Effect of Spandrel Beam to Double Tee Connection Characteristic on Flexure-Controlled Precast Diaphragms

Precast spandrel beams are often used on the perimeter of precast buildings to support the precast floor units. These elements are typically not considered part of the lateral force resisting system. However, the presence of the spandrel beams in the floor system may modify the strength, stiffness, and deformation capacity of the precast floor diaphragm. The nature of this response is highly dependent on the characteristics of the details connecting the spandrel to the precast floor system. These details are often welded connections used primarily for erection stability and designed without diaphragm action in mind. With emerging design methodologies for precast diaphragms requiring better-defined performance, the impact of the spandrel beams must be accounted for. Accordingly, analytical research is presented here that examines the effect of spandrel-beam-connecting details on the global characteristics and local demands of a flexure-controlled precast floor diaphragm. Design recommendations are provided.

[1]  Robert B. Fleischman,et al.  Appropriate Overstrength of Shear Reinforcement in Precast Concrete Diaphragms , 2007 .

[2]  Andrea Belleri,et al.  Preliminary results of the shake-table testing for the development of a diaphragm seismic design methodology , 2009 .

[3]  Michael G. Oliva,et al.  Tests on double tee flange connectors subjected to monotonic and cyclic loading , 1998 .

[4]  Donald F. Meinheit,et al.  Design criteria for headed stud groups in shear : Part 1 - Steel capacity and back edge effects , 2000 .

[5]  Robert B. Fleischman,et al.  EFFECT OF DIMENSION AND DETAIL ON THE CAPACITY OF PRECAST CONCRETE PARKING STRUCTURE DIAPHRAGMS , 2003 .

[6]  Ho Jung Lee,et al.  Seismic response of parking structures with precast concrete diaphragms , 2008 .

[7]  John F. Stanton,et al.  NEW SEISMIC DESIGN PROVISIONS FOR DIAPHRAGMS IN PRECAST CONCRETE PARKING STRUCTURES , 2000 .

[8]  Basile G. Rabbat,et al.  Notes on ACI 318-08, building code requirements for structural concrete : with design applications , 2008 .

[9]  Neil M. Hawkins,et al.  Performance of precast/prestressed concrete building structures during Nirthridge earthquake , 1994 .

[10]  A. Fattah Shaikh,et al.  Load Testing of a Precast Concrete Double-Tee Flange Connector , 2004 .

[11]  Clay Naito,et al.  Development of a Seismic Design Methodology for Precast Diaphragms - PHASE 1 SUMMARY REPORT , 2006 .

[12]  José I. Restrepo,et al.  Earthquake‐induced floor horizontal accelerations in buildings , 2002 .