Image-Based Mechanical Analysis of Stent Deformation: Concept and Exemplary Implementation for Aortic Valve Stents

An approach for extracting the radial force load on an implanted stent from medical images is proposed. To exemplify the approach, a system is presented which computes a radial force estimation from computer tomography images acquired from patients who underwent transcatheter aortic valve implantation (TAVI). The deformed shape of the implanted valve prosthesis' Nitinol frame is extracted from the images. A set of displacement vectors is computed that parameterizes the observed deformation. An iterative relaxation algorithm is employed to adapt the information extracted from the images to a finite-element model of the stent, and the radial components of the interaction forces between the stent and the tissue are extracted. For the evaluation of the method, tests were run using the clinical data from 21 patients. Stent modeling and extraction of the radial forces were successful in 18 cases. Synthetic test cases were generated, in addition, for assessing the sensitivity to the measurement errors. In a sensitivity analysis, the geometric error of the stent reconstruction was below 0.3 mm, which is below the image resolution. The distribution of the radial forces was qualitatively and quantitatively reasonable. An uncertainty remains in the quantitative evaluation of the radial forces due to the uncertainty in defining a radial direction on the deformed stent. With our approach, the mechanical situation of TAVI stents after the implantation can be studied in vivo, which may help to understand the mechanisms that lead to the complications and improve stent design.

[1]  Silvia Schievano,et al.  Computational studies of shape memory alloy behavior in biomedical applications. , 2005, Journal of biomechanical engineering.

[2]  G. Latsios,et al.  VALVULAR AND STRUCTURAL HEART DISEASES Original Studies ‘‘Device Landing Zone’’ Calcification, Assessed by MSCT, as a Predictive Factor for Pacemaker Implantation After TAVI , 2010 .

[3]  H. Van Oosterwyck,et al.  A multi-scale mechanobiological model of in-stent restenosis: deciphering the role of matrix metalloproteinase and extracellular matrix changes , 2014, Computer methods in biomechanics and biomedical engineering.

[4]  S Tzamtzis,et al.  Numerical analysis of the radial force produced by the Medtronic-CoreValve and Edwards-SAPIEN after transcatheter aortic valve implantation (TAVI). , 2013, Medical engineering & physics.

[5]  Thomas Schroeter,et al.  Predictors of permanent pacemaker implantation after Medtronic CoreValve bioprosthesis implantation. , 2012, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[6]  Edoardo Mazza,et al.  Reconstruction of Stent Induced Loading Forces on the Aortic Valve Complex , 2013 .

[7]  R. Guyton,et al.  An Engineering Review of Transcatheter Aortic Valve Technologies , 2010 .

[8]  Antonio Colombo,et al.  Computed tomography-based evaluation of aortic annulus, prosthesis size and impact on early residual aortic regurgitation after transcatheter aortic valve implantation. , 2013, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[9]  Rebecca Fahrig,et al.  In-vivo imaging of femoral artery nitinol stents for deformation analysis. , 2011, Journal of vascular and interventional radiology : JVIR.

[10]  Silvia Schievano,et al.  Finite Element Analysis to Study Percutaneous Heart Valves , 2012 .

[11]  F Auricchio,et al.  Simulation of transcatheter aortic valve implantation: a patient-specific finite element approach , 2014, Computer methods in biomechanics and biomedical engineering.

[12]  G. White,et al.  Evaluation of the risks of using an oversized balloon catheter in the human infrarenal abdominal aorta. , 1998, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[13]  Joseph W Freeman,et al.  A link between stent radial forces and vascular wall remodeling: The discovery of an optimal stent radial force for minimal vessel restenosis , 2010, Connective tissue research.

[14]  David Moratal Finite Element Analysis: From Biomedical Applications To Industrial Developments , 2014 .

[15]  S. Pocock,et al.  Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. , 2010, The New England journal of medicine.

[16]  Wei Sun,et al.  Patient-specific modeling of biomechanical interaction in transcatheter aortic valve deployment. , 2012, Journal of biomechanics.

[17]  Claude Kauffmann,et al.  A Literature Review of the Numerical Analysis of Abdominal Aortic Aneurysms Treated with Endovascular Stent Grafts , 2012, Comput. Math. Methods Medicine.

[18]  Thomas Felderhoff,et al.  First report on a human percutaneous transluminal implantation of a self‐expanding valve prosthesis for interventional treatment of aortic valve stenosis , 2005, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[19]  Garrett J. Hall,et al.  Comparison of element technologies for modeling stent expansion. , 2006, Journal of biomechanical engineering.

[20]  Claudio Chiastra,et al.  Sequential structural and fluid dynamic numerical simulations of a stented bifurcated coronary artery. , 2011, Journal of biomechanical engineering.

[21]  André Plass,et al.  Cubic hermite bezier spline based reconstruction of implanted aortic valve stents from CT images , 2011, 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[22]  Wei Sun,et al.  Quantification of Biomechanical Interaction of Transcatheter Aortic Valve Stent Deployed in Porcine and Ovine Hearts , 2012, Annals of Biomedical Engineering.