Macro to microfluidics system for biological environmental monitoring.

Biological environmental monitoring (BEM) is a growing field of research which challenges both microfluidics and system automation. The aim is to develop a transportable system with analysis throughput which satisfies the requirements: (i) fully autonomous, (ii) complete protocol integration from sample collection to final analysis, (iii) detection of diluted molecules or biological species in a large real life environmental sample volume, (iv) robustness and (v) flexibility and versatility. This paper discusses all these specifications in order to define an original fluidic architecture based on three connected modules, a sampling module, a sample preparation module and a detection module. The sample preparation module highly concentrates on the pathogens present in a few mL samples of complex and unknown solutions and purifies the pathogens' nucleic acids into a few μL of a controlled buffer. To do so, a two-step concentration protocol based on magnetic beads is automated in a reusable macro-to-micro fluidic system. The detection module is a PCR based miniaturized platform using digital microfluidics, where reactions are performed in 64 nL droplets handled by electrowetting on dielectric (EWOD) actuation. The design and manufacture of the two modules are reported as well as their respective performances. To demonstrate the integration of the complete protocol in the same system, first results of pathogen detection are shown.

[1]  Vijay Srinivasan,et al.  Development of a digital microfluidic platform for point of care testing. , 2008, Lab on a chip.

[2]  Y. Fouillet,et al.  Digital microfluidic design and optimization of classic and new fluidic functions for lab on a chip systems , 2008 .

[3]  R. Fair,et al.  An integrated digital microfluidic lab-on-a-chip for clinical diagnostics on human physiological fluids. , 2004, Lab on a chip.

[4]  G. Snow,et al.  Ultra-sonic nebulizers as a potential source of methicillin-resistant Staphylococcus aureus causing an outbreak in a university tertiary care hospital. , 2003, The Journal of hospital infection.

[5]  F Lesbre,et al.  A novel fluorescence-based array biosensor: principle and application to DNA hybridization assays. , 2008, Biosensors & bioelectronics.

[6]  J. Gehanno,et al.  Aerial dispersal of meticillin-resistant Staphylococcus aureus in hospital rooms by infected or colonised patients. , 2009, The Journal of hospital infection.

[7]  Phil Paik,et al.  Rapid droplet mixers for digital microfluidic systems. , 2003, Lab on a chip.

[8]  Benjamin J Hindson,et al.  Environmental monitoring for biological threat agents using the autonomous pathogen detection system with multiplexed polymerase chain reaction. , 2008, Analytical chemistry.

[9]  Jean Cumps,et al.  Improved real-time RT-PCR method for high-throughput measurements using second derivative calculation and double correction. , 2005, BioTechniques.

[10]  A. Berg,et al.  Micro Total Analysis Systems , 1995 .

[11]  Richard B. Fair,et al.  Digital microfluidics: is a true lab-on-a-chip possible? , 2007 .

[12]  S. Cho,et al.  Creating, transporting, cutting, and merging liquid droplets by electrowetting-based actuation for digital microfluidic circuits , 2003 .

[13]  Aaron R Wheeler,et al.  Electrowetting-based microfluidics for analysis of peptides and proteins by matrix-assisted laser desorption/ionization mass spectrometry. , 2004, Analytical chemistry.

[14]  R. Fair,et al.  Electrowetting-based actuation of droplets for integrated microfluidics. , 2002, Lab on a chip.

[15]  R. Gaynes,et al.  Nosocomial infection rates in adult and pediatric intensive care units in the United States. National Nosocomial Infections Surveillance System. , 1991, The American journal of medicine.

[16]  A. Fraise,et al.  An unusual source for an outbreak of methicillin-resistant Staphylococcus aureus on an intensive therapy unit. , 1996, The Journal of hospital infection.

[17]  Teodor Veres,et al.  Integration and detection of biochemical assays in digital microfluidic LOC devices. , 2010, Lab on a chip.

[18]  T. H. Rider,et al.  A B Cell-Based Sensor for Rapid Identification of Pathogens , 2003, Science.

[19]  Y. Fouillet,et al.  Rotating flow within a droplet actuated with AC EWOD , 2009 .