Comparison of Filter and Wall Deposits From Samplers Used to Collect Airborne Lead-Containing Dusts at Field Sites

Pairs of Institute of Occupational Medicine (IOM) and 37 mm closed face cassette samplers (CFC) were deployed where occupational exposures to lead-containing dusts were known to occur. Discrete particle analyses of wall and filter deposits were performed by Scanning Electron Microscopy—Energy Dispersive X-ray Spectrometry (SEM-EDX). From the elemental composition and projected area diameter of each particle a density, volume, and mass were calculated, and a mass-weighted size distribution for each filter and corresponding wall deposit determined. Comparison of pairs of wall and filter mass-weighted size distributions by Mann–Whitney statistical analysis shows that in only 3 of 72 examples from either sampler were the distributions significantly different that suggests that the mechanisms of particle deposition on the sampler walls for particles in this size range (0.5 μm through 20 μm) do not differ for the different samplers. Furthermore, in only 4 of 33 sampler pairs did the IOM and CFC results differ. Although these results originate from several distinct processes characterized by different chemical and physical dust generation mechanisms, they suggest that in these environments the measurement of “total dust” by the CFC and inhalable dust by the IOM will be very similar when both samplers are processed the same way with respect to the including or excluding wall deposits with the filter catch. However, these results may not be applicable to environments where larger particles exist.

[1]  H Kromhout,et al.  A collaborative European study of personal inhalable aerosol sampler performance. , 1997, The Annals of occupational hygiene.

[2]  S N Li,et al.  Evaluation of six inhalable aerosol samplers. , 2000, AIHAJ : a journal for the science of occupational and environmental health and safety.

[3]  R A Botham,et al.  Field comparison of personal samplers for inhalable dust. , 1990, The Annals of occupational hygiene.

[4]  D Mark The use of dust-collecting cassettes in dust samplers. , 1990, The Annals of occupational hygiene.

[5]  Martin Harper,et al.  A comparison of X-ray fluorescence and wet chemical analysis for lead on air filters from different personal samplers used in a bronze foundry. , 2005, Journal of environmental monitoring : JEM.

[6]  Richard Wrobel,et al.  Field comparison of 37-mm closed-face cassettes and IOM samplers. , 2002, Applied occupational and environmental hygiene.

[7]  James E Slaven,et al.  Portable XRF analysis of occupational air filter samples from different workplaces using different samplers: final results, summary and conclusions. , 2007, Journal of environmental monitoring : JEM.

[8]  Martin Harper,et al.  Concerning sampler wall deposits in the chemical analysis of airborne metals. , 2007, Journal of occupational and environmental hygiene.

[9]  Martin Harper,et al.  A comparison of portable XRF and ICP-OES analysis for lead on air filter samples from a lead ore concentrator mill and a lead-acid battery recycler. , 2006, Journal of environmental monitoring : JEM.

[10]  Martin Harper,et al.  A comparison of X-ray fluorescence and wet chemical analysis of air filter samples from a scrap lead smelting operation. , 2004, Journal of environmental monitoring : JEM.

[11]  Martin Harper,et al.  Size Distributions of 0.5 to 20 μm Aerodynamic Diameter Lead-Containing Particles from Aerosol Sampler Walls and Filters , 2009 .

[12]  S C Soderholm,et al.  Aerosol sampling efficiency of 37 mm filter cassettes. , 1986, American Industrial Hygiene Association journal.

[13]  L R Murphy,et al.  Prevention of work-related psychological disorders. A national strategy proposed by the National Institute for Occupational Safety and Health (NIOSH). , 1990, The American psychologist.

[14]  J H Vincent,et al.  Investigation into the impact of introducing workplace aerosol standards based on the inhalable fraction. , 1996, The Analyst.

[15]  M. M. Kilgo,et al.  The Statistical Sleuth: A Course in Methods of Data Analysis , 1998 .

[16]  A. Guha Transport and Deposition of Particles in Turbulent and Laminar Flow , 2008 .

[17]  Martin Harper,et al.  A comparison of X-ray fluorescence and wet chemical analysis for lead on air filters from different personal samplers used in a secondary lead smelter/solder manufacturer. , 2006, Journal of environmental monitoring : JEM.

[18]  R. Nagarajan,et al.  Sampling and Analysis Methods , 2006 .