Human convective boundary layer and its impact on personal exposure

(06/12/2018) Human convective boundary layer and its impact on personal exposure People spend most of their time indoors and they are constantly exposed to pollution that affects their health, comfort and productivity. Due to strong economic and environmental pressures to reduce building energy consumption, low air velocity design is gaining popularity; hence buoyancy flows generated by heat sources are gaining more prominent influence in space airflow formation and on the indoor environment overall. In such spaces with low air supply velocity, air mixing is minimized and the pollution emitted from localized indoor sources is non-uniformly distributed. The large spatial differences in pollution concentration mean that personal exposure, rather than average space concentration, determines the risk of elevated exposure. Current room air distribution design practice does not take into account the air movement induced by the thermal flows from occupants, which often results in inaccurate exposure prediction. This highlights the importance of a detailed understanding of the complex air movements that take place in the vicinity of the human body and their impact on personal exposure. The two objectives of the present work are: (i) to examine the extent to which the room air temperature, ventilation flow, body posture, clothing insulation/design, table positioning and chair design affect the airflow characteristics (velocity, turbulence and temperature) around the human body; and (ii) to examine the pollution distribution within the human convective boundary layer (CBL) and personal exposure to gaseous and particulate pollutants as a function of the factors that influence the human CBL, and of different locations of the pollution sources. In this work, the empirical results were obtained primarily by using a thermal manikin to simulate a human in the indoor environment. In spaces with low air mixing, an increase of the ambient temperature from 20 to 26 ̊C widened the CBL flow in front of a seated manikin, but did not influence the shape of the CBL in front of a standing manikin. The same temperature increase caused a reduction of the peak velocity from 0.24 to 0.16 m/s in front of the seated manikin. Dressing the nude manikin in a thin-tight clothing ensemble reduced the peak velocity in the breathing zone by 17%, and by 40% for a thick-loose ensemble. A lack of hair on the head increased the peak velocity from 0.17 to 0.187 m/s. Apart from their thermal insulation, clothing and chair design had a minor influence on the velocity profile beyond 5 cm distance from the body. Closing the gap between the table and the manikin reduced the peak velocity from 0.17 to 0.111 m/s. At a room air temperature of 23 ̊C, with the manikin leaning backwards the peak velocity was 0.185 m/s, which is 45% above the case with the manikin leaning forward. The direction and magnitude of the surrounding airflows considerably influence the airflow distribution around the human body. Downward flow with a velocity of 0.175 m/s at a room air temperature of 23 ̊C did not influence the convective flow in the breathing zone, while the flow at 0.30 m/s affected the CBL at the nose level, reducing the peak velocity from 0.185 to 0.10 m/s. In order to completely break away the human CBL, downward flow had to be supplied with a velocity of 0.425 m/s. Transverse horizontal flow disturbed the CBL at the breathing zone even at 0.175 m/s. With a seated manikin exposed to airflow from below with a velocity of 0.30 and 0.425 m/s assisting the CBL, the peak velocity in the breathing zone was reduced and the flow pattern around the body was affected, compared to the assisting flow of 0.175 m/s or quiescent conditions. In this case, the airflow interaction was strongly affected by the presence of the chair. The results also show that Particle Image Velocimetry (PIV) and Pseudo Color Visualization (PCV) techniques can be adequately employed for the human CBL investigation. The results show that reducing the room air temperature from 23 to 20 ̊C increased the fluctuations of air temperature close to the surface of the body. Large standard deviation of air temperature fluctuations, up to 1.2 ̊C, was easured in the region of the chest, and up to 2.9 ̊C when the exhalation was applied. Leaning the manikin backwards increased the air temperature and standard deviation of air temperature fluctuations in the breathing zone, while a forward body inclination had the opposite effect. Exhalation through the mouth created a steady temperature drop with increasing distance from the mouth, without disturbing conditions in the region of the chest. Exhalation through the nose did not affect the air temperature in front of the chest due to the physics of the jets flow from the nose. Only very small discrepancies between the results obtained with the breathing thermal manikin and a real human subject were found. This suggests that the thermal manikin can be used for accurate measurements of an occupant’s thermal microenvironment. The results also suggest that a detailed understanding of the distribution of pollutants in the vicinity of a human body is essential for understanding exposure in spaces with low air mixing. The pollution source location had a considerable influence on the pollution concentrations measured in the breathing zone and on the extent to which the pollution spread to the surroundings. The highest breathing zone concentrations were measured when the pollution source was located at the chest, while there was negligible exposure to any the pollution emitted from the upper back or behind the chair. Based on the results obtained in a single plane, it was shown that a decrease in personal exposure to pollutants released from or around the human body increased the extent to which the pollution spread to the surroundings. Reduced room air temperature and backward body inclination both intensified the transport of pollution to the breathing zone and increased personal exposure. The front edge of a table positioned at zero distance from the human body reduced pollution/clean air transport to the breathing zone, but when it was positioned 10 cm from the body it increased the transport of pollution/clean air from beneath. For accurate predictions of personal exposure, the characteristics of the CBL must be considered, as it can transport pollution around the human body. The best way to control and reduce personal exposure when the pollution originates at the feet is to employ transverse flow from in front and from the side, relative to the exposed occupant. Airflows from above opposing the CBL and from behind transverse to the CBL, create the most unfavourable velocity field that exhibits a nonlinear dependence between the supply airflow rate and personal exposure. Without a better understanding of the airflow patterns in a room the ventilation rate may therefore be increased in vain.

