Improving long-path differential optical absorption spectroscopy with a quartz-fiber mode mixer.

Long-path differential optical absorption spectroscopy (DOAS) has become an increasingly important method for determination of the concentration of tropospheric trace gases (e.g., O(3), NO(2), BrO, ClO). The use of photodiode array (PDA) detectors enhances long-path DOAS systems considerably owing to PDA's higher sensitivity resulting from the multiplex advantage. The detection limits of these systems are expected to be 1 order of magnitude lower than systems of similar optical setup with scanning detectors. When the scanning detector is simply replaced by a PDA, unwanted spectral structures of as much as 8 x 10(-3) appear. The size of these randomly changing structures exceeds the photon noise level by 2-3 orders of magnitude thus severely limiting the sensitivity. We show that an angular dependence of the response of the PDA causes this structure in combination with unavoidable changes in the illumination. A quartz-fiber mode mixer, which makes the illumination of the spectrograph-detector system nearly independent of the angular intensity distribution of the measured light, was developed and tested. This new device reduces the unwanted structures in laboratory and field experiments by a factor of 10. The detection limits of long-path DOAS instruments with PDA detectors are improved by the same amount and are thus lower than those of currently used systems with scanning detectors. At the same time a much shorter measurement time (by ~1 order of magnitude) becomes possible.

[1]  D. Marcuse,et al.  Coupled mode theory of round optical fibers , 1973 .

[2]  Toshimitsu Asakura,et al.  Evaluation of the mode scrambler characteristics in terms of the speckle contrast , 1979 .

[3]  John M. C. Plane,et al.  Differential optical absorption spectrometer for measuring atmospheric trace gases , 1992 .

[4]  Joseph Reader,et al.  Optimizing Czerny–Turner Spectrographs: A Comparison between Analytic Theory and Ray Tracing , 1969 .

[5]  H. Dorn,et al.  A New In Situ Laser Long-Path Absorption Instrument for the Measurement of Tropospheric OH Radicals , 1995 .

[6]  U. Platt,et al.  Numerical analysis and estimation of the statistical error of differential optical absorption spectroscopy measurements with least-squares methods. , 1996, Applied optics.

[7]  G. Mount,et al.  Interference effects in reticon photodiode array detectors. , 1992, Applied optics.

[8]  U. Platt,et al.  Detection of nitrous acid in the atmosphere by differential optical absorption , 1979 .

[9]  U. Platt,et al.  An instrument for the spectroscopic measurement of trace substances in the atmosphere , 1984 .

[10]  Ulrich Platt,et al.  Detection of NO3 in the polluted troposphere by differential optical absorption , 1980 .

[11]  M. Hausmann,et al.  Spectroscopic measurement of bromine oxide and ozone in the high Arctic during Polar Sunrise Experiment 1992 , 1994 .

[12]  Ulrich Platt,et al.  OH ‐ Radicals in the lower troposphere , 1976 .

[13]  W. Kiefer,et al.  Improving Spectroscopic Techniques by a Scanning Multichannel Method , 1990 .

[14]  M Hausmann,et al.  Improvement of differential optical absorption spectroscopy with a multichannel scanning technique. , 1995, Applied optics.

[15]  R. McKenzie,et al.  Long‐path absorption measurements of tropospheric NO2 in rural New Zealand , 1984 .