Retrofit scheme of FRP jacketing system for blast damage mitigation of non-ductile RC building frames

Abstract Non-ductile reinforced concrete building structures built before the 1970s have been significantly damaged and collapsed under man-made disasters (e.g., blast loads) due to their inadequate column details. The structural deficiencies can be mitigated by a fiber-reinforced polymer jacketing system. This research investigated the blast performance of a low-rise non-ductile building frame strengthened with the jacketing system. Based on the investigation, a retrofit scheme was established to mitigate the blast-induced damage and maximize the effectiveness of the retrofit system. The retrofitted models varied with the main parameters of the retrofit system associated with the confinement effect and flexural stiffness, and blast simulation was performed under various loading scenarios. The retrofit effect was examined in terms of confinement and stiffness ratios. Since the effects of the retrofit parameters on the blast performance depend on the blast loads, the retrofit scheme needs to be established in terms of expected blast loading scenarios.

[1]  Xiaoshan Lin,et al.  Modelling the response of reinforced concrete panels under blast loading , 2014 .

[2]  Robert Kunc,et al.  Minimum mesh design criteria for blast wave development and structural response - MMALE method , 2014 .

[3]  Todd P Slavik,et al.  A coupling of empirical explosive blast loads to ALE air domains in LS-DYNA® , 2010 .

[4]  Jian fei Chen,et al.  Blast resistance of FRP composites and polymer strengthened concrete and masonry structures - A state-of-the-art review , 2007 .

[5]  Marian Giżejowski,et al.  Example Validation of Numerical Modeling of Blast Loading , 2011 .

[6]  John E. Crawford,et al.  Retrofit of Reinforced Concrete Structures to Resist Blast Effects , 1997 .

[7]  Gilbert A. Hegemier,et al.  Analytical Model for Fiber-Reinforced Polymer-Jacketed Square Concrete Columns in Axial Compression , 2010 .

[8]  E CrawfordJohn,et al.  State of the art for enhancing the blast resistance of reinforced concrete columns with fiber-reinforced plastic1 , 2013 .

[9]  M. R. Spoelstra,et al.  FRP-Confined Concrete Model , 2001 .

[10]  Timothy R. Wright Full-scale seismic testing of a reinforced concrete moment frame using mobile shakers , 2015 .

[11]  Kenneth B. Morrill,et al.  Use of Composites to Resist Blast , 2007 .

[12]  David W. Scott,et al.  Implementation of Bond-Slip Performance Models in the Analyses of Non-Ductile Reinforced Concrete Frames Under Dynamic Loads , 2020 .

[13]  Bing Li,et al.  Residual Strength of Blast Damaged Reinforced Concrete Columns , 2010 .

[14]  Hong Hao,et al.  Bond slip modelling and its effect on numerical analysis of blast-induced responses of RC columns , 2009 .

[15]  A. Mirmiran,et al.  Effect of Column Parameters on FRP-Confined Concrete , 1998 .

[16]  A. Ang,et al.  Mechanistic Seismic Damage Model for Reinforced Concrete , 1985 .

[17]  Brahim Benmokrane,et al.  440.2R-02 Guide for the Design and Construction of Externally Bonded FRP Systems for Strengthening Concrete Structures , 2002 .

[18]  Sami H. Rizkalla,et al.  Confinement Model for Axially Loaded Concrete Confined by Circular Fiber-Reinforced Polymer Tubes , 2001 .

[19]  Jyh-Tong Teng,et al.  A Three-Dimensional Numerical Investigation into the Interaction of Blast Waves with Bomb Shelters , 2005 .

[20]  John B. Mander,et al.  Seismic Resistance of Reinforced Concrete Frame Structures Designed for Gravity Loads: Performance of Structural System , 1995 .

[21]  James T. Baylot,et al.  Effect of responding and failing structural components on the airblast pressures and loads on and inside of the structure , 2007 .

[22]  George Daniel Williams Analysis and response mechanisms of blast-loaded reinforced concrete columns , 2009 .

[23]  Reginald DesRoches,et al.  Dynamic response of a full-scale reinforced concrete building frame retrofitted with FRP column jackets , 2016 .

[24]  Mathias Fink,et al.  Eigenmodes of the time reversal operator: a solution to selective focusing in multiple-target media , 1994 .

[25]  Jiuk Shin Multi-hazard performance criteria for non-ductile reinforced concrete frame buildings retrofitted with an FRP column jacketing system , 2017 .

[26]  John E. Crawford,et al.  Numerical Modeling of Concrete Using a Partially Associative Plasticity Model , 2015 .

[27]  Hong Hao,et al.  Numerical derivation of pressure-impulse diagrams for prediction of RC column damage to blast loads , 2008 .

[28]  Stanley C. Woodson,et al.  Structural Collapse: Quarter-Scale Model Experiments , 1999 .

[29]  L. Muszynski,et al.  Composite Reinforcement to Strengthen Existing Concrete Structures against Air Blast , 2003 .

[30]  Richard Sause,et al.  Flexural Behavior of Concrete Columns Retrofitted with Carbon Fiber-Reinforced Polymer Jackets , 2004 .

[31]  Huabei Liu,et al.  Finite Element Simulation of Medium-Range Blast Loading Using LS-DYNA , 2015 .

[32]  J. Mander,et al.  Theoretical stress strain model for confined concrete , 1988 .

[33]  W. Gene Corley Lessons Learned on Improving Resistance of Buildings to Terrorist Attacks , 2004 .

[34]  Norman J. Glover The Oklahoma City Bombing: Improving Building Performance through Multi-Hazard Mitigation (FEMA 277) by Building Performance Analysis Team , 1997 .