[1]  Arsen Krikor Melikov,et al.  Exposure of health care workers and occupants to coughed airborne pathogens in a double-bed hospital patient room with overhead mixing ventilation , 2012, HVAC&R Research.

[2]  P V Nielsen,et al.  Role of ventilation in airborne transmission of infectious agents in the built environment - a multidisciplinary systematic review. , 2007, Indoor air.

[3]  S. Kato,et al.  CFD Analysis of a Thermal Plume and the Indoor Air Flow Using k-ε Models with Buoyancy Effects , 2000 .

[4]  Arsen Krikor Melikov,et al.  AIR TEMPERATURE FLUCTUATIONS IN ROOMS , 1997 .

[5]  A. Melikov,et al.  Experimental investigation of the human convective boundary layer in a quiescent indoor environment , 2014 .

[6]  B Fletcher,et al.  Air movement around a worker in a low-speed flow field. , 1996, The Annals of occupational hygiene.

[7]  K W Tham,et al.  Human convection flow in spaces with and without ventilation: personal exposure to floor-released particles and cough-released droplets. , 2015, Indoor air.

[8]  Rasmus Lund Jensen,et al.  Experiments on the Microenvironment and Breathing of a Person in Isothermal and Stratified Surroundings , 2009 .

[9]  Andrea R. Ferro,et al.  Walking-induced particle resuspension in indoor environments , 2014 .

[10]  H. Holmgren,et al.  Relation between humidity and size of exhaled particles. , 2011, Journal of aerosol medicine and pulmonary drug delivery.

[11]  Mark N. Glauser,et al.  On Particle Image Velocimetry (PIV) measurements in the breathing zone of a thermal breathing manikin , 2005 .

[12]  A. Melikov,et al.  Human convective boundary layer and its interaction with room ventilation flow. , 2015, Indoor air.

[13]  A. Melikov,et al.  Transport of gaseous pollutants by convective boundary layer around a human body , 2015 .

[14]  A. Melikov,et al.  Exposure of health care workers and occupants to coughed air in a hospital room with displacement air distribution: impact of ventilation rate and distance from coughing patient , 2012 .

[15]  Henrik Brohus,et al.  Personal Exposure in Displacement Ventilated Rooms , 1996 .

[16]  A. Hubbard,et al.  Toward Understanding the Risk of Secondary Airborne Infection: Emission of Respirable Pathogens , 2005, Journal of occupational and environmental hygiene.

[17]  Magnus Mattsson,et al.  Displacement Ventilation: effects of movement and exhalation , 1997 .

[18]  A. Melikov,et al.  Displacement ventilation - Airflow in the near zone , 1990 .

[19]  J. Samet,et al.  Ventilation rates and health: multidisciplinary review of the scientific literature. , 2011, Indoor air.

[20]  Kerrie Mengersen,et al.  Size distribution and sites of origin of droplets expelled from the human respiratory tract during expiratory activities , 2009 .

[21]  D. Rim,et al.  Transport of particulate and gaseous pollutants in the vicinity of a human body , 2009 .

[22]  G. Settles,et al.  A schlieren optical study of the human cough with and without wearing masks for aerosol infection control , 2009, Journal of The Royal Society Interface.

[23]  Hao Jiang,et al.  Bed with Integrated Personalized Ventilation for Minimizing Cross Infection , 2007 .

[24]  Arsen Krikor Melikov,et al.  Seat headrest-incorporated personalized ventilation: Thermal comfort and inhaled air quality , 2012 .

[25]  Goodarz Ahmadi,et al.  Computational modeling of effects of thermal plume adjacent to the body on the indoor airflow and particle transport , 2012 .

[26]  Brian H. Green,et al.  Office Seating Behaviors an Investigation of Posture, Task, and Job Type , 2001 .

