane electrodes , 1991 .
[18] R. Kataky,et al. Comparative performance of 14-crown-4 derivatives as lithium-selective electrodes. , 1991, The Analyst.
[19] Yu Liu,et al. Molecular design of crown ethers. 12. Complexation thermodynamics of 12- to 16-crown-4: thermodynamic origin of high lithium selectivity of 14-crown-4 , 1993 .
[20] Koji Suzuki,et al. Design and synthesis of highly selective ionophores for lithium ion based on 14-crown-4 derivatives for an ion-selective electrode , 1993 .
[21] Lipophilic Crown-4 Derivatives as Lithium Ionophores for Lithium Ion Selective Liquid Membrane Electrodes , 1993 .
[22] Takayuki Inoue,et al. Amine-armed aza-12-crown-4 as a new Li+ ion-specific ionophore , 1993 .
[23] R. Yatscoff,et al. Evaluation of the i-STAT system: a portable chemistry analyzer for the measurement of sodium, potassium, chloride, urea, glucose, and hematocrit. , 1995, Clinical biochemistry.
[24] Evaluation of the ion selective electrodes module in the DAX analyzers , 1995 .
[25] Minimization of Asymmetry Potential in ETH 129-Based Calcium-Selective Membrane Electrodes , 1995 .
[26] T. Okada,et al. Role of plasticizers on the characteristics of poly(vinyl chloride)-membrane lithium-selective electrodes based on phenanthroline derivatives , 1995 .
[27] Lithium Ion-Selective Electrode Based on THF-Based 16-Crown-4 Derivatives , 1995 .
[28] Linearity and stability of the AVL and Nova magnesium and calcium ion-selective electrodes. , 1996, Clinical chemistry.