[27]  M. Byrne,et al.  A study of the size distribution of aerosol particles resuspended from clothing surfaces , 2014 .

[28]  A. Melikov,et al.  Air temperature investigation in microenvironment around a human body , 2015 .

[29]  C. Beggs,et al.  The Airborne Transmission of Infection in Hospital Buildings: Fact or Fiction? , 2003 .

[30]  Gary S. Settles,et al.  A Computational and Experimental Investigation of the Human Thermal Plume , 2005 .

[31]  W. J. Mitchell,et al.  Airflow Around a Child-Size Manikin in a Low-Speed Wind Environment , 2003 .

[32]  Arsen Krikor Melikov,et al.  Air Quality and Thermal Comfort in an Office with Underfloor, Mixing and Displacement Ventilation , 2006 .

[33]  Bin Zhao,et al.  Numerical study of the transport of droplets or particles generated by respiratory system indoors , 2004, Building and Environment.

[34]  Chandra Sekhar,et al.  Computational fluid dynamics study and evaluation of different personalized exhaust devices , 2013 .

[35]  J. Räisänen,et al.  Contaminant dispersion in the vicinity of a worker in a uniform velocity field. , 2000, The Annals of occupational hygiene.

[36]  A. Melikov,et al.  Performance of “ductless” personalized ventilation in conjunction with displacement ventilation: Impact of disturbances due to walking person(s) , 2010 .

[37]  Arsen Melikov,et al.  Breathing thermal manikins for indoor environment assessment: important characteristics and requirements , 2004, European Journal of Applied Physiology.

[38]  A. Eisner,et al.  On the Impact of the Human (Child) Microclimate on Passive Aerosol Monitor Performance , 2002 .

[39]  M. Sandberg,et al.  Building Ventilation: Theory and Measurement , 1996 .

[40]  A. Maynard,et al.  A survey of wind speeds in indoor workplaces. , 1998, The Annals of occupational hygiene.

[41]  J. Duguid,et al.  Air infection with dust liberated from clothing. , 1948, Lancet.

[42]  R Ortengren,et al.  Lumbar disc pressure and myoelectric back muscle activity during sitting. 3. Studies on a wheelchair. , 1974, Scandinavian journal of rehabilitation medicine.

[43]  C. Wysocki,et al.  Facts, fallacies, fears, and frustrations with human pheromones. , 2004, The anatomical record. Part A, Discoveries in molecular, cellular, and evolutionary biology.

[44]  E. H. Mathews,et al.  Building and environment—The way forward , 1996 .

[45]  Mark N. Glauser,et al.  Impact of manikin motion on particle transport in the breathing zone , 2010 .

[46]  Chandra Sekhar,et al.  Airflow Dynamics of Human Jets: Sneezing and Breathing - Potential Sources of Infectious Aerosols , 2013, PloS one.

[47]  Mary-Louise McLaws,et al.  The role of particle size in aerosolised pathogen transmission: A review , 2010, Journal of Infection.

[48]  Jovan Pantelic,et al.  Personalized ventilation as a control measure for airborne transmissible disease spread , 2009, Journal of The Royal Society Interface.

[49]  Clara Marika Velte,et al.  Airflow Characteristics At The Breathing Zone of a Seated Person: Interaction of the Free Convection Flow and an Assisting Locally Supplied Flow From Below for Personalized Ventilation Application , 2011 .

[50]  Chao-Hsin Lin,et al.  Flow dynamics and characterization of a cough. , 2009, Indoor air.

[51]  Matthias Kühn,et al.  Feasibility Study of Tomographic Particle Image Velocimetry for Large Scale Convective Air Flow , 2007 .

[52]  K. Mengersen,et al.  Characterization of expiration air jets and droplet size distributions immediately at the mouth opening , 2008, Journal of Aerosol Science.

[53]  Shinhao Yang,et al.  The size and concentration of droplets generated by coughing in human subjects. , 2007, Journal of aerosol medicine : the official journal of the International Society for Aerosols in Medicine.

[54]  P V Nielsen,et al.  Dispersal of exhaled air and personal exposure in displacement ventilated rooms. , 2002, Indoor air.

[55]  S. Sattar,et al.  Survival characteristics of airborne human coronavirus 229E. , 1985, The Journal of general virology.

[56]  D. Rim,et al.  Occupational Exposure to Hazardous Airborne Pollutants: Effects of Air Mixing and Source Location , 2010, Journal of occupational and environmental hygiene.

[57]  Qingyan Chen,et al.  Flow and contaminant transport in an airliner cabin induced by a moving body: Model experiments and CFD predictions , 2010 .